Evaluation of the Bio-Seal Biopsy Track Plug

NCT ID: NCT00527722

Last Updated: 2012-08-07

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2/PHASE3

Total Enrollment

77 participants

Study Classification

INTERVENTIONAL

Study Start Date

2005-09-30

Study Completion Date

2008-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to demonstrate safety and effectiveness of the Bio-Seal Biopsy Track Plug in a clinical setting for use in lung biopsy procedures to reduce the rate of air leaks, commonly associated with the procedure. The Bio-Seal System is cleared in the U.S. with an indication for use as a lung biopsy site marker.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Air leaks are the most common problem after a lung biopsy. Air leaks can be mild to severe. Mild air leaks are monitored by chest x-ray and may go away by themselves. Air leaks can cause pain and require repeated x-rays, and in some cases the need for a tube to be inserted into the chest for drainage of the air.

If you agree to take part in this study, you will be randomly assigned (as in the toss of a coin) to 1of 2 groups. Participants in one group will receive the experimental lung plug after the lung biopsy. Participants in the other group will just have the standard lung biopsy without placement of the plug. There is an equal chance of being assigned to either group.

All participants will have the routine lung biopsy performed by their doctor with the aid of a computerized tomography (CT) scan. During a lung biopsy, a needle is inserted into the mass in the lung using the CT for guidance. A smaller needle is then inserted through the first needle to collect a sample of the tissue.

If you are assigned to receive the lung plug, it will be inserted into the track left when the biopsy needle is removed. The smaller sampling needle is removed, and the lung plug is inserted through the larger needle using a delivery tool that has a plunger to push the plug in place. The lung plug remains in the track left when the larger needle is removed.

Regardless of which group you are assigned to, you will be receive the same follow-up treatment. The rates of air leaks after the lung biopsy will be compared between 2 groups of participants. This will provide researchers with the data to learn if the lung plug should be used for all patients receiving a lung biopsy to decrease the number of air leaks.

Your doctor will watch you carefully for air leaks. You will have a chest x-ray about 1 hour after the procedure to again check for air leaks. If a leak is detected, you will receive the normal treatment for air leaks, which includes chest x-rays on a regular basis. If the air leak grows, you may need a chest tube placed for drainage. It is possible that this may require you to stay in the hospital overnight. In the most extreme cases, additional surgery may be needed to stop the air leak. Over time, your body will absorb the plug. A final x-ray will be taken 1 month after the biopsy to be sure that an air leak has not developed.

You will be asked to be in the study for 30 days. This will include the time you spend in the hospital for the biopsy and, if you have an air leak, the entire time you spend in the hospital, if it needs to be treated. In addition, you will return to your doctor the day following the biopsy and 30 days later to have a chest x-ray to look for any late air leaks.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Lung Cancer

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Lung Cancer Bio-Seal Track Plug Lung Biopsy Lung Plug Air Leaks

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pleural Plug

Experimental lung plug after the lung biopsy.

Group Type EXPERIMENTAL

Bio-Seal Track Plug

Intervention Type DEVICE

The lung plug will be inserted into the left track when the biopsy needle is removed. The smaller sampling needle is removed, and the lung plug is inserted through the larger needle using a delivery tool that has a plunger to push the plug in place. The lung plug remains in the track left when the larger needle is removed.

No Pleural Plug

The standard lung biopsy without placement of the plug.

Group Type ACTIVE_COMPARATOR

No lung plug

Intervention Type OTHER

Standard lung biopsy without placement of the plug.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Bio-Seal Track Plug

The lung plug will be inserted into the left track when the biopsy needle is removed. The smaller sampling needle is removed, and the lung plug is inserted through the larger needle using a delivery tool that has a plunger to push the plug in place. The lung plug remains in the track left when the larger needle is removed.

Intervention Type DEVICE

No lung plug

Standard lung biopsy without placement of the plug.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. The patient, or legal representative, must understand and provide written consent for the procedure
2. The patient has a non-calcified, radiologically suspicious opacity or lung nodule, including a metastatic lung module, or mass of at least 1.0 cm in size; as determined by CT scan equipped with measurement software. Suspicious nodules observed by CT scan are defined as non-calcified masses with convex borders, not known to be stable. Suspicious nodules can also be defined as masses demonstrating opacity on x-ray that are suspicious by radiographic or clinical means and require biopsy.
3. The patient must meet all medical conditions for lung biopsy;
4. The patient must be at least 18 years of age;

Exclusion Criteria

1. Patients with radiological findings of bullous emphysema, and the bullae are located near the intended area for biopsy. (Patients may enter the study who have radiological findings of bullous emphysema, as long as the cysts, blebs, or bullae are not in the area of the anticipated biopsy, and biopsy needle track).
2. Female patients who are pregnant. Note: patients of childbearing potential should have a pregnancy test no more than one week prior to the biopsy procedure, and be instructed to have no unprotected sexual intercourse after the test until the biopsy procedure is completed
3. Patients who are uncooperative or cannot follow instructions
4. Patients who are currently enrolled in another Investigational New Drug (IND) or Device Exemption (IDE) clinical investigation that has not completed the required follow-up period
5. Patients who cannot tolerate mild sedation, possibly secondary to poor respiratory status;
6. Patients with fungal infections (Patients with known or imaging evidence highly suggestive of pulmonary fungal infection)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

M.D. Anderson Cancer Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Sanjay Gupta, MD

Role: PRINCIPAL_INVESTIGATOR

M.D. Anderson Cancer Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

U.T.M.D. Anderson Cancer Center

Houston, Texas, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Zaetta JM, Licht MO, Fisher JS, Avelar RL; Bio-Seal Study Group. A lung biopsy tract plug for reduction of postbiopsy pneumothorax and other complications: results of a prospective, multicenter, randomized, controlled clinical study. J Vasc Interv Radiol. 2010 Aug;21(8):1235-43.e1-3. doi: 10.1016/j.jvir.2010.04.021.

Reference Type DERIVED
PMID: 20656223 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

http://www.mdanderson.org

The University of Texas M.D.Anderson Cancer Center

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2005-0268

Identifier Type: -