Calibration and Evaluation of an Audio Pulse Oximeter Sensor (AudioOx) at Ascent and Descent From Simulated Altitude
NCT ID: NCT01732029
Last Updated: 2017-06-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2013-01-31
2013-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Camera Oximeter: A Calibration Study
NCT01732016
Comparison of Pulse Oximetry (SpO2) With Different Oximeters and Arterial Saturation (SaO2): Oxygap2 Study
NCT06102499
Pulse Oximeter Accuracy in Healthy Humans During Hypoxia
NCT06142019
Accuracy of Pulse Oximeters With Profound Hypoxia at Rest
NCT04814823
Determination of SpO2 and PR Accuracy Specifications at Rest (71Ag_Vital-0031)
NCT05297500
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
We at the Electrical and Computer Engineering in Medicine Group (ECEM) at the University of British Columbia, Vancouver, Canada, plan to make pulse oximetry available to resource poor countries by designing a low-cost, battery-powered pulse oximeter device consisting of a low-cost pulse oximeter sensor connected to a cell phone. The use of cell phones as patient monitors is appealing as they are widely available in many developing countries. Utilizing battery power, cell phones do not rely on a continuous source of electricity. This is essential, as most low-resource settings lack adequate infrastructure and thus cannot provide the uninterrupted power supply required for conventional patient monitoring. Furthermore, a cell phone has the efficiency, integrated display, and processing power required to analyze and store the raw data derived from the pulse oximeter sensors. Data from the pulse oximeter can be transmitted to referral centers for diagnostic and advisory purposes where cellular and networking services permit.
Proprietary oximeter sensors and modules are expensive. To reduce cost, we are proposing to develop a simple audio pulse oximeter sensor (AudioOx) that that does not require a sensor module and interfaces via the audio jack of any standard cell phone. By utilizing the audio jack for transmission of data from the sensor to phone, we can ensure that cell phone types most common in various areas of the world are universally supported. Preliminary laboratory tests showed that oximetry data from the AudioOx has sufficient signal strength and resolution for extraction of heart rate and SpO2.
Hypothesis:
We hypothesize that this study will allow us to successfully calibrate the AudioOx.
Justification:
Development of pulse oximeters requires calibration and evaluation for accuracy. There is no acceptable surrogate calibration tool for pulse oximeters. To quote the current International Organization for Standardization (ISO) Pulse Oximetry standard document: "There is today no accepted method of verifying the correct calibration of a pulse oximeter probe/pulse oximeter monitor combination other than testing on human beings. This is due to the complexity of the optical intricacies of the interaction of light and human tissue upon which pulse oximetry depends".
A previous calibration study was performed on volunteers during a concurrent study in the UBC hypoxia chamber. The results demonstrated that the AudioOx can be calibrated to within the 4% accuracy required by ISO. The study setup, however, was suboptimal as the measured SpO2 data was predominantly hypoxic. Motion artifacts were also abundant, as the subjects had unrestricted movement.
Objectives:
Our main objective is to improve the calibration of the AudioOx by:
* Asking subjects to remain relatively immobile during data measurement.
* Exposing subjects to a very gradual change in oxygen concentration so that measurements are distributed over the entire clinical range of SpO2 (70% to 100%).
* Using two (instead of one) clinically-approved pulse oximeters from different manufacturers as secondary reference standards.
Our secondary objective is to evaluate and compare the performance of the AudioOx during motion, low perfusion, and rapidly changing SpO2 by:
* Asking the subjects to perform standardized hand and finger motions during data measurement.
* Simulating low perfusion via two methods: by partially occluding the brachial artery using a blood pressure cuff and by having the patient raise their arm for two minutes and using light filters to reduce the red and infra-red signals detected by the pulse oximeter sensors.
* Measuring SpO2 as the subject enters and exits the hypoxia chamber.
Research Method:
This will be a non-invasive concurrent observational study of healthy voluntary adult subjects in a normobaric (sea-level atmospheric pressure) hypoxia (low oxygen) chamber.
Study subjects will be put into a hypoxic state by exposing them to normobaric hypoxia by administrating an air mix containing a reduced O2 concentration. This is achieved in a hypoxia chamber where O2 concentration is gradually reduced to simulate high altitude (about 4500 m).
The goals of the current study are very similar to another study conducted in the hypoxia chamber (REB ID#H12-02362, The Camera Oximeter), the same methodology is applied. This will allow recruiting subjects for both studies and will reduce the total number of subjects necessary for achieving our goal.
Statistical Analysis:
Calibration of SpO2 Data from the initial set of subjects (at least 10) in the study will be used to calibrate the AudioOx oximetry data. Firstly, ratio R is calculated from the red and infra-red (IR) photo-absorbance signals, where
R = ( ACRED / DCRED ) / ( ACIR / DCIR )
ACRED and ACIR are pulsatile components of the red and infra-red light detected by the oximeter photosensor. DCRED and DCIR are constant components of the red and infra-red light detected by the oximeter photosensor.
R values are paired to the reference SpO2 values (average of the two readings from the two reference pulse oximeters) and plotted on a scatter plot. Depending on the shape of the plot, the R values are translated to SpO2 values using a linear equation, multiple linear equations, or polynomial equations.
Evaluation of Accuracy
Readings from the oximeter sensors are grouped into six ranges (70-75%, 76-80%, 81-85%, 86-90%, 91-95% and 96-100%). For each range of SpO2 and the overall range (70-100%) accuracy will be calculated as per ISO definitions:
Accuracy of the pulse oximeter shall be stated in terms of the root-mean-square (rms) difference between AudioOx values (SpO2i) and reference values (SRi), as given by:
Arms = √((∑i=1 to n(SpO2i- SRi)\^2 )/n)
To express Accuracy relative to the "gold-standard" blood gas analysis, the error of the secondary standard pulse oximeter (errorref) will be included:
Accuracy = √(Arms\^2 + error(ref)\^2)
Motion \& low perfusion will be quantified by the proportion of time that the test measurements either gave no readings or were more than 4% different from the corresponding control measurements.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Normobaric hypoxia chamber
Study subjects will be put into a hypoxic state by exposing them to normobaric hypoxia by administrating an air mix containing a reduced O2 concentration. This is achieved in a hypoxia chamber where O2 concentration is gradually reduced to simulate high altitude (about 4500 m).
Normobaric hypoxia chamber
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Normobaric hypoxia chamber
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* UBC students age 18 and older or non-university students age 19 and older
* No medical history of respiratory, cardiovascular and neurological problems (capable of undergoing controlled hypoxemia down to SpO2 of 70%).
Exclusion Criteria
* Smokers or individuals exposed to high levels of carbon monoxide that result in elevated carboxyhemoglobin levels (interferes with oximetry readings)
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of British Columbia
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Mark Ansermino
Principle Investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
BC Children's Hospital
Vancouver, British Columbia, Canada
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Related Info
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
H12-02365
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.