Methods for the Measurement of Respiratory Rate

NCT ID: NCT02672007

Last Updated: 2016-03-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

50 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-01-31

Study Completion Date

2016-02-29

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study aims to investigate these research questions:

1. Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with a research assistant using a criterion standard approach?
2. Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with hospital staff's current clinical practice?

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Respiratory rate is among the first vital signs to change when a deterioration in patient conditions occurs, and that it is highly useful in identifying high-risk patients, patients in pain, risk of death in patients treated for myocardial infarctions and medical patients at risk of cardiac arrest.

Respiratory rate is one of the seven physiological parameters included in the Early Warning Score (EWS), an aggregated track- and trigger-system for risk-stratification of patients in hospital wards at risk of imminent clinical deterioration. EWS includes an escalation protocol, defining when it is necessary for the ward staff to call for assistance and when vital parameters should be measured again.

Manual measurement of respiratory rates is the standard in hospital wards in the Capital Region of Denmark. During the measurement of respiratory rate, patients ideally have to lie still and refrain from talking. This poses a difficulty in daily, clinical practice. Several studies in hospital wards both using and not using an EWS-system report that respiratory rate is often omitted when vital signs are measured.

Even if the respiratory rate is measured regularly, poor inter-observer agreement and reproducibility of measured respiratory rates have been found. Respiratory rates recorded by nurses have been reported to be generally higher than those measured by observers using a standardised approach.

The EWS currently in use is validated using measurements obtained by normal nursing practise. If there is an element of human influence on the measurement of respiratory rate, automation could affect the prognostic properties of EWS in an unpredictable way, even if the automatically measured respiratory rates more reliably reflect the patients' physiology than current clinical practise.

If a systematic difference between the recordings by staff and the electronic devices currently on the market exists, this could have an implication on the EWS scores and subsequently, escalation protocols for patients with elevated EWS could be affected. If this is the case, EWS might even have to be re-validated using machine-measured respiratory rates.

Thus, even as there could be a number of advantages of automating the measurements of respiratory rates in hospital wards, due considerations are required before ward staff's manual measurement of respiratory rate can be replaced by measurements obtained from electronic devices. The purpose of this study is to evaluate if there is a systematic difference in the respiratory rate measurements performed by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with the measurements performed by a research assistant using a criterion standard approach and the ward staff's usual measurements.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Respiratory Rate Measurement Methods.

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Included patients

All included patients will have respiratory rates measured by a research assistant using a criterion standard approach, by the SensiumVitals device and by the ward staff.

Group Type OTHER

SensiumVitals

Intervention Type DEVICE

The patients will have their respiratory rates, heart rates and temperature (axilla) measured continuously by the SensiumVitals patch.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

SensiumVitals

The patients will have their respiratory rates, heart rates and temperature (axilla) measured continuously by the SensiumVitals patch.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age 18 years or older.
* Able and willing to give informed consent to participation in the study and necessary data collection.
* Admitted to the general medical short-time ward and planned stay there at the time of inclusion greater than two hours.

Exclusion Criteria

* Wounds, burns or other conditions that prevent proper attachment of the measurement device, or where wearing the device might cause or increase discomfort from wearing the device.
* Allergies to medical graded tape or ECG electrodes.
* Patients with cardiac pacemaker or implanted defibrillator.
* Any condition or situation preventing proper information, consent and enrolment.
* Respiratory rate measurements by another device using impedance pneumography.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Herlev Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Niels Egholm Pedersen

MD, PhD student

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Niels E Pedersen, MD

Role: PRINCIPAL_INVESTIGATOR

Copenhagen Academy for Medical Education and Simulation, Herlev Hospital, Center for HR, Capital Region of Denmark

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Copenhagen Academy for Medical Education and Simulation and Medical-Short Time Ward, Herlev Hospital

Herlev, Herlev, Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CAMES-16-001

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Ventilation Monitoring in OHCA
NCT04988906 COMPLETED NA
The PneumoRator Study
NCT07293299 RECRUITING