The Association Between Severity of Hypertensive Disorder During Pregnancy and Endothelial Dysfunction

NCT ID: NCT02334839

Last Updated: 2015-01-08

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

150 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-09-30

Study Completion Date

2015-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Preeclampsia toxemia (PET) is a pregnancy related complication that is usually expressed as new onset hypertension and proteinuria after 20 weeks of gestation. scarce data exists regarding the effectiveness of PAT plethysmography use in women with PET and whether adverse results are found compared to healthy gravidas. Thus, we aimed to assess endothelial function using PAT plethysmography in women with PET and compare their results to both healthy gravidas and those with only gestational hypertension.

.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Preeclampsia toxemia (PET) is a pregnancy related complication that is usually expressed as new onset hypertension and proteinuria after 20 weeks of gestation. Although the exact pathophysiology is unclear, it's related to abnormal placentation and subsequent vascular pathology. Endothelial dysfunction was found to play a significant role in the risk of cardiovascular event in general. Moreover, few studies found a relation between endothelial dysfunction and PET. There are several methods for the assessment of endothelial function, with Peripheral Artery Tone (PAT) plethysmography being an emerging non-invasive promising technique. However, scarce data exists regarding the effectiveness of PAT plethysmography use in women with PET and whether adverse results are found compared to healthy gravidas.

Thus, we aimed to assess endothelial function using PAT plethysmography in women with PET and compare their results to both healthy gravidas and those with only gestational hypertension.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Endothelial Dysfunction

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Preeclampsia

women with diagnosed preeclampsia

Observational only

Intervention Type OTHER

Endothelial function will be assessed using ENDO-PAT (Itamar medical LTD, Caesarea, Israel) device, which evaluates the change in peripheral vascular tone in reaction to temporal ischemia in a process called Reactive Hyperemia (RH) .The RH-PAT is a blood pressure measurement-like cuff which is placed on the non-dominant arm. A pneumatic probe is placed on the index finger bilaterally (one serves as a control). After a baseline assessment for a 5 minutes period, the cuff is inflated to a 60mm Hg pressure above the systolic pressure in order to occlude the arterial flow distal to the brachial artery. After 5 minutes of occlusion, a prompt deflation of the cuff results in a RH response and vasodilatation in the distal arteries including those monitored in the index finger. The sensor translates the change in vascular tone and the ENDO-PAT V3.0.4 device analyzes the data automatically. The results are given in a RH index scale that reflects the level of reactive hyperemia.

gestational hypertension

women with diagnosed gestational hypertension without preeclampsia

Observational only

Intervention Type OTHER

Endothelial function will be assessed using ENDO-PAT (Itamar medical LTD, Caesarea, Israel) device, which evaluates the change in peripheral vascular tone in reaction to temporal ischemia in a process called Reactive Hyperemia (RH) .The RH-PAT is a blood pressure measurement-like cuff which is placed on the non-dominant arm. A pneumatic probe is placed on the index finger bilaterally (one serves as a control). After a baseline assessment for a 5 minutes period, the cuff is inflated to a 60mm Hg pressure above the systolic pressure in order to occlude the arterial flow distal to the brachial artery. After 5 minutes of occlusion, a prompt deflation of the cuff results in a RH response and vasodilatation in the distal arteries including those monitored in the index finger. The sensor translates the change in vascular tone and the ENDO-PAT V3.0.4 device analyzes the data automatically. The results are given in a RH index scale that reflects the level of reactive hyperemia.

healthy

women without gestational hypertension or preeclampsia

Observational only

Intervention Type OTHER

Endothelial function will be assessed using ENDO-PAT (Itamar medical LTD, Caesarea, Israel) device, which evaluates the change in peripheral vascular tone in reaction to temporal ischemia in a process called Reactive Hyperemia (RH) .The RH-PAT is a blood pressure measurement-like cuff which is placed on the non-dominant arm. A pneumatic probe is placed on the index finger bilaterally (one serves as a control). After a baseline assessment for a 5 minutes period, the cuff is inflated to a 60mm Hg pressure above the systolic pressure in order to occlude the arterial flow distal to the brachial artery. After 5 minutes of occlusion, a prompt deflation of the cuff results in a RH response and vasodilatation in the distal arteries including those monitored in the index finger. The sensor translates the change in vascular tone and the ENDO-PAT V3.0.4 device analyzes the data automatically. The results are given in a RH index scale that reflects the level of reactive hyperemia.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Observational only

Endothelial function will be assessed using ENDO-PAT (Itamar medical LTD, Caesarea, Israel) device, which evaluates the change in peripheral vascular tone in reaction to temporal ischemia in a process called Reactive Hyperemia (RH) .The RH-PAT is a blood pressure measurement-like cuff which is placed on the non-dominant arm. A pneumatic probe is placed on the index finger bilaterally (one serves as a control). After a baseline assessment for a 5 minutes period, the cuff is inflated to a 60mm Hg pressure above the systolic pressure in order to occlude the arterial flow distal to the brachial artery. After 5 minutes of occlusion, a prompt deflation of the cuff results in a RH response and vasodilatation in the distal arteries including those monitored in the index finger. The sensor translates the change in vascular tone and the ENDO-PAT V3.0.4 device analyzes the data automatically. The results are given in a RH index scale that reflects the level of reactive hyperemia.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Maternal age 18-40 years old
2. 27 and above weeks of gestation
3. Singleton pregnancy
4. Agreed to participate in the study and signed on informed consent form.

Exclusion Criteria

1. Known ischemic heart disease or angina pectoris
2. Active smoker
3. Dyslipidemia, chronic hypertension. Renal disease, diabetes mellitus (gestational or pregestational)
4. Active treatment with anti-hypertensive medication, anti-aggregation medication or lipid lowering agents.
Minimum Eligible Age

18 Years

Maximum Eligible Age

40 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Rabin Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Liran hiersch

MD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Liran Hiersch

Role: PRINCIPAL_INVESTIGATOR

Rabin Medical Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Rabin medical center

Petah Tikva, , Israel

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Israel

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Liran Hiersch

Role: CONTACT

+972-3-9377490

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Liran Hiersch

Role: primary

+972-9377490

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

0206-14

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.