Using a Novel Balloon-shaped Large-Focal Pulsed Field Ablation Catheter in Persistent Atrial Fibrillation

NCT ID: NCT07294742

Last Updated: 2025-12-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

34 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-11-06

Study Completion Date

2026-06-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This clinical trial aims to evaluate the safety and effectiveness of pulmonary vein isolation (PVI) and linear ablation using a large-focal pulsed field ablation (PFA) catheter in patients with persistent atrial fibrillation (perAF). The study will address two primary questions:

1. Is the procedure safe, as determined by the absence of serious device- or procedure-related adverse events within 7 days post-ablation?
2. Is the catheter effective in creating durable lesions, as assessed by invasive electrophysiological remapping?

Study Design and Intervention

Eligible patients with perAF underwent PVI and linear ablation under general anesthesia using the PFApple large-focal PFA catheter. The catheter delivers a biphasic, bipolar pulsed electric field (1000V, 0.04 ms pulse duration) to create spherical ablation lesions.

Participant Follow-up Protocol

Enrolled participants will complete the following assessments:

1. Index Procedure: PVI and linear ablation with the PFApple PFA catheter.
2. Durability Assessment: Repeat invasive electrophysiological remapping at 3 months post-ablation to evaluate lesion durability.
3. Clinical Follow-up: Scheduled visits at 7 days, 30 days, 3 months, 6 months, and 12 months post-procedure. Atrial tachyarrhythmia recurrence is assessed via 12-lead electrocardiography at each visit and 24-hour or 7-day Holter monitoring at the 6- and 12-month time points.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Introduction

Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide. Pulmonary vein isolation (PVI) is the established cornerstone therapy for symptomatic, drug-refractory AF. However, for persistent AF (PerAF), the efficacy of PVI alone is reduced compared to its effect in paroxysmal AF. Consequently, adjunctive ablation strategies beyond PVI are often employed in PerAF treatment.

Radiofrequency ablation remains the predominant conventional thermal technique for PerAF. However, its extensive application risks collateral tissue damage and procedure-related complications. These risks present significant challenges to achieving complete, transmural lesions, which may compromise overall ablation efficacy.

Pulsed field ablation (PFA) is an emerging non-thermal technology that induces rapid lesion formation via irreversible electroporation. This modality demonstrates high myocardial selectivity, effectively ablating cardiac tissue while sparing adjacent structures. Preclinical and clinical studies of PFA for PVI report durable lesions and an excellent safety profile, with no evidence of collateral damage. A PVI-plus-additional-ablation (PVI+) strategy is commonly used for PerAF to improve arrhythmia-free survival. However, data on the feasibility and safety of PFA for adjunctive PVI+ ablation remain limited. Whether PFA can enhance the safety and efficacy of PVI+ strategies in PerAF requires further investigation.

This first-in-human study aims to evaluate the feasibility and safety of a novel balloon-shaped, large-focal PFA catheter for PVI+ strategies in patients with PerAF.

Methods

Study Design This was a first-in-human, prospective, single-arm, single-center trial evaluating the safety and efficacy of a novel balloon-shaped, large-focal PFA catheter (PFapple™, EnChannel Medical, Guangdong, China) in patients with PerAF. The study was approved by the local Ethics Committee and conducted in accordance with the Declaration of Helsinki. All participants provided written informed consent.

Study Population Eligible patients were 18-75 years old with documented symptomatic PerAF (AF duration 7-365 days) who were refractory or intolerant to at least one Class I or III antiarrhythmic drug.

Procedural Workflow All procedures were performed under general anesthesia. Following femoral venous access, intravenous heparin was administered to maintain an activated clotting time ≥300 seconds. A decapolar catheter was positioned in the coronary sinus and a ventricular electrode in the right ventricle. Transseptal puncture was performed under fluoroscopic guidance.

An electroanatomic map of the left atrium and pulmonary veins was created using a PENTARAY® catheter and the CARTO 3 system (Biosense Webster). The PFA sheath was inserted and continuously flushed. The PFApple catheter was advanced into the left atrium and navigated to target sites.

PVI was performed in all patients using a wide antral circumferential, point-to-point technique. Typically, 20-30 ablation points were deployed along the PV antrum, maintaining an inter-point distance \<10 mm to ensure lesion continuity and transmurality.

Additional ablation strategies were performed at the operator's discretion. Linear ablation targets included the left atrial posterior wall (LAPW), mitral isthmus (MI), or cavotricuspid isthmus (CTI), with bidirectional block as the endpoint. For MI ablation, if persistent epicardial connections were identified, adjunctive ablation within the coronary sinus was performed.

After a 20-minute waiting period, isolation and block were reassessed. Additional applications were delivered as needed. If AF persisted, electrical cardioversion was performed to restore sinus rhythm. Post-procedure voltage maps were generated to characterize the ablation sets.

Follow-up Post-ablation antiarrhythmic drug use was determined by the operator and typically discontinued after three months. Oral anticoagulation was maintained per guidelines. Structured follow-up occurred at 7 days and 3 months post-ablation, with lesion durability assessed via invasive remapping at 3 months. Additional visits were scheduled at 6 and 12 months. Arrhythmia recurrence was assessed using 12-lead ECGs at each visit and 24-hour or 7-day Holter monitoring at 3, 6, and 12 months.

Endpoints The primary safety endpoint was the incidence of primary adverse events (PAEs) within 7 days post-ablation. Later-occurring events (device/procedure-related death, atrio-esophageal fistula, PV stenosis) were also classified as PAEs. Persistent diaphragmatic paralysis or phrenic nerve palsy at 3 months were considered PAEs.

The primary efficacy endpoint was acute procedural success, defined as the proportion of patients achieving: 1) complete electrical isolation of all PVs, and 2) for those undergoing linear ablation, confirmed bidirectional block at all targeted sites (LAPW, MI, CTI).

Secondary efficacy endpoints included:

1. Acute PV isolation success rate.
2. Acute success rate of bidirectional block for each linear ablation site.
3. Durable success rate of bidirectional block for each linear ablation site at 3-month remapping.
4. One-year freedom from atrial tachyarrhythmia recurrence.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Persistent Atrial Fibrillation

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Persistent Atrial Fibrillation pulse field ablation pulmonary vein isolation posterior wall ablation mitral isthmus tricuspid isthmus

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Ablation group

All patients underwent PVI via point-to-point wide antral circumferential ablation (20-30 points, inter-point distance ≤10 mm) targeting 1-2 mm outside PV ostia (confirmed by angiography/3D mapping) to ensure contiguous, transmural lesions. Operators could optionally add linear ablation (LAPW, MI, CTI, endpoint: bidirectional block). For MI ablation, coronary sinus adjunctive ablation was done for residual epicardial connections if needed. PVI, LAPW isolation, and MI ablation were reassessed 20 minutes later; additional ablation was performed until durable isolation/block. Persistent AF post-ablation was treated with electrical cardioversion. Post-PFA voltage maps were generated to characterize lesions.

Group Type EXPERIMENTAL

a novel Balloon-shaped Large-Focal Pulsed Field Ablation Catheter

Intervention Type DEVICE

All patients underwent PVI via point-to-point wide antral circumferential ablation. Operators could optionally perform linear ablation (LAPW, MI, CTI, endpoint: bidirectional block). For MI ablation, coronary sinus adjunctive ablation was done for residual epicardial connections if needed. PVI, LAPW isolation, and MI ablation were reassessed 20 minutes later; additional ablation was performed until durable isolation/block. Persistent AF post-ablation was treated with electrical cardioversion. Post-PFA voltage maps were generated to characterize lesions.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

a novel Balloon-shaped Large-Focal Pulsed Field Ablation Catheter

All patients underwent PVI via point-to-point wide antral circumferential ablation. Operators could optionally perform linear ablation (LAPW, MI, CTI, endpoint: bidirectional block). For MI ablation, coronary sinus adjunctive ablation was done for residual epicardial connections if needed. PVI, LAPW isolation, and MI ablation were reassessed 20 minutes later; additional ablation was performed until durable isolation/block. Persistent AF post-ablation was treated with electrical cardioversion. Post-PFA voltage maps were generated to characterize lesions.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

18 to 75 years with documented symptomatic PerAF (AF duration: 7 to 365 days), who were either refractory to or intolerant of at least one Class I or III antiarrhythmic drug and willing to provide informed consent.

Exclusion Criteria

1. Paroxysmal atrial fibrillation (AF)
2. AF caused by electrolyte disorders, thyroid diseases, or reversible/non-cardiac etiologies
3. Patients undergoing retreatment after ablation for rapid atrial tachyarrhythmias
4. Patients with sustained ventricular tachycardia or ventricular fibrillation
5. Left atrial anteroposterior diameter \> 55 mm
6. Pulmonary vein (PV) stenosis (\>70%) or prior PV stent implantation
7. History of left atrial ablation or cardiac surgery (including left atrial appendage closure)
8. Implantation of permanent pacemaker, biventricular pacemaker, loop recorder/insertable cardiac monitor (ICM), or any type of implantable cardioverter-defibrillator (with or without biventricular pacing function)
9. Contraindications to anticoagulation, or history of coagulation or bleeding abnormalities
10. Severe pulmonary disease: severe pulmonary arterial hypertension or any pulmonary disease with severe dyspnea involving blood gas abnormalities
11. Any of the following cardiac surgeries, implants, or conditions:

* Prosthetic heart valve
* NYHA Class III or IV congestive heart failure, or left ventricular ejection fraction (LVEF) \< 40%
* Atrial septal defect or ventricular septal defect closure
* Atrial myxoma, left atrial appendage device implantation or occlusion
12. History of any of the following within 3 months prior to the procedure:

* Myocardial infarction
* Unstable angina
* Percutaneous coronary intervention
* Cardiac surgery (including coronary artery bypass grafting)
* Hospitalization for heart failure
* Pericarditis
13. History of any of the following within 3 months prior to the procedure:

* Cerebral infarction or transient ischemic attack (TIA)
* Documented thromboembolic events (e.g., confirmed by transesophageal echocardiography \[TEE\])
14. History of malignant tumor or expected life expectancy \< 12 months
15. Mental disorders or history of mental illness with inability to cooperate independently
16. Lactating, pregnant, or women planning or potentially becoming pregnant
17. Acute or severe systemic infection, or significant abnormalities in liver/renal function
18. Participation in other interventional clinical trials, or ineligibility for enrollment as judged by the investigator
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

The Third People's Hospital of Chengdu

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Hanxiong Liu

Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

The Third People's Hospital of Chengdu

Chengdu, , China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PFApple for PerAF

Identifier Type: -

Identifier Source: org_study_id