Accuracy of Oximeters With Hypoxia and Methemoglobin or Carboxyhemoglobin

NCT ID: NCT01583634

Last Updated: 2014-10-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

9 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-09-30

Study Completion Date

2014-10-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Accuracy of the oximeter.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The conventional pulse oximeter has been a standard in clinical care for non-invasive hemodynamic monitoring, which only measures the arterial blood oxygenation. There are many clinical situations where tissue hypoxia may exist despite normal values obtained by conventional pulse oximeter. This can be cause by inadequate monitoring of oxygen demand (i.e. venous oxygen saturation) of the tissues.

The existing method for venous blood oxygenation monitored is either through an invasive fiber optic catheter, or intermittently by blood sampling and CO-oximetry. However, catheterization can be costly and can include inherent risks. Therefore, due to the inherent risks of catheterization, venous oximetry is limited only to those critically ill patients. The clinical application of venous oximetry is numerous, including severe sepsis and septic shock, severe trauma and hemorrhagic shock, and heart failure and cardiac arrest.

More complete information on patient hemodynamics can be provided by non-invasively monitoring of venous blood oxygenation.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy Volunteers

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Healthy volunteers

9 subjects (male and female)

Mespere Oximeter

Intervention Type DEVICE

Mespere oximeter provides non-invasive venous blood oxygen saturation.

Radiometer OSM-3 Co-Oximeter

Intervention Type DEVICE

OSM-3, a Radiometer manufactured hemoximeter, is intended for the photometric determination of hemoglobin.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Mespere Oximeter

Mespere oximeter provides non-invasive venous blood oxygen saturation.

Intervention Type DEVICE

Radiometer OSM-3 Co-Oximeter

OSM-3, a Radiometer manufactured hemoximeter, is intended for the photometric determination of hemoglobin.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Healthy volunteers between the ages of 21 and 49 years of either gender

Exclusion Criteria

* smokers
* pregnancy
* any chronic medical condition including heart disease, hypertension, pulmonary disease, liver or kidney disease
* obesity
* evidence of abnormal neck vein anatomy
Minimum Eligible Age

21 Years

Maximum Eligible Age

49 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mespere Lifesciences Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Philip E Bickler, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

University of California, San Francisco

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of California, San Francisco, Induced Hypoxia Lab

San Francisco, California, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MLS STP-9100001

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Pulse Oximeter Test
NCT03569163 COMPLETED
Pulse Oximeter Hypoxia
NCT04562584 COMPLETED NA
OM2 Motion Verification Study
NCT06415786 COMPLETED