Long Term Clinical Evaluation of SLS Transtibial Sockets

NCT ID: NCT00167570

Last Updated: 2017-04-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

11 participants

Study Classification

OBSERVATIONAL

Study Start Date

2003-04-30

Study Completion Date

2011-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The overall long-term goal of this project is the development of a clinically practical system for rapid prosthetic limb provision that integrates computer-aided design with solid freeform fabrication techniques. This proposal builds on our previous successful demonstration of the feasibility of SFF socket fabrication and will address several key issues that underlie its clinical viability. The specific objectives of the proposed work are:

1. To develop improved designs for SFF transtibial prosthetic sockets that allow the use of industry standard pylon mounts and incorporate variable compliance elements.
2. Determine the clinical effectiveness of variable wall compliance elements in enhancing the comfort and fit of transtibial prosthetic sockets.
3. Determine the durability and functionality of SFF sockets during extended clinical use.

These objectives will be met over a three-year period. The initial phase of the proposed work will use an iterative engineering design - modeling - evaluation process to develop variable compliance elements and an industry standard pylon mount adapter. During the second phase of the proposed work, clinical evaluations of SFF prosthetic sockets will be studied. The effectiveness of variable compliant elements in enhancing comfort and fit will be determined using a within subject case comparison study of SFF sockets with conventional laminated sockets. Durability of SFF sockets that incorporate an industry standard pylon mounting system will be determined during a 12-month clinical field trial.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Successful rehabilitation for the majority of lower extremity amputees includes prosthetic limb fitting and training. Critical to the success of prosthetic fitting is a comfortable, well fitting socket. Accomplishing this remains a clinical challenge with residual limb pain and socket discomfort affecting 20-55% of lower limb amputees. Achieving an acceptable socket fit using conventional prosthetic techniques requires individual custom molding and fabrication in a labor intensive, costly process. Alternative methods of fabricating prosthetic sockets that can improve efficiency in prosthetic provision, enhance comfort and fit, or reduce cost are needed to ensure the continued optimal rehabilitation of the amputee. This project will continue the development of a new promising method of socket fabrication using solid freeform fabrication (SFF) based on selective laser sintering (SLS) technology. SFF allows the direct manufacture of a prosthetic socket without the intermediate molds and laminating process required with conventional techniques.

The overall long-term goal of this project is the development of a clinically practical system for rapid prosthetic limb provision that integrates computer-aided design with solid freeform fabrication techniques. This proposal builds on our previous successful demonstration of the feasibility of SFF socket fabrication and will address several key issues that underlie its clinical viability. The specific objectives of the proposed work are:

1. To develop improved designs for SFF transtibial prosthetic sockets that allow the use of industry standard pylon mounts and incorporate variable compliance elements.
2. Determine the clinical effectiveness of variable wall compliance elements in enhancing the comfort and fit of transtibial prosthetic sockets.
3. Determine the durability and functionality of SFF sockets during extended clinical use.

These objectives will be met over a three-year period. The initial phase of the proposed work will use an iterative engineering design - modeling - evaluation process to develop variable compliance elements and an industry standard pylon mount adapter. During the second phase of the proposed work, clinical evaluations of SFF prosthetic sockets will be studied. The effectiveness of variable compliant elements in enhancing comfort and fit will be determined using a within subject case comparison study of SFF sockets with conventional laminated sockets. Durability of SFF sockets that incorporate an industry standard pylon mounting system will be determined during a 12-month clinical field trial.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Trauma Diabetes

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Prosthetic socket fabricated using selective laser sintering

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

All subjects will be lower extremity amputees of at least one year duration and are 18 years of age or older.

They must meet the Medicare Functional Classification Level K2 or K3 class for prosthetic use (unlimited household or limited community level ambulator).

Exclusion Criteria

There must be no current stump wounds or breakdown or a history of repeated skin breakdown with adequately fitting prostheses.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

The University of Texas Health Science Center at San Antonio

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Nicolas Walsh, MD

Role: PRINCIPAL_INVESTIGATOR

The University of Texas Health Science Center at San Antonio

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

South Texas Veterans Healthcare System

San Antonio, Texas, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

VA-A2755-r

Identifier Type: -

Identifier Source: secondary_id

VA-A2755-r-UT-001-0011-267

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

3D-Printed Grafts for Knee Cartilage Repair
NCT07312175 ACTIVE_NOT_RECRUITING NA
Perform Humeral System Study
NCT05067543 RECRUITING
SYNOSTE Nitinail System Trial
NCT03752814 TERMINATED NA