A Study at Multiple Centers to Evaluate the Safety and Practicality of the Levita Magnetic Surgical System for Use in Laparoscopic Upper Gastrointestinal Surgeries.

NCT ID: NCT07293611

Last Updated: 2025-12-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2026-01-10

Study Completion Date

2026-09-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

A Study at Multiple Centers to Evaluate the Safety and Practicality of the Levita Magnetic Surgical System for Use in Laparoscopic Upper Gastrointestinal Surgeries.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Upper Gastrointestinal Laparoscopic Surgery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Magnetic Surgical System in laparoscopic upper gastrointestinal procedures

Group Type EXPERIMENTAL

Levita Magnetic Surgical System

Intervention Type DEVICE

The Magnetic Surgical System (MSS), which was cleared for market in the U.S. most recently per 510(k) K252435 and is commercially available in Chile, is composed of two hand-held instruments: a Magnetic Grasper and an external Magnetic Controller.

The Magnetic Grasper is comprised of two main components: a detachable Grasper Tip and a Shaft. The detachable Grasper Tip provided with the Magnetic Grasper is 6.5cm in length. An optional 12.5cm length detachable Grasper Tip may be used as a replacement for the 6.5cm Grasper Tip and can be used with the Shaft interchangeably. The Magnetic Controller is a single unit with handles that is held external to the body and emits a magnetic field that attracts the detachable Grasper Tip.

In this study the 6.5 Grasper Tip will be used.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Levita Magnetic Surgical System

The Magnetic Surgical System (MSS), which was cleared for market in the U.S. most recently per 510(k) K252435 and is commercially available in Chile, is composed of two hand-held instruments: a Magnetic Grasper and an external Magnetic Controller.

The Magnetic Grasper is comprised of two main components: a detachable Grasper Tip and a Shaft. The detachable Grasper Tip provided with the Magnetic Grasper is 6.5cm in length. An optional 12.5cm length detachable Grasper Tip may be used as a replacement for the 6.5cm Grasper Tip and can be used with the Shaft interchangeably. The Magnetic Controller is a single unit with handles that is held external to the body and emits a magnetic field that attracts the detachable Grasper Tip.

In this study the 6.5 Grasper Tip will be used.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* BMI range of 20 to 60kg/m2
* Scheduled to undergo laparoscopic procedures
* Willing and able to provide a written Informed Consent Form (ICF) to participate in the study prior to any study- required procedures

Exclusion Criteria

* Individuals with pacemakers, defibrillators, or other electromedical implants
* Individuals with ferromagnetic implants
* American Society of Anesthesiologists (ASA) score of III or IV
* Significant comorbidities: cardiovascular, neuromuscular, chronic obstructive pulmonary disease, and urological disease (renal failure)
* Clinical history of impaired coagulation confirmed by abnormal blood tests
* Individuals who have signs of hepatic abnormality (e.g.: cirrhosis, liver failure, increase in liver enzymes, etc.)
* Anatomical abnormality or disease of intended target tissue noted after initiation of index procedure that would prevent device use
* Pregnant or wishes to become pregnant during the length of study participation
* Individual is not likely to comply with the follow-up evaluation schedule
* Participating in a clinical trial of another investigational drug or device
* Prisoner or under incarceration
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Levita Magnetics

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Clinica Colonial

Huechuraba, Santiago Metropolitan, Chile

Site Status

Hospital Luis Tisne

Peñalolén, Santiago Metropolitan, Chile

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Chile

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Principal Investigator

Role: primary

Principal Investigator

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

LVT011

Identifier Type: -

Identifier Source: org_study_id