Safety and Performance of TAVI of Venus MedTech Aortic Valve Prosthesis

NCT ID: NCT01683474

Last Updated: 2015-01-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

80 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-09-30

Study Completion Date

2016-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

1. objectives

* Evaluate the performance of Venus MedTech aortic valve prosthesis intervention by femoral artery
* Evaluate safety and clinical benefit of percutaneous implantation of the Venue MedTech aortic valve prosthesis.
* Continuous observe 12 months of safety and efficacy.
2. Approximately 80 patients presenting with native aortic valve stenosis necessitating valve replacement which are considered unsuitable for Surgical Valve Replacement, with a high surgical risk, as attested to by both the surgeon and the cardiologist are recruited in the study.
3. Safety and performance will be evaluated at discharge and at 30 days post procedure. Valve safety, performance and placement will be followed up at 6 and 12 months post-procedure.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

A prospective OPC study to evaluate its performance and long-term safety and effectiveness of Venus-A aortic valve.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Valve Stenosis Aortic Valve Calcification

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Venus A-Valve

single arm with intervention that percutaneous implantation of the Venus MedTech Aortic Valve Prosthesis

Group Type EXPERIMENTAL

Venus MedTech Aortic Valve Prosthesis

Intervention Type DEVICE

Percutaneous implantation of aortic valve of Venus-A

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Venus MedTech Aortic Valve Prosthesis

Percutaneous implantation of aortic valve of Venus-A

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Venus A-Valve Venus A-Valve System

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Senile degenerative aortic valve stenosis with echocardiography derived criteria: mean gradient ≥ 40 mm Hg, or jet velocity ≥ 4.0 m/s, or an aortic valve area (AVA) of \< 0.8 cm2 (or AVA index \< 0.5 cm2/m2)
* Symptomatic due to aortic valve stenosis as demonstrated by NYHA Functional Class ≥ II
* The subject or the subject's legal representative was informed of the nature of the study, agreed to its provisions and provided written informed consent as approved by the Institutional Review Board of the respective clinical site.
* The subject agreed to comply follow-up evaluation
* is evaluated by at least one cardiologist and two cardiovascular surgeon, and they agreed that medical factors precluding operation suitable for surgery (the probability of death or serious, irreversible morbidity exceeded 50%)
* STS score ≥ 10%

Exclusion Criteria

* Patient refuses aortic valve replacement surgery.
* Evidence of an acute myocardial infarction ≤ 1 month before the intended treatment \[defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)\].
* Aortic valve is a congenital unicuspid or congenital bicuspid valve, or is non-calcified.
* Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation \>3+).
* Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days (6 month if DES implant)
* Implanted any heart valve prosthesis, prosthetic valve ring, severe mitral valve ring calcification (MAC), severe(\>3+)mitral valve insufficiency, or Gorelin symptom
* Blood dyscrasia such as leukopenia (WBC \< 3×109/L), acute anemia (Hgb \< 90 g/L), thrombocytopenia (PLT \< 50×109/L), bleeding diathesis, or history of coagulopathy.
* Untreated clinically significant coronary artery disease requiring revascularization
* Hemodynamic instability requiring inotropic therapy or mechanical hemodynamic support devices
* Need for emergency surgery for any reason
* Hypertrophic cardiomyopathy with or without obstruction (HOCM)
* Severe ventricular dysfunction with LVEF \< 20%
* Echocardiographic evidence of intracardiac mass, thrombus or vegetation
* Active peptic ulcer or upper gastro-intestinal bleeding within the prior 3 months
* A known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated.
* Native aortic annulus size \< 20 mm or\> 29 mm as measured by echocardiogram.
* Cerebrovascular Accident (CVA) within 6 months, including TIA.
* Renal insufficiency (creatinine \> 3.0 mg/dL) and/or end stage renal disease requiring chronic dialysis.
* Life expectancy \< 12 months
* Significant abdominal or thoracic aorta disease, including aneurysm (defined as maximal luminal diameter 5cm or greater), marked tortuosity (hyperacute bend), aortic arch atheroma (especially if thick \[\> 5 mm\], protruding or ulcerated), narrowing of the abdominal aorta (especially with calcification and surface irregularities), or severe "unfolding" and tortuosity of the thoracic aorta
* Iliofemoral vessel characteristics that would preclude safe placement of 16F or 18F introducer sheath such as severe obstructive calcification, severe tortuosity or vessel size diameter \< 7 mm.
* Currently participating in an investigational drug or another device study.
* Active bacterial endocarditis or other active infections.
* Bulky calcified aortic valve leaflets in close proximity to coronary ostia
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Venus MedTech (HangZhou) Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ruilin Gao, MD

Role: PRINCIPAL_INVESTIGATOR

Chinese Academy of Medical Sciences, Fuwai Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Fu Wai Hospital, CAMS & PUMA

Beijing, Beijing Municipality, China

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

China

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Runlin Gao, MD

Role: CONTACT

88398866 ext. 8266

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Runlin Gao, MD

Role: primary

References

Explore related publications, articles, or registry entries linked to this study.

Lei WH, Liao YB, Wang ZJ, Ou YW, Tsauo JY, Li YJ, Xiong TY, Zhao ZG, Wei X, Meng W, Feng Y, Chen M. Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve. J Interv Cardiol. 2019 Nov 3;2019:7348964. doi: 10.1155/2019/7348964. eCollection 2019.

Reference Type DERIVED
PMID: 31777470 (View on PubMed)

Liao YB, Li YJ, Xiong TY, Ou YW, Lv WY, He JL, Li YM, Zhao ZG, Wei X, Xu YN, Feng Y, Chen M. Comparison of procedural, clinical and valve performance results of transcatheter aortic valve replacement in patients with bicuspid versus tricuspid aortic stenosis. Int J Cardiol. 2018 Mar 1;254:69-74. doi: 10.1016/j.ijcard.2017.12.013. Epub 2017 Dec 9.

Reference Type DERIVED
PMID: 29246428 (View on PubMed)

Jilaihawi H, Wu Y, Yang Y, Xu L, Chen M, Wang J, Kong X, Zhang R, Wang M, Lv B, Wang W, Xu B, Makkar RR, Sievert H, Gao R. Morphological characteristics of severe aortic stenosis in China: imaging corelab observations from the first Chinese transcatheter aortic valve trial. Catheter Cardiovasc Interv. 2015 Mar;85 Suppl 1:752-61. doi: 10.1002/ccd.25863. Epub 2015 Feb 19.

Reference Type DERIVED
PMID: 25630494 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Venus-A Study

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Venus-Vitae Pivotal Study Smart-Align Study
NCT05991271 NOT_YET_RECRUITING NA
Multi-center Trial of ValveClamp