Safety and Performance of TAVI of Venus MedTech Aortic Valve Prosthesis
NCT ID: NCT01683474
Last Updated: 2015-01-06
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
80 participants
INTERVENTIONAL
2012-09-30
2016-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
* Evaluate the performance of Venus MedTech aortic valve prosthesis intervention by femoral artery
* Evaluate safety and clinical benefit of percutaneous implantation of the Venue MedTech aortic valve prosthesis.
* Continuous observe 12 months of safety and efficacy.
2. Approximately 80 patients presenting with native aortic valve stenosis necessitating valve replacement which are considered unsuitable for Surgical Valve Replacement, with a high surgical risk, as attested to by both the surgeon and the cardiologist are recruited in the study.
3. Safety and performance will be evaluated at discharge and at 30 days post procedure. Valve safety, performance and placement will be followed up at 6 and 12 months post-procedure.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Implantation of the Venus P-Valve™ in the Pulmonic Position in Patients With Native Outflow Tracts
NCT02846753
Efficacy and Safety of Venus P-valve to Treat RVOT Stenosis With Pulmonary Regurgitation
NCT02071654
Observational Study of Venus P-Valve
NCT05835349
Multi-center Trial of Percutaneous Pulmonary Valve Implantation With Venus-p
NCT02590679
Transapical Implantation of Ventor Embracer™ Valve in Patients With Severe Aortic Valve Disease
NCT00677638
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Venus A-Valve
single arm with intervention that percutaneous implantation of the Venus MedTech Aortic Valve Prosthesis
Venus MedTech Aortic Valve Prosthesis
Percutaneous implantation of aortic valve of Venus-A
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Venus MedTech Aortic Valve Prosthesis
Percutaneous implantation of aortic valve of Venus-A
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Symptomatic due to aortic valve stenosis as demonstrated by NYHA Functional Class ≥ II
* The subject or the subject's legal representative was informed of the nature of the study, agreed to its provisions and provided written informed consent as approved by the Institutional Review Board of the respective clinical site.
* The subject agreed to comply follow-up evaluation
* is evaluated by at least one cardiologist and two cardiovascular surgeon, and they agreed that medical factors precluding operation suitable for surgery (the probability of death or serious, irreversible morbidity exceeded 50%)
* STS score ≥ 10%
Exclusion Criteria
* Evidence of an acute myocardial infarction ≤ 1 month before the intended treatment \[defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)\].
* Aortic valve is a congenital unicuspid or congenital bicuspid valve, or is non-calcified.
* Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation \>3+).
* Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days (6 month if DES implant)
* Implanted any heart valve prosthesis, prosthetic valve ring, severe mitral valve ring calcification (MAC), severe(\>3+)mitral valve insufficiency, or Gorelin symptom
* Blood dyscrasia such as leukopenia (WBC \< 3×109/L), acute anemia (Hgb \< 90 g/L), thrombocytopenia (PLT \< 50×109/L), bleeding diathesis, or history of coagulopathy.
* Untreated clinically significant coronary artery disease requiring revascularization
* Hemodynamic instability requiring inotropic therapy or mechanical hemodynamic support devices
* Need for emergency surgery for any reason
* Hypertrophic cardiomyopathy with or without obstruction (HOCM)
* Severe ventricular dysfunction with LVEF \< 20%
* Echocardiographic evidence of intracardiac mass, thrombus or vegetation
* Active peptic ulcer or upper gastro-intestinal bleeding within the prior 3 months
* A known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated.
* Native aortic annulus size \< 20 mm or\> 29 mm as measured by echocardiogram.
* Cerebrovascular Accident (CVA) within 6 months, including TIA.
* Renal insufficiency (creatinine \> 3.0 mg/dL) and/or end stage renal disease requiring chronic dialysis.
* Life expectancy \< 12 months
* Significant abdominal or thoracic aorta disease, including aneurysm (defined as maximal luminal diameter 5cm or greater), marked tortuosity (hyperacute bend), aortic arch atheroma (especially if thick \[\> 5 mm\], protruding or ulcerated), narrowing of the abdominal aorta (especially with calcification and surface irregularities), or severe "unfolding" and tortuosity of the thoracic aorta
* Iliofemoral vessel characteristics that would preclude safe placement of 16F or 18F introducer sheath such as severe obstructive calcification, severe tortuosity or vessel size diameter \< 7 mm.
* Currently participating in an investigational drug or another device study.
* Active bacterial endocarditis or other active infections.
* Bulky calcified aortic valve leaflets in close proximity to coronary ostia
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Venus MedTech (HangZhou) Inc.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ruilin Gao, MD
Role: PRINCIPAL_INVESTIGATOR
Chinese Academy of Medical Sciences, Fuwai Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Fu Wai Hospital, CAMS & PUMA
Beijing, Beijing Municipality, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Lei WH, Liao YB, Wang ZJ, Ou YW, Tsauo JY, Li YJ, Xiong TY, Zhao ZG, Wei X, Meng W, Feng Y, Chen M. Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve. J Interv Cardiol. 2019 Nov 3;2019:7348964. doi: 10.1155/2019/7348964. eCollection 2019.
Liao YB, Li YJ, Xiong TY, Ou YW, Lv WY, He JL, Li YM, Zhao ZG, Wei X, Xu YN, Feng Y, Chen M. Comparison of procedural, clinical and valve performance results of transcatheter aortic valve replacement in patients with bicuspid versus tricuspid aortic stenosis. Int J Cardiol. 2018 Mar 1;254:69-74. doi: 10.1016/j.ijcard.2017.12.013. Epub 2017 Dec 9.
Jilaihawi H, Wu Y, Yang Y, Xu L, Chen M, Wang J, Kong X, Zhang R, Wang M, Lv B, Wang W, Xu B, Makkar RR, Sievert H, Gao R. Morphological characteristics of severe aortic stenosis in China: imaging corelab observations from the first Chinese transcatheter aortic valve trial. Catheter Cardiovasc Interv. 2015 Mar;85 Suppl 1:752-61. doi: 10.1002/ccd.25863. Epub 2015 Feb 19.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Venus-A Study
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.