Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
37 participants
INTERVENTIONAL
2012-03-31
2014-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The TAVR procedure consists in replacing the diseased aortic valve by a new artificial valve. The new valve is put into place using a long, thin tube called a catheter that is inserted into a small incision (cut) in the patient's groin and threaded through his/her arteries up to the heart.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation
NCT02536196
accuRate Evaluation of Benefit With Optimal Medical Treatment With or Without Transcatheter Valve Repair of PARADOXical Low Flow Low Gradient Aortic Stenosis
NCT03863132
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
NCT01531374
"TARGET 2.0 Study": Safety and Performance of the Cardiovalve TR Replacement System
NCT07334691
A Prospective, Multicenter, Observational Study of the Safety and Efficacy of Emergency Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis
NCT07108478
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The TAVR procedure consists in replacing the diseased aortic valve by a new artificial valve. The new valve is put into place using a long, thin tube called a catheter that is inserted into a small incision (cut) in the patient's groin and threaded through his/her arteries up to the heart.
During the TAVR procedure, there is a risk that an abnormal particle (called embolism) could break off from inside the arteries and travel to the brain. The embolism could be made of clumps of blood (clots), air, part of your body tissue, or part of a medical device. If the embolism is carried through the blood to the brain, it could cause a stroke or other neurological (brain) problems. A stroke happens when blood flow to a part of the brain is blocked, causing brain cells to die.
The Keystone Heart Embolic Deflection Device has been developed to prevent an embolism from going to the brain and causing a stroke or other brain damage. The device is a wire mesh filter that covers the vessels that carry blood to brain, deflecting any any blood clots or other materials away from the patient's brain and towards the lower body, where they are less likely to cause harm.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Keystone Heart Embolic Deflection Device
Protected Transcatheter Aortic Valve Replacement
Keystone Heart Embolic Deflection Device
The Keystone Heart Embolic Deflection Device is used in the aortic arch to deflect and to reduce embolic material (debris/thrombus) to the cerebral/carotid arteries during endovascular procedures.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Keystone Heart Embolic Deflection Device
The Keystone Heart Embolic Deflection Device is used in the aortic arch to deflect and to reduce embolic material (debris/thrombus) to the cerebral/carotid arteries during endovascular procedures.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patient meets indications for TAVR procedure.
3. The patient is willing to comply with protocol-specified follow-up evaluations.
4. The patient, or legally authorized representative, has been informed of the nature of the study, agrees to its provisions and has provided written informed consent, approved by the appropriate Medical Ethics Committee or Institutional Review Board.
Exclusion Criteria
2. Pregnant or nursing subjects and those who plan pregnancy in the period up to 1 year following index procedure. Female subjects of child-bearing potential must have a negative pregnancy test done within 7 days prior to index procedure per site standard test.
3. Patients with known diagnosis of acute myocardial infarction (AMI) within 72 hours preceding the index procedure (according to definition) or AMI \>72 hours preceding the index procedure, in whom creatine kinase and creatine kinase have not returned to within normal limits at the time of procedure.
4. Patients who are currently experiencing clinical symptoms consistent with new onset AMI, such as nitrate-unresponsive prolonged chest pain.
5. Patients with impaired renal function (estimated Glomerular Filtration Rate \[estimated Glomerular Filtration Rate\] \<30, calculated from serum creatinine by the Cockcroft-Gault formula)
6. Patients with a platelet count of \<100.000 cells/mm³ or \> 700.000 cells/mm³ or a white blood cell \< 3000 cells/mm³ within 7 days prior to index procedure.
7. Patients with a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated, or who will refuse transfusion.
8. Patients who have received any organ transplant or are on a waiting list for any organ transplant.
9. Patients with known other medical illness or known history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation or is associated with a life expectancy of less than one year.
10. Patients with known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, nitinol, stainless steel alloy, and/or contrast sensitivity that cannot be adequately pre-medicated.
11. Patients with a history of a stroke or transient ischemic attack (TIA) within the prior 6 months.
12. Patients with an active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the prior 6 months.
13. Patients presenting with cardiogenic shock.
14. Patients with severe peripheral arterial disease that precludes 9 French sheath vascular access.
15. Patients with documented friable or mobile atherosclerotic plaque in the aortic arch.
16. Patients with contraindication to cerebral MRI.
17. Patients who have a planned treatment with any other investigational device or procedure during the study period
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Keystone Heart
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Michael Mullen, Md.
Role: PRINCIPAL_INVESTIGATOR
The Heart Hospital, London, UK
References
Explore related publications, articles, or registry entries linked to this study.
Baumbach A, Mullen M, Brickman AM, Aggarwal SK, Pietras CG, Forrest JK, Hildick-Smith D, Meller SM, Gambone L, den Heijer P, Margolis P, Voros S, Lansky AJ. Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study. EuroIntervention. 2015 May;11(1):75-84. doi: 10.4244/EIJY15M04_01.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
DEFLECT I
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.