EZ Blocker Versus Left Sided Double-lumen Tube

NCT ID: NCT01073722

Last Updated: 2011-05-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE4

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2010-02-28

Study Completion Date

2011-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Lung isolation is used to achieve one lung ventilation to facilitate thoracic surgery. Two methods are commonly used, a double lumen tube (DLT) or a bronchial blocker introduced through a single lumen tube. However, both techniques have advantages and disadvantages. Briefly, the DLT can be positioned faster and remains firmly in place, but is sometimes difficult or even impossible to introduce. The DLT is larger than a conventional single lumen tube and the incidence of postoperative hoarseness and airway injuries is higher. Compared to the DLT, bronchial blocking devices are more difficult to position and need more frequent intraoperative repositioning. These disadvantages of the existing devices for lung isolation prompted further development of the bronchial blocker concept. The design of a new Y shaped bronchial blocker, the EZ- Blocker® (AnaesthetIQ BV, Rotterdam, The Netherlands) (EZB), combines the advantages of both lung isolation techniques. The aim of the study is to compare in a randomised, prospective way the ease of placement, the incidence of malpositioning and the quality of lung deflation of a left DLT and a EZB. Secondly, the incidence and severity of damage to laryngeal, tracheal and bronchial structures caused by the use of the DLT or the EZB is a target of the study.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

One-lung Ventilation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Caregivers

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Left double lumen tube

Traditionally, single lung ventilation is obtained with a double lumen tube (DLT). In our institution a polyvinyl DLT (Broncho-cath, Mallinckrodt,) without carinal hook, is used. This type of tube exists of a tube with two lumen with two distal cuffs. One lumen (called the bronchial lumen) extends some distance further, has a slight curvature and has a small blue cuff. The other lumen (called the tracheal lumen) has a larger cuff. A DLT tube exists in four sizes and one can choose in a left or a right configuration. Almost always, we use a left sided DLT. A DLT has a much larger diameter than a standard single lumen endotracheal tube

Group Type ACTIVE_COMPARATOR

Placement of double lumen tube for one-lung ventilation

Intervention Type DEVICE

The gold standard for lung isolation is the use of a double lumen tube (DLT). A DLT is a bifurcated tube with a bronchial and a tracheal lumen.

EZ-blocker

The EZ-blocker (EZB) is a semi-rigid catheter but it has two distal extensions, both with an inflatable cuff and a central lumen. It is intended for use in combination with a standard single lumen tube. After the EZB is advanced trough the distal end of the single lumen tube, both extensions spread out and find their way in the left and right main stem bronchi. The place where the two extensions are attached to the shaft now rests on the carina. Fiber optic bronchoscopy should be used for proper positioning. After placement of the EZB, one of the cuffs can be inflated to obtain lung separation under direct visual inspection with fiber optic bronchoscopy.

Group Type ACTIVE_COMPARATOR

Placement of EZ- Blocker for one-lung ventilation

Intervention Type DEVICE

Bronchial blockers are balloon-tipped semi-rigid catheters. Different types are available. They are not easy to put in position and frequently dislocates during repositioning of the patient or during surgical manipulation. To solve these problems, a novel type of bronchus blocker, i.e. the EZ- Blocker® is developed. The EZB is also a semi-rigid catheter but it has two distal extensions, both with an inflatable cuff and a central lumen. These improvements owe to the fact that the blocker anchors itself on the carina with the two extensions.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Placement of double lumen tube for one-lung ventilation

The gold standard for lung isolation is the use of a double lumen tube (DLT). A DLT is a bifurcated tube with a bronchial and a tracheal lumen.

Intervention Type DEVICE

Placement of EZ- Blocker for one-lung ventilation

Bronchial blockers are balloon-tipped semi-rigid catheters. Different types are available. They are not easy to put in position and frequently dislocates during repositioning of the patient or during surgical manipulation. To solve these problems, a novel type of bronchus blocker, i.e. the EZ- Blocker® is developed. The EZB is also a semi-rigid catheter but it has two distal extensions, both with an inflatable cuff and a central lumen. These improvements owe to the fact that the blocker anchors itself on the carina with the two extensions.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Broncho-cath (Mallinckrodt) EZ-blocker (AnaesthetIQ BV, Rotterdam, The Netherlands)

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* ASA physical status 1-3 patients
* Patients scheduled for surgery requiring a left sided DLT for single lung ventilation

Exclusion Criteria

* Contraindications are lesions along the path of the left sided double lumen tube or the EZB
* Tracheal or mainstem bronchial stenosis
* Distorted carinal anatomy,
* Anticipated difficult intubation (Mallampatti score ≥ 3)
* History or presence of tracheostoma
* Patients who require absolute lung separation
* Patients who require sleeve resection of mainstem bronchus
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Radboud University Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Radboud University Nijmegen Medical Center

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jo Mourisse, Dr.

Role: PRINCIPAL_INVESTIGATOR

Department of anesthesiology, pain and palliative medicine of the Radboud University Nijmegen Medial Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Anesthesiology, Pain and Palliative Medicine of the Radboud University Nijmegen Medical Centre

Nijmegen, Gelderland, Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NL30799,091,09

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

LEVANT 2 Safety Registry
NCT01790243 COMPLETED NA