Treatment of Saphenous Vein Reflux With 1920-nm Diode Laser
NCT ID: NCT02504684
Last Updated: 2015-07-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
67 participants
INTERVENTIONAL
2013-02-28
2015-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Endovenous Radiofrequency Versus Laser Ablation for the Treatment of Great Saphenous Vein Reflux
NCT02080013
Clinical Trial of Endovenous 940 and 1470 Laser Ablation for Treating Great Saphenous Veins
NCT01637181
Safety Distance for Endovenous Laser Ablation of the Great Saphenous Vein
NCT03946644
Study on Treatment of Varicose Veins by Endovenous Laser (1940 nm vs 1470 nm)
NCT05663359
Retrospective Review of Saphenous Vein Incompetence: Venaseal Versus Endovenous Thermal Ablation
NCT04006184
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The aim of this study is to compare diode 1920-nm versus 1470-nm laser in the treatment of great saphenous vein reflux. The primary outcome was venous segment occlusion at the one-year follow-up. Secondary outcomes included LEED, postoperative complications, and clinical outcomes measured through the Clinical, Etiology, Anatomical and Pathological classification (CEAP), the Venous Clinical Severity Score (VCSS) and a patient satisfaction scale.
METHODS This is a prospective study to evaluate the results of the 1920-nm vs. 1470-nm laser. Patients agreeing to participate were offered informed consent, recruitment occurring between February and April of 2013. Participants enrolled between February and mid-March of 2013 underwent treatment with the 1470-nm laser, while those enrolled between mid-March and April underwent treatment with the 1920-nm laser.
Patients between 18 and 70 years old who had varicose veins associated with reflux of the great saphenous veins were included. The exclusion criteria were: patients with a previous history of thrombophlebitis, deep vein thrombosis or who had undergone any previous surgery for this condition, thermal ablation or sclerotherapy. For bilateral cases, both limbs were treated during the same surgical session.
Data on clinical history, physical examination, CEAP classification, VCSS (Venous Clinical Severity Score) and VDS (Venous Disability Score) were collected. The extent of the great saphenous reflux was measured along with its main diameter at the level of the saphenofemoral junction as well as at the knee level. Reflux was defined as retrograde when reaching a speed greater than 3 cm/second during a Valsalva maneuver or through leg compression maneuvers.
All patients underwent procedures under spinal anesthesia. The great saphenous vein was punctured at the most distal point of reflux and a 6F introducer was positioned. All cases were conducted with a 600-micron radial fiber positioned between 2.0 and 3.0 cm from the saphenofemoral junction. A tumescence with 0.9% saline solution was placed under ultrasound guidance around the full length of the saphenous vein. All patients were in a 30-degree Trendelenburg position. Surgical procedures involved the saphenous ablation and phlebectomy.
Saphenous ablation with a 1470-nm laser was performed in continuous mode, with a power of 8 to 10 W, determined as a function of the diameter of the vessel as well as surgeon's preference. The 1920-nm laser was also used in continuous mode, with 5 to 6 W power. Vein closure monitoring during the thermal ablation procedure was conducted through ultrasound while pulling-off the fiber. At the end of the procedure, the total amount of energy used in each limb was recorded for LEED calculation, measured as total energy used in the limb (J) over vein length (cm).
First follow-up occurred at postoperative week one, with subsequent evaluation at 30 days, three months, six months and one year. At each assessment, symptoms were recorded and an ultrasound evaluation was performed. Patient satisfaction was evaluated at 1-week through the following questions "Are you satisfied with your surgery?" and "Would you choose the same treatment again?" Both questions were presented as a Likert scale where 0 = very satisfied, 1 = satisfied, 2 = indifferent, 3 = not satisfied, 4 = very dissatisfied.
The primary endpoint for this study was the percentage of occluded venous segments at the 6-month follow-up. Extension of the occluded saphenous vein segment was measured at each visit through a tape guided by ultrasound to determine occlusion points. A segment was considered patent if it was compressible and with reflux after muscle compression in a standing position. The length of the occluded vein segment was compared with the length of the segment where thermal ablation was performed, thus allowing us to calculate the segment closure percentage. Secondary end-points were the presence of ecchymosis, induration, paresthesia, skin burns and deep vein thrombosis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1470-nm
Endovenous 1470-nm diode laser
Endovenous 1470-nm diode laser
Patients with saphenous veins treated with the standard 1470-nm diode endolaser.
1920-nm Group
Endovenous 1920-nm diode laser
Endovenous 1920-nm diode laser
Patients with saphenous veins treated with a new 1920-nm diode endolaser.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Endovenous 1920-nm diode laser
Patients with saphenous veins treated with a new 1920-nm diode endolaser.
Endovenous 1470-nm diode laser
Patients with saphenous veins treated with the standard 1470-nm diode endolaser.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Acute or previous thrombophlebitis or deep vein thrombosis.
* Pregnant patient.
18 Years
70 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Instituto Vascular BH
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Daniel Mendes Pinto
Daniel Mendes Pinto, MD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Daniel M Pinto, MD
Role: PRINCIPAL_INVESTIGATOR
Instituto Vascular BH
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Children ABC hospital
Belo Horizonte, Minas Gerais, Brazil
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Rasmussen LH, Lawaetz M, Bjoern L, Vennits B, Blemings A, Eklof B. Randomized clinical trial comparing endovenous laser ablation, radiofrequency ablation, foam sclerotherapy and surgical stripping for great saphenous varicose veins. Br J Surg. 2011 Aug;98(8):1079-87. doi: 10.1002/bjs.7555.
Siribumrungwong B, Noorit P, Wilasrusmee C, Attia J, Thakkinstian A. A systematic review and meta-analysis of randomised controlled trials comparing endovenous ablation and surgical intervention in patients with varicose vein. Eur J Vasc Endovasc Surg. 2012 Aug;44(2):214-23. doi: 10.1016/j.ejvs.2012.05.017. Epub 2012 Jun 15.
Pan Y, Zhao J, Mei J, Shao M, Zhang J. Comparison of endovenous laser ablation and high ligation and stripping for varicose vein treatment: a meta-analysis. Phlebology. 2014 Mar;29(2):109-19. doi: 10.1177/0268355512473911. Epub 2013 May 6.
Vuylsteke ME, Vandekerckhove PJ, De Bo T, Moons P, Mordon S. Use of a new endovenous laser device: results of the 1,500 nm laser. Ann Vasc Surg. 2010 Feb;24(2):205-11. doi: 10.1016/j.avsg.2009.06.024. Epub 2009 Sep 11.
von Hodenberg E, Zerweck C, Knittel M, Zeller T, Schwarz T. Endovenous laser ablation of varicose veins with the 1470 nm diode laser using a radial fiber - 1-year follow-up. Phlebology. 2015 Mar;30(2):86-90. doi: 10.1177/0268355513512825. Epub 2013 Nov 29.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20130220
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.