Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography

NCT ID: NCT00532051

Last Updated: 2024-02-12

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

690 participants

Study Classification

OBSERVATIONAL

Study Start Date

2011-04-30

Study Completion Date

2026-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The long-term goal of this project is to utilize very high-speed optical coherence tomography (OCT) technology to guide surgical treatments of corneal diseases. OCT is well known for its exquisite resolution, but until recently it has not had sufficient speed to capture the shape of the cornea because of eye motion during OCT scanning. The development of Fourier-domain (FD) OCT technology has made the requisite speed possible.

The objective of this project is to develop methods for imaging the cornea with an FD-OCT system that will precisely measure corneal shape and use this information to guide surgery. Cataract surgery in patients with previous laser vision correction often leads to significant near- or far-sightedness, a problem that could be resolved by using a more accurate intraocular lens power selection formula based on the measurement of corneal refractive power with OCT.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study is about an imaging method called Optical Coherence Tomography (OCT) which provides detailed cross-sectional (layered) views of structures in the eye. The OCT system scans a beam of light across the eye to take a picture. OCT provides a more detailed image than other imaging methods of the eye such as ultrasound, CT scan (computed tomography) and MRI (magnetic resonance imaging). In addition, OCT imaging does not touch the eye. OCT is routinely used in imaging structures in the back of the eye (retina) and cornea. This study uses high-speed FDA approved OCT systems. The proposed research plan is a combination of clinical studies and software development to be performed synergistically. Clinical studies will provide OCT images for image processing software development and testing. The image processing software will provide automated measurement of anatomic parameters essential for clinical use.

Cataract extraction and IOL implantation is the most common eye surgery. The power of the IOL implant is calculated from 2 measurements: the axial eye length (AL) and keratometric power (K). The Holladay II formula also uses the external corneal diameter ("white-to-white" or WTW) and anterior chamber depth (ACD). These formulae work well (±0.5D) in normal eyes. However, these formulae can leads to biased and unpredictable refractive results in eyes that had refractive surgery procedures such as LASIK, PRK, and RK. With a large number of patients undergoing refractive surgery every year, the problem is becoming more severe.

The conventional IOL formulae fail because several inherent assumptions are no longer true in the eye that had refractive surgery. These assumptions are: 1) The corneal refractive power is uniform. 2) The anterior and posterior corneal power has a fixed relationship such that the overall corneal refractive power can be calculated from the anterior keratometry (or topography) using the keratometric index. 3) The position of IOL can be predicted by K with or without additional information such as WTW and ACD.

Relative to the posterior curvature, the anterior curvature becomes flatter after myopic correction and steeper after hyperopic correction with LASIK or PRK. To adapt the conventional IOL formulae to this situation, most surgeons use rigid contact lens over-refraction to calculate an "effective K." However, the accuracy of refraction in cataract patients is poor due to poor vision. Alternatively, one could use a historical method to calculate the effective K from pre-refractive surgery values. However, those measurements are often no longer available. If many years have lapsed, the historical value may no longer accurately reflect the current shape of the cornea.

The axial position of the IOL is determined by the positions of lens zonules and capsule which is in turn related to the corneal curvature (K) in the normal eye. A flatter cornea (lower K) is usually associated with a larger anterior segment, where the lens apparatus is located further back. A more complex model that also uses a separately measured white-to-white corneal diameter may be even more accurate. In post-refractive surgery eyes, however, K is altered and no longer has the normal relationship with the size of the eye. One way to get around this is to enter the pre-refractive surgery K. However, this historical information is not always available. We believe that a better solution would be use an entirely different approach that does not depend on the 3 above assumptions at all. Since OCT can separately measure the corneal anterior and posterior surfaces and AC and lens dimensions, we believe it has the potential of being the basis of a much better IOL calculation formula.

Previously we developed a method to measure both anterior and posterior corneal surface curvatures and obtain more accurate corneal power measurements than conventional keratometry, which only measures the anterior surface. This was the basis of an OCT-based intraocular lens (IOL) formula that showed better results than other formulas for post-myopic LASIK cataract surgery. However, this formula was only on par with the best regression-based formulas in eyes with previous hyperopic LASIK or radial keratectomy (RK), because IOL position prediction error and higher-order corneal aberration limited the accuracy of optical calculations in in these cases. We propose to improve IOL position prediction by using the long-range OCT that can image the entire anterior eye and accurately measure the lens equatorial position. We propose to more accurately determine corneal power in the presence of high aberration by developing ray tracing techniques based on ultrahigh-speed OCT mapping of corneal surfaces. Together, these new methods should improve IOL selection and refractive outcome for all types of eyes. In addition, we will develop a new OCT-based toric IOL formula that takes into account posterior corneal astigmatism, which is ignored in conventional keratometry.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cataract

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

OCT measurements

This study is about a new imaging method to study the front part of the eye. This imaging method is called Optical Coherence Tomography (OCT) which provides detailed cross-sectional (layered) views of structures in the eye. The OCT system scans a beam of light across the eye to take a picture. OCT provides a more detailed image than other imaging methods of the eye such as ultrasound, CT scan (computed tomography), and MRI (magnetic resonance imaging). In addition, OCT imaging does not touch the eye. OCT is routinely used in imaging structures in the back of the eye (retina) and cornea. This study uses high-speed FDA approved OCT systemsThe measurements from the OCT systems are used in selecting IOL power.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Manufacturer/Name OCT Technology 510(K) Optovue/RTVue-CAM Fourier-domain K071250 Bioptigen/Bioptigen Fourier-domain K063343 Zeiss/Visante Time-domain K051789

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* The subjects will be patients seeking cataract surgery with implantation of monofocal IOLs (including toric IOLs) but not multifocal or accommodative IOLs.
* Subjects will have had post-laser vision correction (LVC) such as previous LASIK, PRK, laser sub-epithelial keratectomy (LASEK), epi-LASIK (surface laser ablation under a microkeratome-created epithelial flap) or RK. The post-LVC group will be subdivided into those who have previous hyperopic LVC and those who have previous myopic LVC.

Exclusion Criteria

* Inability to give informed consent.
* Inability to maintain stable fixation for OCT imaging.
* Inability to commit to required visits to complete the study.
* Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Eye Institute (NEI)

NIH

Sponsor Role collaborator

Oregon Health and Science University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

David Huang

: David Huang, MD, PhD, Professor of Ophthalmology

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

David Huang, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Casey Eye Institute, Oregon Health & Science University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Casey Eye Institute, Oregon Health & Science University

Portland, Oregon, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Humberto Martinez, COT

Role: CONTACT

503-494-7712

Denny Romfh, OD

Role: CONTACT

503-494-4351

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Humberto Martinez, COT

Role: primary

503-494-7712

Denny Romfh, OD

Role: backup

503-494-4351

References

Explore related publications, articles, or registry entries linked to this study.

Wang L, Tang M, Huang D, Weikert MP, Koch DD. Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery. Ophthalmology. 2015 Dec;122(12):2443-9. doi: 10.1016/j.ophtha.2015.08.037. Epub 2015 Oct 14.

Reference Type DERIVED
PMID: 26459996 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

7R01EY018184-04

Identifier Type: NIH

Identifier Source: secondary_id

View Link

OHSU IRB #00006612-IOL

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Collagen Cross-linking in Keratoconus
NCT03760432 RECRUITING NA
McNeel Eye Center Corneal Crosslinking Study
NCT02921009 ACTIVE_NOT_RECRUITING NA
OCT-guided LALAK for KCN
NCT01901614 TERMINATED NA