Treatment of Saphenous Vein Reflux With 1920-nm Diode Laser

NCT ID: NCT02504684

Last Updated: 2015-07-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

67 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-02-28

Study Completion Date

2015-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Objective: Compare venous occlusion rates at a one-year follow-up comparing 1920-nm versus 1470-nm laser treatment. Design: Non-randomized prospective study. Methods: Adult patients with varicose veins associated with great saphenous reflux were included. Procedures were performed between February and April of 2013. The 1470-nm laser ablation was performed in continuous mode, power being set between 8 and 10 W, while for the 1920-nm it was set between 5 and 6 W. Checking for vein closure was performed during the thermal ablation procedure, LEED (linear endovenous energy density) being calculated after the procedure. Follow-up data were collected at the 7-day, 30-day, 3-month, 6-month and 1-year visits, and involved clinical and ultrasound evaluation, measurement of occlusion extent.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

INTRODUCTION The treatment of varicose veins secondary to saphenous vein reflux has undergone a major shift in the past decade, primarily led by the introduction of less invasive techniques. Wavelengths of 810, 940 and 980 nm have higher rates of absorption by hemoglobin. Water chromophore is associated with an initial energy absorption peak at 980 nm, followed by peaks at 1500 and 2000 nm. The energy released into the vein lumen is therefore absorbed by water as well as by cellular and interstitial proteins. In contrast, laser beams with longer wavelengths act more specifically on water absorbance, resulting in less energy expenditure, such as in the case of the 1470-nm diode endolaser. An endoluminal energy density (LEED) around 50-160 J/cm has been demonstrated to effectively lead to venous occlusion, although LEEDs above 100 J/cm can also be associated with higher complication rates. In contrast, the 1920-nm diode laser is more specific for water and hemoglobin chromophores, tissue absorption at this wavelength being at least 2.5 times greater than the one obtained with the 1470-nm laser. It is therefore expected that less energy would be required to generate the same amount of venous closure.

The aim of this study is to compare diode 1920-nm versus 1470-nm laser in the treatment of great saphenous vein reflux. The primary outcome was venous segment occlusion at the one-year follow-up. Secondary outcomes included LEED, postoperative complications, and clinical outcomes measured through the Clinical, Etiology, Anatomical and Pathological classification (CEAP), the Venous Clinical Severity Score (VCSS) and a patient satisfaction scale.

METHODS This is a prospective study to evaluate the results of the 1920-nm vs. 1470-nm laser. Patients agreeing to participate were offered informed consent, recruitment occurring between February and April of 2013. Participants enrolled between February and mid-March of 2013 underwent treatment with the 1470-nm laser, while those enrolled between mid-March and April underwent treatment with the 1920-nm laser.

Patients between 18 and 70 years old who had varicose veins associated with reflux of the great saphenous veins were included. The exclusion criteria were: patients with a previous history of thrombophlebitis, deep vein thrombosis or who had undergone any previous surgery for this condition, thermal ablation or sclerotherapy. For bilateral cases, both limbs were treated during the same surgical session.

Data on clinical history, physical examination, CEAP classification, VCSS (Venous Clinical Severity Score) and VDS (Venous Disability Score) were collected. The extent of the great saphenous reflux was measured along with its main diameter at the level of the saphenofemoral junction as well as at the knee level. Reflux was defined as retrograde when reaching a speed greater than 3 cm/second during a Valsalva maneuver or through leg compression maneuvers.

All patients underwent procedures under spinal anesthesia. The great saphenous vein was punctured at the most distal point of reflux and a 6F introducer was positioned. All cases were conducted with a 600-micron radial fiber positioned between 2.0 and 3.0 cm from the saphenofemoral junction. A tumescence with 0.9% saline solution was placed under ultrasound guidance around the full length of the saphenous vein. All patients were in a 30-degree Trendelenburg position. Surgical procedures involved the saphenous ablation and phlebectomy.

Saphenous ablation with a 1470-nm laser was performed in continuous mode, with a power of 8 to 10 W, determined as a function of the diameter of the vessel as well as surgeon's preference. The 1920-nm laser was also used in continuous mode, with 5 to 6 W power. Vein closure monitoring during the thermal ablation procedure was conducted through ultrasound while pulling-off the fiber. At the end of the procedure, the total amount of energy used in each limb was recorded for LEED calculation, measured as total energy used in the limb (J) over vein length (cm).

First follow-up occurred at postoperative week one, with subsequent evaluation at 30 days, three months, six months and one year. At each assessment, symptoms were recorded and an ultrasound evaluation was performed. Patient satisfaction was evaluated at 1-week through the following questions "Are you satisfied with your surgery?" and "Would you choose the same treatment again?" Both questions were presented as a Likert scale where 0 = very satisfied, 1 = satisfied, 2 = indifferent, 3 = not satisfied, 4 = very dissatisfied.

The primary endpoint for this study was the percentage of occluded venous segments at the 6-month follow-up. Extension of the occluded saphenous vein segment was measured at each visit through a tape guided by ultrasound to determine occlusion points. A segment was considered patent if it was compressible and with reflux after muscle compression in a standing position. The length of the occluded vein segment was compared with the length of the segment where thermal ablation was performed, thus allowing us to calculate the segment closure percentage. Secondary end-points were the presence of ecchymosis, induration, paresthesia, skin burns and deep vein thrombosis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Varicose Veins

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

1470-nm

Endovenous 1470-nm diode laser

Group Type ACTIVE_COMPARATOR

Endovenous 1470-nm diode laser

Intervention Type DEVICE

Patients with saphenous veins treated with the standard 1470-nm diode endolaser.

1920-nm Group

Endovenous 1920-nm diode laser

Group Type EXPERIMENTAL

Endovenous 1920-nm diode laser

Intervention Type DEVICE

Patients with saphenous veins treated with a new 1920-nm diode endolaser.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Endovenous 1920-nm diode laser

Patients with saphenous veins treated with a new 1920-nm diode endolaser.

Intervention Type DEVICE

Endovenous 1470-nm diode laser

Patients with saphenous veins treated with the standard 1470-nm diode endolaser.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

1920-nm laser 1470-nm laser

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients with varicose veins associated with reflux of great or small saphenous veins

Exclusion Criteria

* Patients under 18 years old or over 70 years.
* Acute or previous thrombophlebitis or deep vein thrombosis.
* Pregnant patient.
Minimum Eligible Age

18 Years

Maximum Eligible Age

70 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Instituto Vascular BH

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Daniel Mendes Pinto

Daniel Mendes Pinto, MD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Daniel M Pinto, MD

Role: PRINCIPAL_INVESTIGATOR

Instituto Vascular BH

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Children ABC hospital

Belo Horizonte, Minas Gerais, Brazil

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Brazil

References

Explore related publications, articles, or registry entries linked to this study.

Rasmussen LH, Lawaetz M, Bjoern L, Vennits B, Blemings A, Eklof B. Randomized clinical trial comparing endovenous laser ablation, radiofrequency ablation, foam sclerotherapy and surgical stripping for great saphenous varicose veins. Br J Surg. 2011 Aug;98(8):1079-87. doi: 10.1002/bjs.7555.

Reference Type RESULT
PMID: 21725957 (View on PubMed)

Siribumrungwong B, Noorit P, Wilasrusmee C, Attia J, Thakkinstian A. A systematic review and meta-analysis of randomised controlled trials comparing endovenous ablation and surgical intervention in patients with varicose vein. Eur J Vasc Endovasc Surg. 2012 Aug;44(2):214-23. doi: 10.1016/j.ejvs.2012.05.017. Epub 2012 Jun 15.

Reference Type RESULT
PMID: 22705163 (View on PubMed)

Pan Y, Zhao J, Mei J, Shao M, Zhang J. Comparison of endovenous laser ablation and high ligation and stripping for varicose vein treatment: a meta-analysis. Phlebology. 2014 Mar;29(2):109-19. doi: 10.1177/0268355512473911. Epub 2013 May 6.

Reference Type RESULT
PMID: 23390218 (View on PubMed)

Vuylsteke ME, Vandekerckhove PJ, De Bo T, Moons P, Mordon S. Use of a new endovenous laser device: results of the 1,500 nm laser. Ann Vasc Surg. 2010 Feb;24(2):205-11. doi: 10.1016/j.avsg.2009.06.024. Epub 2009 Sep 11.

Reference Type RESULT
PMID: 19748212 (View on PubMed)

von Hodenberg E, Zerweck C, Knittel M, Zeller T, Schwarz T. Endovenous laser ablation of varicose veins with the 1470 nm diode laser using a radial fiber - 1-year follow-up. Phlebology. 2015 Mar;30(2):86-90. doi: 10.1177/0268355513512825. Epub 2013 Nov 29.

Reference Type RESULT
PMID: 24291781 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

20130220

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The BRILLIANT Study
NCT00618514 TERMINATED NA