Indication of Permanent Cardiac Parcing After Tanscatheter Aortic Valve Implantation
NCT ID: NCT02337140
Last Updated: 2016-12-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
165 participants
INTERVENTIONAL
2014-08-31
2016-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The primary end-point of this study is to confirm that standard criterion for pacing are reliable in post-TAVI conduction disorders and to analyze the contribution of a systematic electrophysiological study (EPS).
In TAVI patients, indications for pacing were persistent high-degree atrioventricular block (AVB) or bundle branch block appearance associated to HV interval longer than 70ms, 24 hours after the procedure.
After a two-month follow-up, clinical and ECG evaluation and 24-hour holter monitoring will be realized in patients without pacemaker and compared to data obtained from the devices in pacemaker-implanted patients (% of ventricular pacing \> 1% ; presence of more than 1 AVB episod).
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
At the inclusion, clinical baseline and electrocardiographic data will be collected. During the procedure, baseline ECG data as well as conduction disorders will be recorded. An EP study will be performed (measure of AH and HV intervals) before and after TAVI. Aortic surface area, transvalvular mean gradient, presence of periprothetic leak and LV ejection fraction will be determined by echocardiography within the first 24 hours.
After the procedure, a 24-hour ECG monitoring will be done in ICU. A pacemaker will be implanted in case of persistent severe conduction disorders at 24 hours post-TAVI . All patients will be implanted with SORIN Group KORA DR devices to benefit from the AAI-SafeR mode and the AVB episodes automated analysis. All implanted pacemakers will be settled with identical parameters to allow appropriate patient data analysis (AAI-SafeR for sinus rhythm patients and VVIR in chronic atrial fibrillation patients).
In patients with 24-hour persistence of bundle branch block onset after TAVI, a repeated EPS with HV recording will be performed. If HV interval is \> 70ms, a pacemaker will be implanted and the patient will be added to the pacemaker-implanted patients. In the absence of persistent conduction disorder 24h after the procedure, no specific supervision will be done.
All patients will have a 2-month follow up. At this time, clinical, ECG and echocardiographic data will be collected. Additional 24-hour Holter ECG monitoring will be performed in non-implanted patients and additional device control will be performed in implanted patients. Pacemaker implantation will be confirmed if there is more than 1% of ventricular pacing or at least one DDD mode switch.
In non-implanted patients, the non-indication for pacing was confirmed in the absence of clinical event and 24-hour Holter ECG recording abnormality.
The secondary endpoint of the study is to define a posteriori risk factors for pacemaker implantation after TAVI included in the liste hereafter:
* Clinical data: age, drug-induced bradycardia, hypertension, ischemic cardiomyopathy, creatinin clearance, troponin value.
* Electrocardiographic data: QRS duration, PR interval, preexisting bundle branch block or AV block, QRS axis, sinus rhythm
* Echocardiographic data : aortic surface area, LV ejection fraction, aortic annulus/prothesis ratio, aortic annulus/balloon diameter ratio
* Electrophysiological data : HV interval before and after TAVI
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pacemaker
Patient who have been implanted with a pacemaker after TAVI
Pacemaker SORIN Group KORA DR
transcatheter aortic valve implantation (TAVI)
No Pacemaker
Patient who have not been implanted with a pacemaker after TAVI
transcatheter aortic valve implantation (TAVI)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Pacemaker SORIN Group KORA DR
transcatheter aortic valve implantation (TAVI)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* age \> 50 years
* informed and written consent
* patient with social security system
Exclusion Criteria
* patient under guardianship or curatorship
* patient protected by law
50 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital, Montpellier
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
THOMANN SARAH, MD
Role: PRINCIPAL_INVESTIGATOR
University Hospital, Montpellier France
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Arnaud de Villeneuve
Montpellier, , France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
9357
Identifier Type: -
Identifier Source: org_study_id