Prospective Comparative Study of Refractive Outcome of STAAR and Alcon Toric Intraocular Lenses
NCT ID: NCT01121861
Last Updated: 2010-05-12
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
100 participants
INTERVENTIONAL
2007-06-30
2009-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Rotational Stability After Nanoflex Collamer Toric Intraocular Lens Implantation in Astigmatic Patients
NCT02412215
Astigmatism Management in Cataract Surgery With the AcrySof Toric Intraocular Lens
NCT01075542
Pilot Study of AcrySof® IQ ReSTOR® +3.0 D Multifocal Toric Intraocular Lens (IOL)
NCT01200511
Low Cylinder Toric
NCT00732030
The Long-term Outcome After Toric Intraocular Lens Implantation
NCT05465447
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Using partial coherence interferometry has led to more accurate biometry and consequently more predictable spherical results. This also helped paved the way for satisfactory correction of presbyopia with multifocal intraocular lenses (IOL).
Astigmatism is also an important component of the refractive equation. Estimates of the incidence of significant, naturally occurring astigmatism vary widely from 7.5% to 75%1. It is thought that 3% to 15% of eyes may have 2 or more diopters (D) of astigmatism2. Many surgeons would agree that astigmatism of greater than 0.5 D will have visual consequences such as symptoms of ghosting and shadows and they now aim for both spherical and astigmatic outcomes of +/ - 0.5 D3.
Several methods have been developed to address and reduce preexisting astigmatism. While corneal relaxing incisions for astigmatic correction can be unpredictable and highly surgeon dependent, the opposite is true for toric IOLs. The refractive results associated with the use of toric IOLs are likely to be more predictable as it is independent of corneal wound healing. The implantation of an IOL is also less surgeon dependent. Other advantages associated with toric IOLs include the absence of need for any additional astigmatic correction procedure during cataract surgery, faster visual recovery as well as the reversibility of the procedure.
Studies have been carried out to evaluate the efficacy and rotational stability of the STAAR AA4203 TF/TL toric IOL since its FDA approval in November 1998. These trials have only been carried out on Caucasian eyes and have shown a significant reduction in the pre-existing refractive astigmatism, improvement of postoperative unaided visual acuity as well as excellent refractive as well as rotational stability (latter especially so with the TL model). Ruhswurm et al.6 reviewed 37 eyes with STAAR toric IOL over a mean duration of 20.3 months and found that 78.4% of eyes had residual refractive astigmatism within +/- 1.00 D and 48.6% within +/- 0.50D. 83.4% of these eyes achieved best-corrected visual acuity of 20/40 or better. Sun et al.7 demonstrated improved unaided visual outcome between eyes with toric (130 eyes; 86.4% with visual acuity 20/40 or better) and spherical IOL (51 eyes; 76% with visual acuity 20/40 or better). Similar results have also been obtained with the Alcon toric IOL. In Horn et al.9, the clinical trial results of 250 patients with Alcon toric IOL have been described, demonstrating good unaided visual acuity of 20/25 or better at the 6-month postoperative visit (66% of patients with unilateral toric implant and 97% with bilateral implants). 97% of these toric patients achieved spectacle freedom for distance vision, compared to 50% of control patients. It is well documented that the rotational stability of these toric IOL is crucial to the efficacy of astigmatic reduction. Theoretical calculations show that an estimated 1/3 of astigmatic correction is lost if the IOL is rotated by 10 degrees off axis, as well as potential worsening of preoperative astigmatism in the presence of more than 30 degrees of off-axis rotation. Toric IOL stability is dependent on multiple factors, one of which is the capsular bag size. Vass et al.11 showed a good correlation between axial length and capsular bag diameter (CBD), especially so in eyes with axial lengths of less than 25.0mm. On the other hand, highly myopic eyes are not shown to have a greater risk of having a larger CBD than those with normal axial lengths. A formula derived to calculate a predicted CBD (CBDp) showed that values greater than 10.3mm are likely to have existing larger CBD and hence benefit from implantation of longer toric IOL due to better centration.
To date, there has not been any trial carried out to evaluate the results of toric IOL in either our local population or in East Asia. There has also not been any prospective clinical trial conducted to compare the difference (if any) between a plate-haptic and loop-haptic toric IOL. Hence, we set out to evaluate and compare the efficacy, safety, predictability and stability of the STAAR and Alcon toric IOL in Asian eyes.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Phacoemulsification with implantation of toric IOL
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Regular corneal astigmatism of at least 1.25D and not exceeding 2.0D.
3. Age range between 21-80 years.
4. Informed consent of surgery and implantation of toric IOL obtained.
Exclusion Criteria
2. Regular corneal astigmatism less than 1.0D.
3. Presence of other ocular diseases that may compromise on the visual outcome such as glaucoma, retinal diseases, macular diseases and corneal diseases.
21 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Singapore National Eye Centre
OTHER_GOV
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Wei Han Chua, FRCS, FAMS
Role: PRINCIPAL_INVESTIGATOR
Singapore National Eye Centre
Jocelyn Chua, MRCS, MMED
Role: PRINCIPAL_INVESTIGATOR
Singapore National Eye Centre
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Singapore National Eye Centre
Singapore, , Singapore
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Horn JD. Status of toric intraocular lenses. Curr Opin Ophthalmol. 2007 Feb;18(1):58-61. doi: 10.1097/ICU.0b013e328011f9bf.
Till JS, Yoder PR Jr, Wilcox TK, Spielman JL. Toric intraocular lens implantation: 100 consecutive cases. J Cataract Refract Surg. 2002 Feb;28(2):295-301. doi: 10.1016/s0886-3350(01)01035-5.
Chang DF. Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases. J Cataract Refract Surg. 2003 May;29(5):935-40. doi: 10.1016/s0886-3350(02)01843-6.
Sun XY, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology. 2000 Sep;107(9):1776-81; discussion 1781-2. doi: 10.1016/s0161-6420(00)00266-9.
Patel CK, Ormonde S, Rosen PH, Bron AJ. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. Ophthalmology. 1999 Nov;106(11):2190-5; discussion 2196. doi: 10.1016/S0161-6420(99)90504-3.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
R536/24/2007
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.