Cardiac Magnetic Resonance Imaging Guided Left Ventricular Lead Placement
NCT ID: NCT01417624
Last Updated: 2011-08-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE3
70 participants
INTERVENTIONAL
2011-08-31
2013-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The implantation of the special pacemaker requires three leads (wires) to be inserted within the heart. Currently this is undertaken under X-ray guidance. Some patients may have scarring of the heart muscle due to previous heart attacks or their underlying condition. The X-ray technique cannot see this and therefore the doctor may implant the lead in such an area of scar tissue. Cardiac magnetic resonance imaging (CMR) can demonstrate these areas of scar. The study aims to investigate whether CMR can better predict where the wires should be placed. The CMR pictures will be taken before the patient has the special pacemaker implanted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Cardiac Resynchronisation Therapy In Patients With Heart Failure: Mechanistic Insights From Cardiac MRI And Electroanatomical Mapping
NCT04322877
Combining Myocardial Strain and Cardiac CT to Optimize Left Ventricular Lead Placement in CRT Treatment
NCT01426321
Image Guided Mapping for Cardiac Pacing Intervention
NCT01638754
A Comparison of Two Techniques for Choosing the Best Place to Put a Pacing Lead for Cardiac Resynchronisation Therapy
NCT02061241
Tailoring Pacemaker Output to Physiology in Chronic Heart Failure
NCT03781427
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The mechanism by which CRT exerts its clinical benefits is fundamentally through the correction of mechanical dyssynchrony. However, despite much research in this area the optimal measures of dyssynchrony for the selection of suitable candidates for CRT have not been established. The current guidelines were revised in light of the PROSPECT trial which failed to prove validity and reproducibility in complex echocardiographic variables of dyssynchrony.3 The 12 lead electrocardiogram (ECG) remains the most widely used criterion for the assessment of dyssynchrony in patients being considered for CRT, with patients with a broad QRS complex (\>150ms) appearing to benefit the most.4, 5
Although the definition of left bundle branch block (LBBB) is well established, the precise electrophysiological characteristics remain poorly understood. An arbitrary 'cut off' of 120 milliseconds was recommended by the New York Heart Association (NYHA) in 1948 for its definition.6 This has subsequently become enshrined in the literature. The presence of LBBB, a heterogeneous entity, is associated with both electrical and mechanical abnormalities within the left ventricle.7 Septal and lateral wall delay frequently occur in this setting, with delayed activation of the lateral LV wall forming the basis for bi-ventricular pacing. It is well documented within populations with left ventricular impairment that there is prolongation of the QRS complex which is associated with an adverse prognosis.8
The success of CRT is reliant upon achieving an acceptable position of the left ventricular lead during implantation. The LV lead position needs to be anatomically stable to minimise the risk of lead displacement and also to avoid diaphragmatic capture. Furthermore, patients with myocardial scar tissue in the lateral LV segments as detected on CMR are known to have a worse outcome following CRT 9 and pacing such sites may potentially be pro-arrhythmic.10 It is not known whether CMR guided placement of the LV lead in order to avoid sites of myocardial scar and fibrosis can result in an improved clinical outcome in these patients.
A recently published study corroborates that myocardial scar in the region of activation of the LV lead may have a detrimental effect on the delivery of CRT. A consecutive series of 397 patients with ischaemic cardiomyopathy were imaged prior to the implantation of CRT. Using the complex echocardiographic technique of 'speckle tracking', myocardial scar was demonstrated to have an adverse effect on patients' outcomes. It remained an independent predictor of adverse clinical outcome. Notably due to the complexity of the technique, the presence of myocardial scar was validated using CMR.11
CRT response is a contentious subject. It is well recognised within the literature that approximately 30-40% of patients do not appear to improve clinically following CRT implantation.12 However, the inter-study variability of what has been considered as a marker of response has been wide and several different variables have been utilised.13 Several of the studies have also been small, single centre, and non-randomised. There is currently a lack of consensus in what constitutes 'response' vs 'non-response' following CRT, which may be either defined in terms of markers of LV reverse remodelling or changes in the clinical indices of heart failure or a combination of them both. In an effort to rationalise the endpoints of CRT trials, clinical composite scores have been devised inclusive of both imaging based and clinical endpoints. However, the correlation between both LV remodelling and clinical endpoints when compared using correlation coefficients is marginally better than chance. The realisation that clinical improvement post CRT implantation does not necessarily accompany mechanical remodelling has also confused the issue.
Rationale for Study The aim of the present study is to provide pilot data, the results of which should increase our understanding of the mechanisms by which CRT improves clinical outcomes in patients with heart failure.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Control Group - Standard
This will be a randomised controlled unblinded prospective study recruiting patients in sinus rhythm with LBBB (QRS width ≥ 120ms) and a LV ejection fraction of below 35% who meet the current guidelines for CRT implantation. Patients will be randomised to one of two groups (1:1 randomisation)
Conventional LV lead placement - the LV lead will be placed according to standard techniques without knowledge of the patient's CMR findings
CMR Guidance in terms of guiding LV lead implantation
Following randomisation, the optimal position of the LV lead will be determined either according to current standard criteria (as proposed by the primary operator) or with CMR guidance.
The CRT device will be implanted using established conventional techniques. The CMR study will be performed pre-implantation only. The distribution of myocardial scar and fibrosis will be derived from this study. A CMR venogram will also be generated and the suggested optimal venous tributaries of the great cardiac vein will be identified from discussion between the principal investigator and senior CMR physician. This information will be used for those in the active arm only.
Active CMR guided Arm
This will be a randomised controlled unblinded prospective study recruiting patients in sinus rhythm with LBBB (QRS width ≥ 120ms) and a LV ejection fraction of below 35% who meet the current guidelines for CRT implantation.Patients will be randomised to one of two groups (1:1 randomisation):
CMR guided LV lead placement - an expert panel will decide pre-operatively the optimal branch of the coronary sinus for LV lead placement based on the presence of myocardial scar tissue and coronary sinus anatomy. The operator will informed as to the optimal vein to target for delivery of the LV lead. Should this be technically unfeasible (e.g. due to pacing considerations or stability of LV lead position), then the most suitable vein will be used at the time of implantation.
CMR Guidance in terms of guiding LV lead implantation
Following randomisation, the optimal position of the LV lead will be determined either according to current standard criteria (as proposed by the primary operator) or with CMR guidance.
The CRT device will be implanted using established conventional techniques. The CMR study will be performed pre-implantation only. The distribution of myocardial scar and fibrosis will be derived from this study. A CMR venogram will also be generated and the suggested optimal venous tributaries of the great cardiac vein will be identified from discussion between the principal investigator and senior CMR physician. This information will be used for those in the active arm only.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CMR Guidance in terms of guiding LV lead implantation
Following randomisation, the optimal position of the LV lead will be determined either according to current standard criteria (as proposed by the primary operator) or with CMR guidance.
The CRT device will be implanted using established conventional techniques. The CMR study will be performed pre-implantation only. The distribution of myocardial scar and fibrosis will be derived from this study. A CMR venogram will also be generated and the suggested optimal venous tributaries of the great cardiac vein will be identified from discussion between the principal investigator and senior CMR physician. This information will be used for those in the active arm only.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age \>18 years old
* Successful CRT implantation (with or without a defibrillator)
* NYHA Class III-IV Heart Failure (or NYHA II with NYHA III/IV symptoms in the preceding 12 months)
* LVEF \<35% (Calculated using echocardiography or Cardiac MR) at the time of implantation
* QRS duration \> 120ms with Left Bundle Branch Block morphology on ECG
* Sinus Rhythm
* Optimal Tolerated Medical Therapy for Heart Failure
Exclusion Criteria
* Active malignant disease and recent (\<5 years) malignant disease
* Prior Heart Transplant
* Recent history of unstable angina, acute coronary syndrome or myocardial infarction within three months of enrollment into the study
* Pregnancy
* Failure to participate in consent process
* Atrial Fibrillation
* Conventional pacemaker in situ
* Heart Failure requiring constant intravenous therapy including diuretics and/or inotropes
* Recent revascularisation procedure i.e. coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) within the last three months
* Contraindications to a CMR study
18 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Royal Brompton & Harefield NHS Foundation Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Royal Brompton Hospital, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Rakesh Sharma, MRCP PhD
Role: PRINCIPAL_INVESTIGATOR
Royal Brompton & Harefield NHS Foundation Trust
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Royal Brompton Hospital
London, London, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Related Links
Access external resources that provide additional context or updates about the study.
Homepage for Royal Brompton \& Harefield NHS Foundation Trust
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RBH2011HS008B
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.