Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
1000 participants
INTERVENTIONAL
2015-12-31
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
To perform a CAG/PCI, a tube (a so-called sheath) has to be inserted in a. radialis. It is unclear whether the design of the sheaths can reduce the spasm tendency, thus reducing pain. Terumo has recently introduced a new kind of sheath, so-called Terumo Glide Slender Heath Coated (hereafter referred to as "Slender sheath"). This sheath is partly coated, partly made of a thinner material. "Slender sheath" thus has an outer diameter smaller than that of the sheath from traditional use (Terumo Radio Focus sheath, hereafter referred to as "Standard sheath"), although the inner diameter (lumen) is the same in the two sheaths. In turn, the "Slender sheath" is more fragile and far more expensive.
The purpose of the present study is to evaluate whether use of slender sheath compared with standard sheath is Associated with less pain and fewer complications following CAG/PCI.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Use of Glidesheath Slender to Reduce Radial Artery Occlusion and Vascular Access Site Complications Following Transradial Coronary Angiography
NCT02324764
GlideSheath Slender® Versus Conventional 5Fr Arterial Sheath in Coronary Angiography Through the Distal Radial Artery
NCT04911218
Oximetry Guided Versus Traditional Rapid Deflation Technique for Achieving Hemostasis After Radial Procedures
NCT03626129
RADIAL Versus Femoral Access for Coronary Artery Bypass Graft Angiography and Intervention (RADIAL-CABG) Trial
NCT01446263
Comparison of Distal and Proximal Radial Artery Patency Following Coronary Catheterization, A Real Look at a Special Community
NCT07138170
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Purposes: to investigate whether the use of "Slender sheath" is associated with less pain compared to use of "Standard Sheath" and less complications corresponding at the access site. Specific hypotheses:
1. Use of "Slender sheath" results in less pain related to CAG/PCI compared to use of "Standard sheath".
2. Use of "Slender sheath" is associated with fewer conversions to femoral access compared to use of "Standard sheath".
3. Use of "Slender sheath" is associated with less use of analgesic during the procedure compared to use of "Standard sheath".
4. Use of "Slender sheath" is associated with fewer cases of occlusion of a. radialis at discharge and post-examination compared to use of "Standard sheath".
Time Schedule The trial will run from December 2015 until a total number of 1000 patients are included. It is expected that the data collection and publication of the results will be completed within a year.
Endpoints
1. Pain related to the application of the sheath (Visual Analog Scale = VAS)
2. Maximal pain during CAG/PCI (VAS)
3. Frequency of conversions to femoral access
4. Use of analgesics (cumulative amount of mg Fentanyl given)
5. Use of sedatives (cumulative amount of mg Midazolam given)
6. Use of Verapamil (cumulative amount of mg given, used to reduce spasms)
7. Number of catheters used
8. Number of sheaths used (femoral and radial)
9. Occlusion of a. radialis at the time of discharge estimated by ultrasound of the artery
10. Occlusion of a. radialis after a month (Assumes that all patients with open vessels at discharge also have open vessels after a month. Only patients with occluded vessels at discharge will be offered a new ultrasound scan)
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
DIAGNOSTIC
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Slender arm
Uses the terumo slender sheath for radial angiography or angioplasty
Slender Sheath
Comparing outcomes for two different sheaths used during radial CAG/PCI
Standard arm
Uses the terumo standard sheath (Routine) for radial angiography or angioplasty
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Slender Sheath
Comparing outcomes for two different sheaths used during radial CAG/PCI
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Able to give written informed consent
Exclusion Criteria
* Use of 8F catheters
18 Years
100 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Aarhus University Hospital Skejby
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Christian Juhl Terkelsen
MD, DmSc, Associate professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of cardiology, Aarhus University Hospital in Skejby
Aarhus, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ACCESS-I
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.