Effects of a rapamycIn-eluting carboNized Stent With a Completely biodEgradable polymeR Coating
NCT ID: NCT01981304
Last Updated: 2013-11-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
50 participants
OBSERVATIONAL
2014-01-31
2016-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Drugs, platforms and polymers are considered the protagonists of these pathophysiologic processes.
The objectives of the INERT study is to assess the extent of inflammation and endothelial damage induced by the first carbonized bio-absorbable coated rapamycin-eluting coronary stent at time of percutaneous coronary intervention and correlate the extent of these abnormalities with short and long-term clinical outcome and post-procedural evaluation of success.
As part of the study, a randomized sub-study will be carried out at the Coordinating Center in order to compare the biohumoral, clinical and procedural findings between patients with the carbonized bio-absorbable coated rapamycin-eluting coronary stent and those randomly assigned to receive stents with different platforms and polymers.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Drugs, platforms and polymers are considered the protagonists of these pathophysiologic processes.
Platforms Due to advances in stent technology, several stent platforms are now available, including the stainless steel, the cobalt-chromium, and the platinum-chromium stent series. Pre-clinical animal studies suggest that some platforms might have important advantages in terms of vascular compatibility and early and late healing. In a rabbit denudation model, it was shown that at 14 days the luminal surface area is incompletely endothelialised with the CrCo stents but nearly complete for other metals. Additionally, it has been shown that a thinner-strut stent is associated with reduced fibrin deposition and more rapid fibrin clearance in porcine coronary arteries compared with thicker stents, thus suggesting that the thin stent platforms may induce less injury. As a matter of fact, The second-generation DESs, with thinner struts, are obviously associated with a suppression of the neointimal response and a more rapid re-endothelialization but stainless steel based stent design might have a better conformability to the vessel wall which results to less malposition.
Polymers The polymer coating that elutes the antiproliferative drug has been linked to complications including delayed vessel healing, hypersensitivity reactions, atheroma, and restenosis, with the potential for repeat intervention, stent thrombosis, acute myocardial infarction, and sudden death.
The link between the permanent polymer and late adverse events has prompted the development of a variety of biodegradable polymer coatings. Absorption of the polymer may lower the rates of stent thrombosis, particularly beyond 1 year after stent implantation. In addition, stents with absorbable polymers may allow a shorter duration of dual antiplatelet therapy (DAPT) than currently recommended The incidence of late adverse events is likely to be lower after the absorption of the polymer than after the implantation of drug-eluting stents coated with a permanent polymer, as there is less ongoing inflammation than with permanent polymers. In a meta-analysis of randomized trials, metal stents that release an antiproliferative drug from an absorbable polymer coating had lower rates of MACE out to 4 years than metal stents that released a drug from a durable polymer. The randomized LEADERS (Limus Eluted from A Durable versus ERodable Stent) trial studies showed that a biolimus eluting stent coated with a biodegradable polymer had a lower risk of adverse cardiac events associated with very late ST through 5 years of follow-up, improving the long-term clinical outcomes compared with sirolimus-eluting stents coated with a durable polymer
Bio-absorbable coated Rapamycin-Eluting Coronary Carbonized Stent The new Rapamycin-Eluting Coronary Stent System is the first carbonized stent with a completely biodegradable polymer coating which contains rapamycin as drug for preventing early thrombotic and re-stenotic events. Absorption of carrier coating and drug takes place simultaneously within 6 weeks after implantation, leaving a carbonized stent platform behind. Because of the biodegradable polymer based technology, duration of the dual antiplatelet therapy after DES implantation might be shortened up to a few months.
The stent platform is a stainless stent that received CE-mark in 2001. It is a laser cut slotted tube, with multi-cellular design. The stent is characterized by a carbon-ion implanted layer (Inert Carbon Technology) that becomes incorporated within the metal lattice down to 0.05 mcm and avoids the leakage of heavy-metal ions as nickel and molybdenum. Usually, heavy metal ions released from stainless steel stent can cause allergic and inflammatory reactions which might be associated with in-stent restenosis. Conversely, the INERT-Technology alters common 316 stainless steel into a highly biocompatible alloy biodegradable polymer based sirolimus-eluting stent which is associated with earlier neointimal healing as compared to permanent polymer based eluting stent.
After carbonizing, the stent is coated with a thin layer of biodegradable polymer (PLGA). The coating is cleared from the stent in 45 to 60 days and and its degradation products (lactic and glycolic acid) are completely absorbed into the tissue within 90 days, leaving an inert bare metal stent, as confirmed during preclinical animal testing . This approach of drug delivery to the artery is aimed at achieving tissue coverage of the stent struts without excessive neointimal proliferation. Pre-clinical 'in vivo' studies have shown that the new Rapamycin-Eluting Coronary Stent System inhibit struts-associated inflammation and neointimal formation in the porcine coronary model.
Purpose
The objectives of the INERT study is to assess the extent of inflammation and endothelial damage induced by the first carbonized bio-absorbable coated rapamycin-eluting coronary stent at time of percutaneous coronary intervention and correlate the extent of these abnormalities with short and long-term clinical outcome and post-procedural evaluation of success.
As part of the study, a randomized sub-study will be carried out at the Coordinating Center in order to compare the biohumoral, clinical and procedural findings between patients with the carbonized bio-absorbable coated rapamycin-eluting coronary stent and those randomly assigned to receive stents with different platforms and polymers.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
DES with a biodegradable polymer coating
Patients receiving the first carbonized bio-absorbable coated rapamycin-eluting coronary stent at time of percutaneous coronary intervention
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Roma La Sapienza
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Francesco Pelliccia
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Cesare Greco, MD
Role: STUDY_CHAIR
University Sapienza
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
807/2013/D
Identifier Type: -
Identifier Source: org_study_id