White Noise and Buzzy for Reducing Pain During Infant Vaccination
NCT ID: NCT07286721
Last Updated: 2025-12-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
108 participants
INTERVENTIONAL
2025-09-25
2026-06-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This study is designed as a single-center, randomized controlled, experimental trial aimed at evaluating and comparing the effects of white noise and the Buzzy device on pain experienced by infants during vaccination. The study will be conducted at the Büyükçekmece Central Family Health Center in Istanbul, Türkiye, between October 2025 and October 2026. The target population includes healthy infants aged 0 to 6 months who are scheduled to receive the routine hexavalent vaccine (diphtheria, acellular pertussis, tetanus, inactivated polio, Haemophilus influenzae type B, and hepatitis B).
A total of 108 infants will be included based on a priori power analysis performed using G\*Power software, assuming an alpha level of 0.05, a power of 95%, and an anticipated large effect size. To account for potential dropout or exclusions, 36 infants will be assigned to each of the three study groups: (1) White Noise Group, (2) Buzzy Device Group, and (3) Control Group. Randomization will be conducted by an independent statistician using stratified randomization based on infant age (2, 4, or 6 months) and sex to ensure balanced distribution across groups. The study will use a single-blind design in which the observer assessing pain scores is blinded to group assignment.
In the White Noise Group, infants will listen to white noise beginning approximately 1 to 2 minutes before the vaccination and continuing throughout the procedure. The device will be placed safely within hearing distance of the infant. In the Buzzy Group, the Buzzy device-providing combined vibration and cold stimulation-will be applied approximately 3 cm above the injection site starting 60 seconds before the injection and will remain active until the end of the vaccination. In the Control Group, infants will receive the standard vaccination procedure without additional intervention. All vaccinations will be performed by the same trained nurse to ensure procedural consistency. A parent will remain present for the infant's comfort and to assist in observing behavioral cues.
Pain will be evaluated using the validated FLACC Pain Assessment Scale (Face, Legs, Activity, Cry, Consolability), a widely used behavioral tool suitable for infants and young children. During the vaccination, pain scores will be independently assessed by both a blinded observer (trained research nurse) and the parent. The total FLACC score ranges from 0 (no pain) to 10 (severe pain). Higher scores indicate greater pain. Sociodemographic data for infants and parents will also be collected using a structured introductory information form developed from relevant literature.
Data analysis will be performed using SPSS software. Normality of continuous variables will be assessed using the Kolmogorov-Smirnov test. Depending on the distribution, appropriate parametric or non-parametric tests will be applied. Between-group comparisons for FLACC scores will be conducted using ANOVA or the Kruskal-Wallis test, with post hoc analyses performed where necessary. Descriptive statistics (mean, median, standard deviation, and percentages) will be used to summarize sample characteristics. A significance level of p \< 0.05 will be used for all statistical tests.
The primary objective of this study is to determine whether white noise or the Buzzy device is more effective in reducing pain during infant vaccination compared with standard care. Secondary objectives include comparing the relative effectiveness of the two methods against each other and evaluating factors that may influence pain perception, such as infant age and sex. By generating evidence on the comparative effectiveness of these widely available non-pharmacological interventions, this study aims to support the development of best practices for infant pain management in primary care settings.
The findings may inform clinical guidelines, enhance nurse-led pain management strategies, and contribute to the broader adoption of evidence-based, non-pharmacological methods in pediatric care. If shown to be effective, these techniques may be recommended for routine use during infant vaccinations to improve comfort, reduce distress, and support family-centered care. The study also seeks to raise awareness among healthcare providers and caregivers regarding simple, safe, and practical ways to reduce procedural pain in infants.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
White Noise Group
Infants in this group will listen to white noise beginning approximately 1-2 minutes before the vaccination and continuing throughout the injection procedure. The white noise device will be placed safely within hearing distance of the infant. Pain will be assessed using the FLACC Pain Assessment Scale by a blinded observer and a parent.
Standard Care (in control arm)
White noise will be played 1-2 minutes before vaccination and continued throughout the procedure. The device will be placed within safe hearing distance of the infant. This auditory distraction method is intended to reduce procedural pain. No physical stimulation will be applied.
The Buzzy device will be placed about 3 cm above the injection site 60 seconds before vaccination and kept active until the procedure ends. The device provides vibration and cold stimulation to decrease pain by activating competing sensory pathways.
Infants in the control arm will receive routine vaccination with no additional intervention. No white noise, vibration, or cold stimulation will be used. Pain will be assessed according to standard observation procedures.
Buzzy Device Group
Infants in this group will receive vibration and cold stimulation using the Buzzy device. The device will be placed about 3 cm above the injection site 60 seconds before vaccination and will remain active until the procedure is completed. Pain will be assessed using the FLACC Pain Assessment Scale by a blinded observer and a parent.
Standard Care (in control arm)
White noise will be played 1-2 minutes before vaccination and continued throughout the procedure. The device will be placed within safe hearing distance of the infant. This auditory distraction method is intended to reduce procedural pain. No physical stimulation will be applied.
The Buzzy device will be placed about 3 cm above the injection site 60 seconds before vaccination and kept active until the procedure ends. The device provides vibration and cold stimulation to decrease pain by activating competing sensory pathways.
Infants in the control arm will receive routine vaccination with no additional intervention. No white noise, vibration, or cold stimulation will be used. Pain will be assessed according to standard observation procedures.
Control Group
Infants in this group will receive routine vaccination following standard clinical practice with no additional non-pharmacological intervention. Pain will be assessed using the FLACC Pain Assessment Scale by a blinded observer and a parent.
Standard Care (in control arm)
White noise will be played 1-2 minutes before vaccination and continued throughout the procedure. The device will be placed within safe hearing distance of the infant. This auditory distraction method is intended to reduce procedural pain. No physical stimulation will be applied.
The Buzzy device will be placed about 3 cm above the injection site 60 seconds before vaccination and kept active until the procedure ends. The device provides vibration and cold stimulation to decrease pain by activating competing sensory pathways.
Infants in the control arm will receive routine vaccination with no additional intervention. No white noise, vibration, or cold stimulation will be used. Pain will be assessed according to standard observation procedures.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Standard Care (in control arm)
White noise will be played 1-2 minutes before vaccination and continued throughout the procedure. The device will be placed within safe hearing distance of the infant. This auditory distraction method is intended to reduce procedural pain. No physical stimulation will be applied.
The Buzzy device will be placed about 3 cm above the injection site 60 seconds before vaccination and kept active until the procedure ends. The device provides vibration and cold stimulation to decrease pain by activating competing sensory pathways.
Infants in the control arm will receive routine vaccination with no additional intervention. No white noise, vibration, or cold stimulation will be used. Pain will be assessed according to standard observation procedures.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Receiving routine hexavalent vaccination
* Born at term (≥37 weeks gestation)
* Medically stable at the time of vaccination
Exclusion Criteria
* Use of analgesic, antipyretic, or sedative medications within 24 hours prior to vaccination
* Skin conditions or contraindications at the injection site
* Hearing impairment that may affect response to white noise
* History of adverse reactions to vaccination
* Preterm infants (\<37 weeks gestation)
2 Months
6 Months
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Istanbul Arel University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Burcu SELVI CALSIKAN
Assistant Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Büyükçekmece Central Family Health Center
Istanbul, Istanbul, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2025/21
Identifier Type: -
Identifier Source: org_study_id