Production of a Patient-specific Simulator for Endovascular Aneurysm Repair Training
NCT ID: NCT02372214
Last Updated: 2018-05-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
55 participants
INTERVENTIONAL
2014-03-31
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Use of Smart Glasses for Ultrasound Guided Peripheral Venous Access
NCT03565419
Measurement of Hemodynamic Responses to Lower Body Negative Pressure
NCT03582501
Using a Infrared Thermometer to the Early Detection of Catheter Related Infections
NCT02077816
Effects of Different Intra-arterial Catheter Size on Frequency of Optimal Dynamic Response in Radial Arterial Waveform
NCT03642756
Neonatal Umbilical Catheter Pathway Simulator
NCT07142434
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Clinics Hospital of São Paulo University Medical School
Introduction
The aorta aneurysm is a common clinical condition that implies in considerable threatening to the life of patients. Before the year 2000, 99% of the abdominal aortic aneurysm (AAA) repair where performed with open surgery. Nevertheless, Catheter-based minimally invasive interventions are rapidly becoming the preferred initial treatment in patients with vascular disease . After 2004, the endovascular treatment of AAA increased to 52%. This changing venue requires a shift in our approach to training both fellows as well as general surgical residents during their exposure to vascular surgery.
Currently, supervised training with progressive exposure to procedures is the norm. Nevertheless, simulations based training may allow a shortening of the learning curve and avoid the exposure of the patients to unnecessary risks.
Using the rapid prototyping it is possible to build models in flexible materials that are helpful for training surgeons while simulating surgical procedures in a very realistic manner.
The possibility of training surgical procedures in general as well as patient-specific procedures might improve the surgeon's abilities and results . Rapid prototyping models allow for intensive training of young surgeons, e.g., for endovascular stent implantation simulating in vivo conditions and real tissues without any risk of patient complications and with no exposure of the surgeon to radiation or biologic risks.
After being adequately trained on models, surgeons feel more confident while going to the operating room for actual surgery. Besides, the pre-operative simulation of a specific and complex surgery provides a unique opportunity to employ surgical steps in order to determine the best operating strategy.
Simulators for catheter-based intervention have been available for approximately 5 years, and the technology is evolving rapidly. Currently, simulators are expensive and access has been limited. The ultimate test of simulation is to demonstrate that performance improves in the operating room.
To this end, we designed a randomized prospective study to describe the creation of a patient-specific simulator for training in endovascular infra-renal aneurysm correction and we will analyze the effect of simulator training on the performance of vascular surgery residents.
Objectives:
Primary: Production of a patient-specific simulator for training in endovascular infra-renal aneurysm repair.
Secondary: Analyze the effect of simulator training on the performance of vascular surgery residents.
Methods:
Production of a patient-specific simulator: The process chain on the production of a three-dimensional rapid prototype model consists of the following three steps: Image acquisition, Image post-processing and 3D printing. Patients will undergo a angioCT, with slice thickness of 1mm. Acquired data will be saved in the common DICOM format (Digital Imaging and Communications in Medicine). Dedicated high performance workstations equipped with post-processing tools will be used for processing the DICOM images generated during acquisition. The DICOM data will be transformed into a STL (Surface Tesselation Language) file format. The 3D machine reads in data from a CAD drawing and lays down successive layers of liquid, powder, or the sheet material, and in this way builds up the model from a series of cross sections. With that, a patient-specific pulsatile model will be produced.
Analyze the effect of simulator training on the performance of vascular surgery residents: The study will be performed during a period of two years (2014 and 2015), at the Clinics Hospital of São Paulo University Medical School.
All the endovascular aneurysm repair (EVAR) performed in during this time will be analyzed. According to the average number of EVAR in this service, we calculate that this research will include at least 60 patients.
Ten vascular surgery residents coursing the last year of practice will be randomized into the 2 groups (this is the total number of residents in our service).
Inclusion Criteria:
* Patients with infra-renal aneurysm with diameter of 5,5cm or more
* Residents of the last year of vascular surgery at Clinics Hospital of São Paulo University Medical School
Exclusion Criteria:
* Patients not suitable for endovascular aneurysm repair
* Patients with iliac aneurysm that require iliac bifurcated grafts
* Residents who don't want participate
* Group 1 (30 patients/5residents): patients will undergo endovascular aneurysm repair according to the hospital routine. The residents will perform the procedure under supervision of a senior surgeon. It is an observational part of the study, which has already been done during the year 2014.
* Group 2 (30 patients/5residents): patients will have their aneurysm impressed by a 3D printing. The senior vascular surgeon and the residents of this group will be able to practice the procedure in the model as many times as they wish before the surgery. After the training, the EVAR will be performed according to the routine of the hospital.
During the surgery, objective parameters will be analyzed: radioscopy time, volume of contrast injected, total procedure time, number of catheters and guide-wires used, technical success. The patients will be followed until they leave the hospital. Morbidity (myocardial infarction, renal failure, pulmonary complications) and mortality during the peri-operative time (30 days) will be analyzed. The surgeon will answer a questionnaire about the experience. The data from the two groups will be compared.
This study is approved by the national ethics committee.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
HEALTH_SERVICES_RESEARCH
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group 1
30 patients/5 vascular surgery residents The residents of the last year of vascular surgery will perform the procedure under supervision of a senior surgeon
No interventions assigned to this group
Group 2
30 patients/5 vascular surgery residents Patients will have their aneurysm impressed by a 3D printing. The senior vascular surgeon and the residents of this group will be able to practice the procedure in the model as many times as they wish before the surgery. After the training, the EVAR will be performed according to the routine of the hospital.
Training
Patients will have their aneurysm impressed by a 3D printing. The senior vascular surgeon and the residents of this group will be able to practice the procedure in the model as many times as they wish before the surgery. After the training, the EVAR will be performed according to the routine of the hospital.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Training
Patients will have their aneurysm impressed by a 3D printing. The senior vascular surgeon and the residents of this group will be able to practice the procedure in the model as many times as they wish before the surgery. After the training, the EVAR will be performed according to the routine of the hospital.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Residents of the last year of vascular surgery at Clinics Hospital of São Paulo University Medical School
Exclusion Criteria
* Patients with iliac aneurysm that require iliac bifurcated grafts
* Residents who don't want participate
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Sao Paulo General Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Nelson De Luccia, PhD
Role: STUDY_DIRECTOR
Professor of São Paulo University Medical School
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Clinics Hospital of São Paulo University Medical School
São Paulo, São Paulo, Brazil
Countries
Review the countries where the study has at least one active or historical site.