Automatic Image Analyzer to Assess Retinal Vessel Caliber
NCT ID: NCT02087605
Last Updated: 2016-09-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
400 participants
OBSERVATIONAL
2014-04-30
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods / Design Design : In the first phase , will be a cross- sectional study and a second phase will be a prospective observational study with annual follow-up for 4 years. The study will be conducted in primary care including 386 subjects. Main measurements: blood pressure, carotid intima-media thickness using carotid ultrasound , central blood pressure and wave velocity pulse by SphygmoCor system, Cardio-ankle vascular index (CAVI) by VASERA® VS1500 , evaluation of hypertrophy ventricular using a digital ECG and renal injury . Retinal vascular evaluation will be done by a non-mydriatic TOPCON TRCNW200 getting focused papilla, nasal and temporal and developed by software images automatically calculate the thickness of the retinal vessels , the arteriovenous index, the vascularized area and branching pattern . For validation software retina intra and inter - observer variability , the correlation of the tool measurement with AVindex , and concurrent validity with parameters of vascular structure and function and target organ damage and association analysis will analyze the different parameters of the estimated retina and evolution or appearance of new lesions in the target organs.
Discussion The validation of the tool contribute to the analysis of retinal vessels improved reliability by reducing the intervention of the observer and further validate the use of more information than the previously used , especially surface vascularization and vessel branching patterns .
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optical Coherence Tomography Angiography Examinations in Chronic Retinal Artery Occlusion
NCT03357146
Semi-manual Vessel Density Analysis on Optical Coherence Tomography Angiography Images of Healthy Adults
NCT03590899
10-year Progression of Diabetic Retinopathy: Identification of Signs and Surrogate Outcomes
NCT04650165
REtinaL Imaging & Ambulatory BLood PrEssure
NCT04118205
Retinal Imaging by Adaptive Optics in Healthy Eyes and During Retinal and General Diseases
NCT01546181
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The study population will be subject 30 to 75 years with a cardiovascular risk factor defined by the European Hypertension Guide 2013 and does not meet any of the defined exclusion criteria: patients who can not comply with the requirements of the protocol due to mental and / or cognitive impairment, no partners, educational and understanding limitations and severe comorbidity that would endanger his life in the next 12 months. By consecutive sampling of all patients referred to the research unit for assessment of cardiovascular risk, their participation is requested from those who meet the inclusion criteria and have no reason for exclusion to the size of the estimated sample.
Sample size was estimated to detect a correlation coefficient between velocity and the pulse wave parameters retinal 0.15, alpha risk of 0.05 and a beta risk of 0.20, and an estimated loss by difficulty technical or abandonment of monitoring 10%, so 386 subjects, who will be included in the study required.
Software Validation retina For validation of the retina software Follow these steps after a previous training of evaluators who will make the evaluation of the images . 1 - intra- observer variability . Assessing the repeatability of the measurement, an operator must measure the same picture in the same individual, at least twice. To do this, an operator will evaluate 100 images of a random subsample of 50 patients with a gap of one week between the two embodiments . In this case , the operator and the images analyzed are the same on both days and will not have information on the previous assessment . 2 - inter-observer variability . To assess the reproducibility of the measurement system , a new operator, different from phase 1, evaluated the same 100 images previously analyzed . This operator will ignore the results that have been obtained in the previous phase. The two operators have the same experience in the field and in the use of software , in addition, both receive the same previous training. 3.- And with retina developed software program provides the results on the evaluation of arterial / venous , thickness of the vein and the artery index. To assess the degree of agreement between the two methodologies (AVindex ) valuation of 100 images were made with the two tools . In this way, we can show that the new method and provides the same results improves daily practice having more objective and faster processing of results. 4.- The validity of the measurement was analyzed in the total sample, 386 and 772 subjects fundus , analyzing the relationship of the results to the carotid intima-media thickness as a measure of vascular structure , the speed of the pulse wave as measure of vascular function and arterial stiffness gold standard (arterial stiffness ) in Cardio Ankle vascular Index , renal function , and electrocardiographic parameters estimated with the Framingham cardiovascular risk. 5.- also the association of the different parameters of the estimated retina and evolution or appearance of new lesions in target organs and cardiovascular monitoring of patients during the four years of the second phase of this project will be analyzed events
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
30 Years
75 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Salamanca
OTHER
Fundacion para la Investigacion y Formacion en Ciencias de la Salud
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Juan M Corchado, PhD
Role: STUDY_DIRECTOR
University of Salamanca
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Primary care research unit La Alamedilla
Salamanca, Salamanca, Spain
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Garcia-Ortiz L, Recio-Rodriguez JI, Parra-Sanchez J, Gonzalez Elena LJ, Patino-Alonso MC, Agudo-Conde C, Rodriguez-Sanchez E, Gomez-Marcos MA; Vaso-risk group. A new tool to assess retinal vessel caliber. Reliability and validity of measures and their relationship with cardiovascular risk. J Hypertens. 2012 Apr;30(4):770-7. doi: 10.1097/HJH.0b013e3283506628.
Garcia-Ortiz L, Gomez-Marcos MA, Recio-Rodriguez JI, Maderuelo-Fernandez JA, Chamoso-Santos P, Rodriguez-Gonzalez S, de Paz-Santana JF, Merchan-Cifuentes MA, Corchado-Rodriguez JM; ALTAIR group. Validation of the automatic image analyser to assess retinal vessel calibre (ALTAIR): a prospective study protocol. BMJ Open. 2014 Dec 2;4(12):e006144. doi: 10.1136/bmjopen-2014-006144.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
C2013
Identifier Type: -
Identifier Source: org_study_id
More Related Trials