Early Investigation of High Precision Radiotherapy Prior to Commencing Standard Radiotherapy for Prostate Cancer
NCT ID: NCT02004223
Last Updated: 2021-06-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
42 participants
INTERVENTIONAL
2014-01-31
2018-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Hypothesis: It is safe to give patients an extra two doses of high-precision radiotherapy prior to commencing a shorter period of standard radiotherapy for prostate cancer.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Phase I-II Dose Escalation Study of Stereotactic Body Radiation Therapy in Patients With Localized Prostate Cancer
NCT02254746
Two StereoTactic Ablative Adaptive Radiotherapy Treatments for Localized Prostate Cancer
NCT02031328
Proton Radiotherapy for Patients With Non-Small Cell Lung Cancer (NSCLC)
NCT00495040
Single Fraction Stereotactic Body Radiation Therapy After Surgery in Treating Patients With Non-small Cell Lung Cancer
NCT04073745
Using Breath, Cell Free DNA and Image Analysis to PRedIct Normal TissUe and Tumour Response During Prostate Cancer SBRT
NCT04081428
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Prostate cancer has a slow growth with a potential doubling time ranging from weeks to months (median 42 days) which has led to the hypothesis that prostate cancer will behave more like a late reacting tissue(1). Brenner et al. (2) used data from prostate Low Dose Rate (LDR) permanent seed implants and EBRT series to derive an alpha/beta of approximately 1.5. Many groups have also calculated the alpha/beta ratio to be in the \< 3.0 range(3).
If the alpha/beta ratio for prostate cancer is lower than the surrounding normal tissues (Brenner et al. have estimated the alpha/beta for the rectum to be over 5.0), doses greater than 2 Gy (hypofractionation) will afford an advantage as there will be a greater sensitivity of prostate cancer to radiation, as compared to the bladder or rectum. This benefit has been exploited for many years with High Dose Rate (HDR) brachytherapy using Iridium -192. Typical doses for HDR are 19Gy in two fractions in addition to 46Gy in 23 fractions of EBRT (4). With reference to our own institutional data from HDR brachytherapy we calculated the dose distribution in recently treated patients. Due to the nature of the iridium dose distribution, there are considerable areas of much higher dose delivered; 200% of the dose (38Gy) to 12.7% of the target volume, 150% (13.75Gy) to 32.6% of the target volume and 125% (11.9Gy) to 60.1% of the target. Despite the high doses to the periphery of the prostate it is possible to limit the dose to the rectum and bladder to 1cc \< 75% (14.25Gy) and the 1cc urethra to \<125% (23.75Gy) (4). HDR brachytherapy series have reported durable long term Biochemical Failure Free Survival (BFFS), which are as good or better than comparable external beam or surgical series(5). However despite the low toxicity and excellent biochemical outcomes, HDR brachytherapy utilization in Australia is low, with under 300 cases in total per year. This is due to the logistical difficulty of HDR brachytherapy, anaesthetic requirements, nursing care and patient discomfort.
There have been five published studies investigating stereotactic boost in addition to standard fractionation EBRT without using brachytherapy, four reports with the Cyberknife platform (6-9) and one with Intensity Modulated Radiotherapy (IMRT) (10). All of these series have early follow up (FU) with reported BFFS between 77% and 100%. The largest experience is from Katz et al. (8) who reported 73 patients with both intermediate (n= 41) and high risk (n=32) disease. They treated patients with the Cyberknife platform to deliver between 18 and 21 Gy in three fractions in addition to 45 Gy in 25 fractions EBRT. With a median follow up of 33 months, BFFS was 89.5% and 77.7% for the intermediate and high risk patients respectively. A 5 mm expansion from the prostate to the Planned Treatment Volume (PTV) was used except posteriorly, where the margin was 3mm. There was 7% Grade 2 acute genitourinary (GU) and gastrointestinal (GI) toxicity, with late Grade 2 estimates at three years of 5.5% (GU) and 8.2% (GI). Three other series using Cyberknife to mimic HDR were reported between 2008 and 2012 (6, 7, 9). These studies used margins of 0-2 mm posteriorly and 3-5 mm in other directions and reported low rates of Grade 2 and Grade 3 toxicity. Two of these reports specifically attempted to reproduce the heterogeneity of HDR with large areas of the PTV receiving \>125% (40% to 45%) and \>150% (5% to 10%) of the prescribed dose. Miralbell et al. (10) reported a Linac based IMRT boost in 50 patients in 2010. This series used an endorectal balloon but no image guidance, which may be the cause of their unacceptably high five year estimates of late GI Grade 2 toxicity of 26%.
Primary objective:
The primary study goal is to assess the acute toxicity of Stereotactic Body Radiotherapy (SBRT) boost with three increasing dose levels.
Secondary objectives:
* Nadir PSA at three months and over duration of follow-up
* Three year and five year Freedom From Biochemical Failure (FFBF) (Nadir + 2.0)
* Planning feasibility (Minor and Major planning violations)
* Late Gastrointestinal and Genitourinary Toxicity (modified Radiation Therapy Oncology Group (RTOG) scale)
* Patient reported QOL (EPIC-SF-12)
Hypothesis: It is safe to dose escalate prostate cancer treatment with a stereotactic boost of up to 30Gy in two fractions to the dominant nodule combined with external beam radiotherapy of 46Gy in 23 fractions with \< 15% Grade 2 acute morbidity and \< 5% Grade 3 acute morbidity.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Dose escalation using stereotactic boost
Dose level allocation - Participants will be allocated to the current dose level, or if the current dose level has been filled and acceptable toxicity has been established, they will be enrolled into the next dose level
Dose escalation using stereotactic boost
This is a dose escalation study. Participants will be allocated to the current dose level, or if the current dose level has been filled and acceptable toxicity has been established, they will be enrolled into the next dose level.
The first dose level will be 20Gy in 2 fractions to PTV and 25Gy to Gross Target Volume (GTV) if identified. The second dose level will be 22Gy in 2 fractions to PTV and 27.5Gy to GTV if identified. The dose level will be 24 Gy in 2 fractions to PTV and 30Gy to GTV if identified.
Following stereotactic boost, all participants will receive 46Gy in 23 fractions radiotherapy to the prostate / seminal vesicles +/- lymph nodes.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Dose escalation using stereotactic boost
This is a dose escalation study. Participants will be allocated to the current dose level, or if the current dose level has been filled and acceptable toxicity has been established, they will be enrolled into the next dose level.
The first dose level will be 20Gy in 2 fractions to PTV and 25Gy to Gross Target Volume (GTV) if identified. The second dose level will be 22Gy in 2 fractions to PTV and 27.5Gy to GTV if identified. The dose level will be 24 Gy in 2 fractions to PTV and 30Gy to GTV if identified.
Following stereotactic boost, all participants will receive 46Gy in 23 fractions radiotherapy to the prostate / seminal vesicles +/- lymph nodes.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* PSA obtained within three months prior to enrollment.
* International Prostate Symptom Score (I-PSS) score \<15
* No contraindication to MRI (pacemaker, severe claustrophobia)
* Patient must be able to have fiducial markers placed in the prostate (if on anticoagulants, must be cleared by LMO or cardiologist).
* ECOG performance status 0-2
* Ability to understand and the willingness to sign a written informed consent document.
Exclusion Criteria
* Prior total prostatectomy
* Unwilling or unable to give informed consent
* Unwilling or unable to complete quality of life questionnaires.
35 Years
85 Years
MALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Royal North Shore Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Professor Thomas Eade
Senior Staff Specialist (Radiation Oncology)
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thomas N Eade, MBBS
Role: PRINCIPAL_INVESTIGATOR
Royal North Shore Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Northern Sydney Cancer Centre, Royal North Shore Hospital
St Leonards, New South Wales, Australia
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13-NSCCRO-P001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.