Trial Outcomes & Findings for Neuromonitoring During the Latarjet Procedure (NCT NCT01621126)

NCT ID: NCT01621126

Last Updated: 2016-05-23

Results Overview

Nerve palsy of any nerve(s) in the operative upper extremity.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

40 participants

Primary outcome timeframe

up to 24 weeks after the procedure

Results posted on

2016-05-23

Participant Flow

Participant milestones

Participant milestones
Measure
Intra-op Neuromonitoring
Intra-operative neuromonitoring (XLTEK/NATUS EP Protektor): Device: Intra-operative neuromonitoring A XLTEK/NATUS EP Protektor machine (at MGH) or a Cadwell Cascade Elite neuromonitoring machine (at BWH), both FDA approved for intra-operative neuromonitoring, will deliver the electrical stimulus applied transcranially to stimulate the motor cortex, while motor evoked responses will be recorded from different myotomes from both upper limbs. Also the same equipment will deliver electrical stimulus to stimulate peripherally the median and ulnar nerves at the wrists, with recording of the thalamocortical potentials in the scalp channels.
Overall Study
STARTED
40
Overall Study
COMPLETED
34
Overall Study
NOT COMPLETED
6

Reasons for withdrawal

Reasons for withdrawal
Measure
Intra-op Neuromonitoring
Intra-operative neuromonitoring (XLTEK/NATUS EP Protektor): Device: Intra-operative neuromonitoring A XLTEK/NATUS EP Protektor machine (at MGH) or a Cadwell Cascade Elite neuromonitoring machine (at BWH), both FDA approved for intra-operative neuromonitoring, will deliver the electrical stimulus applied transcranially to stimulate the motor cortex, while motor evoked responses will be recorded from different myotomes from both upper limbs. Also the same equipment will deliver electrical stimulus to stimulate peripherally the median and ulnar nerves at the wrists, with recording of the thalamocortical potentials in the scalp channels.
Overall Study
Physician Decision
6

Baseline Characteristics

Neuromonitoring During the Latarjet Procedure

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Intra-op Neuromonitoring
n=34 Participants
Intra-operative neuromonitoring (XLTEK/NATUS EP Protektor): Device: Intra-operative neuromonitoring A XLTEK/NATUS EP Protektor machine (at MGH) or a Cadwell Cascade Elite neuromonitoring machine (at BWH), both FDA approved for intra-operative neuromonitoring, will deliver the electrical stimulus applied transcranially to stimulate the motor cortex, while motor evoked responses will be recorded from different myotomes from both upper limbs. Also the same equipment will deliver electrical stimulus to stimulate peripherally the median and ulnar nerves at the wrists, with recording of the thalamocortical potentials in the scalp channels.
Age, Categorical
<=18 years
3 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
30 Participants
n=5 Participants
Age, Categorical
>=65 years
1 Participants
n=5 Participants
Age, Continuous
28.4 years
n=5 Participants
Sex: Female, Male
Female
6 Participants
n=5 Participants
Sex: Female, Male
Male
28 Participants
n=5 Participants

PRIMARY outcome

Timeframe: up to 24 weeks after the procedure

Nerve palsy of any nerve(s) in the operative upper extremity.

Outcome measures

Outcome measures
Measure
Intra-op Neuromonitoring
n=34 Participants
Intra-operative neuromonitoring (XLTEK/NATUS EP Protektor): Device: Intra-operative neuromonitoring A XLTEK/NATUS EP Protektor machine (at MGH) or a Cadwell Cascade Elite neuromonitoring machine (at BWH), both FDA approved for intra-operative neuromonitoring, will deliver the electrical stimulus applied transcranially to stimulate the motor cortex, while motor evoked responses will be recorded from different myotomes from both upper limbs. Also the same equipment will deliver electrical stimulus to stimulate peripherally the median and ulnar nerves at the wrists, with recording of the thalamocortical potentials in the scalp channels.
Neurologic Complication Rate After Latarjet Procedure
7 participants

Adverse Events

Intra-op Neuromonitoring

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. Jon J.P. Warner, Chief of Shoulder Service MGH, Harvard Professor of Orthopaedics.

Massachusetts General Hospital

Phone: 617-724-3140

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place