Prospective Evaluation of Intrafractional and Interfractional Cervical Motion During External Beam Radiation for Intact Cervical Cancer by the Calypso® 4D Localization System™
NCT ID: NCT00907634
Last Updated: 2013-10-24
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
OBSERVATIONAL
2009-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The investigational portion of this study includes (1) daily cone beam CT scans to confirm transponder placement and evaluate tumor changes during treatment and (2) tracking movement of the cervix during daily radiation treatment.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Currently, there is limited knowledge of cervical organ motion. Previous studies have evaluated interfractional cervical motion \[daily set-up variation, i.e. the location of the cervix on Day 1 vs. Day 2 or Day 30 of radiation treatment\] with weekly CT and MRI scans or localization of fiducial markers evaluated by fluoroscopy daily before radiation therapy. There is no published literature regarding intrafractional cervical motion \[motion during a single radiation treatment\]. We propose a prospective clinical trial utilizing the Calypso® 4D Localization System™ to evaluate intrafractional and interfractional cervical motion for intact cervical cancer.
The Calypso® 4D Localization System™ is an FDA approved tumor localization system for adjunctive use in patients undergoing radiation therapy for prostate cancer. The system is designed to provide accurate, objective, and continuous 3-dimensional localization of the treatment target for patient alignment and target position monitoring relative to the isocenter of the linear accelerator. The Calypso system consists of implantable electromagnetic transponders, each with a unique resonant frequency. An array is placed over the patient and remains in place during radiation delivery. Source coils in the array emit electromagnetic signals that excite the transponders identifying the position of each individual transponder. The transponder position can be continuously monitored throughout treatment delivery reporting transponder motion in lateral, superior-inferior (SI), and anterior-posterior (AP) directions.
Our goal is to enroll 10 patients over a 1-2 year time period with intact cervical cancer (Stage IB-IVA) who will receive definitive radiation therapy at Emory University Hospital and Emory Crawford Long Hospital. Two Calypso beacons will be attached within a cervical "Smit" sleeve \[1 superior, 1 inferior\] which will be placed within the cervical os prior to CT simulation (radiation planning session). The cervical sleeve will be sutured in with 2 stitches. The location of the transponders will be tracked throughout the treatment delivery. Daily cone beam CT on the radiation treatment machine will also be utilized to confirm transponder placement and evaluate tumor volume changes during the treatment course. There will be no treatment field modifications based on cervical (transponder) displacement. While enrolled on this study, patients will be treated with the current standard of care treatment: 5 weeks of external beam radiation with concurrent weekly cisplatin and followed a focal radiation "boost" using intracavitary brachytherapy. The 5 weeks of external beam radiation therapy will be delivered with a conventional 4-field technique to the whole pelvis for a total of 45Gy at 1.8 Gy per fraction. All external beam radiation treatments will be delivered at the Emory Clinic, Clifton Road. The cervical sleeve will be removed following the external beam portion of therapy.
The calypso beacons will be provided free of charge for this study and there will be no additional costs to the patient or the Radiation Oncology Department for patients enrolling in this study. No additional risks are anticipated for patients enrolled in this study compared to the current standard of care treatment. The only "tests" that are part of our protocol that are outside of the standard of care for the treatment of intact cervical cancer would be the use of the (1) Calypso array used to localize the calypso "beacons" and (2) daily cone-beam CT scans to evaluate cervical cancer response to therapy. The Radiation Oncology department regularly uses both systems for patient set-up for other solid tumors and there will be no additional charge for these tests.
We believe this study will greater improve our current knowledge of cervical cancer motion and tumor regression during radiation therapy. There is concern that smaller radiation fields, as would be delivered with IMRT could underdose portions of the tumor resulting in inadequate local tumor control and compromising cure. As a result of this study will be able to infer if IMRT is a safe and reasonable treatment option for patients with intact cervical cancer. Knowledge of the extent and direction of cervical motion will also help determine IMRT treatment margins.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Karnofsky Performance Score 60-100
Exclusion Criteria
* Karnofsky Performance Score \< 60
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Emory University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Peter J. Rossi, MD
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Peter Rossi, MD
Role: PRINCIPAL_INVESTIGATOR
Emory University
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EmoryCervicalMotion
Identifier Type: OTHER
Identifier Source: secondary_id
IRB00013078
Identifier Type: -