Emergency Egress and Information System for Persons With Vision Loss

NCT ID: NCT00262509

Last Updated: 2014-02-11

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

17 participants

Study Classification

INTERVENTIONAL

Study Start Date

2008-09-30

Study Completion Date

2009-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the research project is to develop and evaluate an emergency egress system for persons with visual impairment, which would use existing lighted exit signage to provide egress information at a distance of up to 100 feet.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The purpose of the proposed three-year research project is to develop and evaluate an emergency egress system for persons with visual impairment. This system would use existing lighted exit signage to provide egress information at a distance of up to 100 feet. The distance is the same as the required visibility distance of lighted exit signs for sighted persons. By offering egress information at an equivalent distance, the investigators hypothesize that people with visual impairment can approach the egress performance of sighted persons.

The information transmitted will be equivalent to what a sighted person obtains, namely, the direction of the exit door. In addition, a description of the exit route will be provided including the distance to the exit door; lighting conditions, hazards and obstacles that will be encountered on the exit route; the distance down to the street; and where on the street they will be when they get out of the building. A receiver worn by the person will include a tiny optical array to sense the direction of each exit sign. The receiver will also translate the transmitted signal into a spoken message. A low-profile stereo bone conduction headset will indicate the direction to each exit sign along a path to the exit door. For people with some hearing loss, this same low-profile headset will be used to simulate a light "tap" to one side or other of the head to indicate direction. Such directional "tapping" output may also prove effective when loud alarms are blaring.

The objectives are to:

1. develop Talking Exit Lights with a range of at least 100 feet,
2. write software for the user device to accurately indicate the direction of Talking Exit Lights and provide spoken messages,
3. optimize the user interface to make it easy and intuitive to use,
4. test the accuracy and reliability of the developed system in terms of transmission range and directional accuracy, and
5. conduct subject evaluations of the new system.

Two versions of transmitting exit signs will be developed:

1. a retro-fit design for existing fluorescent light exit signs, and
2. a Light Emitting Diode (LED) design for the LED exit signs now going into newly constructed buildings.

For the retro-fit version, Talking Lights, LLC, will modify the physical shape and size of their Talking Light digital ballast, making it a fully compatible replacement for existing exit sign ballasts. VA investigators will develop the LED version, designing and constructing a microprocessor-controlled system for storing and transmitting information using LEDs. Both designs will use secure power line communications to upload transmittal information to specific exit signs, each of which will have its own ID number. Finally, VA investigators will write software for the existing Talking Lights PocketPC receiver to interpret sensor signals, obtain sign location data, and convert this data into a stereo sound presentation of exit sign direction.

This development will be accomplished via a Cooperative Research and Development Agreement (CRADA) with Talking Lights LLC, which holds a patent on an electronic ballast that converts standard fluorescent bulbs into digital information transmitters. The company will also provide a PocketPC receiver that decodes their proprietary transmission signal, and a 5-sensor optical array capable of picking up their signal over a 150-degree field. As part of this CRADA, Talking Lights will modify their ballast to match the form-factor of ballasts in exit signs. Further, they will release their proprietary encoder design to VA investigators so that the LED Exit Light design can be made fully compatible with the fluorescent light design.

Once developed and optimized, investigators hypothesize a dramatic improvement in egress performance for all ages of two populations:

1. people with severe vision loss who use a white cane or dog for mobility, and
2. people with low vision who do not use a white cane or dog for mobility, yet have problems reading and locating exit signs.

Results will be published and presented for review to the National Fire Prevention Agency (NFPA) for consideration as part of the Life Safety Code, and to the Building Officials and Code Administrators (BOCA) for consideration as part of the National Building Code.

COMPARISONS: Egress using existing emergency exit signage.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Blindness

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Egress Badge Performance

Blind subjects are walked into a building to a specific location, and then are asked to find their way out of the building.

Group Type EXPERIMENTAL

Egress Badge

Intervention Type DEVICE

Egress Badge is worn by subjects who are asked to use the badge to exit the building. The badge indicates the direction of each exit sign on route to an exit.

Baseline Egress Performance

Blind subjects are walked into a building to a particular location and then asked to find their way out of the building.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Egress Badge

Egress Badge is worn by subjects who are asked to use the badge to exit the building. The badge indicates the direction of each exit sign on route to an exit.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Must Be Blind with no better vision than light perception
* Must be able to walk the necessary distances, i.e., three hours of intermittent indoor walking
* OMCT (Orientation-Memory Concentration Test) of 10 or less

Exclusion Criteria

* Patients currently being treated at Atlanta VA Medical Center
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

US Department of Veterans Affairs

FED

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

David A Ross, MSEE Med

Role: PRINCIPAL_INVESTIGATOR

Atlanta VA Medical and Rehab Center, Decatur

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Atlanta VA Medical and Rehab Center, Decatur

Decatur, Georgia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

C3905-R

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Eye Scanning for Safety Driving
NCT06396273 ACTIVE_NOT_RECRUITING
Meta Glasses for Low Vision
NCT07317180 NOT_YET_RECRUITING NA