Passive Leg Raising in Term Pregnancy on Hemodynamic Monitoring - Validating With Transthoracic ECHO (LG-ECHO)

NCT ID: NCT07253818

Last Updated: 2025-12-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2026-01-01

Study Completion Date

2026-07-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This prospective observational validation study aims to evaluate the agreement and diagnostic accuracy of ClearSight™ compared with transthoracic echocardiography (TTE) during PLR in term pregnant women.

The ultimate goal is to determine whether ClearSight™ can reliably identify preload responsiveness in term pregnant women compared with the echocardiographic gold standard. The clinical implication is that, if validated, ClearSight™ may reduce unnecessary or harmful fluid administration by accurately detecting preload reserve, and improve maternal safety in peripartum care by providing obstetric anesthesiologists with reliable bedside monitoring tools.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Background Pregnancy is characterized by profound hemodynamic changes, which complicate perioperative monitoring and fluid therapy. Non-invasive cardiac output monitoring device, ClearSight™ system, provides continuous stroke volume estimates, but their reliability in pregnant women remains uncertain. Passive leg raising (PLR) is a reversible preload test that can elucidate fluid responsiveness without fluid administration. To date, no study has simultaneously validated ClearSight™ against echocardiographic reference standards during PLR in term pregnant women.

Methods This is a prospective, single-centre, method-comparison and diagnostic accuracy study in term pregnant women (≥37 weeks). Simultaneous ClearSight™ and transthoracic echocardiography (TTE) measurements will be obtained at baseline, during PLR, and during recovery. The primary outcome is agreement between ClearSight™-derived stroke volume index (SVI) changes and TTE-derived Left Ventricular Outflow Tract - Velocity Time Integral (LVOT-VTI) changes during PLR. Secondary outcomes include trending ability and diagnostic accuracy of ClearSight™ Δ%SVI for detecting PLR responders. Four-quadrant and polar plot analyses are the parameters for advanced hemodynamic monitoring methods used in echocardiography to assess fluid responsiveness and cardiac output (CO) trending Sample size: 60 participants, providing at least 180 paired observations.

Conclusions This study will establish whether ClearSight™ can reliably detect preload responsiveness in term pregnant women. Findings could support safer, real-time, non-invasive hemodynamic management during obstetric anaesthesia and maternal critical care.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Maternity Pregnancy Labor and Delivery Hemodynamic Changes

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

hemodynamic changes pregnancy clearsight transthoracic echocardiography Passive Leg Raising Maneuver

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ClearSight™ System

ClearSight™ is FDA 510(k) cleared for non-invasive measurement of blood pressure and derived hemodynamic parameters in adults (≥18 years) and pediatric patients ≥12 years when used with EV1000 or HemoSphere Baseline, during passive leg raising (PLR) and after PLR measurements will be acquired. Data will be continuously recorded for 5 minutes at 60-second intervals using a dedicated monitor (EV1000™).

Intervention Type DEVICE

Transthoracic Echocardiography

This study uses transthoracic echocardiography (TTE), which is a non-invasive imaging modality All measurements will be obtained with participants in the 15° left tilt position in order to minimize inferior vena cava compression from the gravid uterus and to avoid haemodynamic fluctuations associated with positional changes Initially, the left ventricular outflow tract (LVOT) diameter will be obtained at end-expiration in the parasternal long-axis view, measured from the inner edge to inner edge of the aortic annulus. Subsequently, the LVOT velocity-time integral (LVOT-VTI) will be assessed using pulsed-wave Doppler, with the sampling volume positioned at the centre of the LVOT in the apical five-chamber view. LVOT diameter will be measured from the parasternal long-axis view (inner-edge to inner-edge, mid-systole), with the average of two measurements recorded.

Measurements will be recorded at three timepoints: baseline at the end of PLR, after PLR

Intervention Type DEVICE

Passive Leg Raising (PLR) Maneuver

This manoeuvre acts as a rapid, transient, and reversible "auto-fluid challenge" by mobilizing blood from the venous reservoir of the lower extremities into the central circulation. The resulting temporary increase in preload can augment cardiac output in preload-responsive patients through the Frank-Starling mechanism .

An electronically adjustable bed, capable of altering position without requiring active movement from the participant, will be utilized in the study. Baseline hemodynamic recordings will be taken following 5 minutes of rest in supine position with 15° left tilt, and the head of the bed elevated to 45°. Subsequently, the head section of the bed will be swiftly returned to a flat position, while the leg section will be elevated to 45°, thereby achieving passive leg raising. Hemodynamic variables will be measured around 90 seconds after PLR will be compared with baseline values.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Term pregnant patients
* Singleton pregnancy at ≥37+0 weeks of gestation.
* Maternal age between 18 and 45 years.
* Hemodynamically stable and in sinus rhythm.
* Ability to provide verbal and written informed consent.

Exclusion Criteria

* Hypertensive disorders of pregnancy, significant valvular or congenital heart disease, cardiomyopathy, or persistent arrhythmias.
* Multiple gestation (i.e., Twin pregnancy and above)
* Endocrine or hematologic conditions likely to affect hemodynamics, including diabetes with or without autonomic neuropathy, thyroid storm, or severe anemia (hemoglobin \<8 g/dL).
* Active labor with pain or current infusion of uterotonic or vasoactive agents.
* Ruptured membranes with frequent contractions or indications for emergent delivery.
* Inadequate transthoracic echocardiographic imaging windows at screening.
* Emergency or STAT (statim) Cesarean Deliveries
Minimum Eligible Age

18 Years

Maximum Eligible Age

45 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ayse Zeynep Turan Civraz

OTHER_GOV

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ayse Zeynep Turan Civraz

Assoc. Prof. Dr.

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ayten Saracoglu, Prof. MD

Role: PRINCIPAL_INVESTIGATOR

University of Florida

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

UF Health Jacksonville (Shands Hospital)

Jacksonville, Florida, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ayten Saracoglu, Prof. MD

Role: CONTACT

Phone: +1 904 524-5932

Email: [email protected]

Kemal T Saracoglu, Prof. MD

Role: CONTACT

Phone: +1(904) 524 5932

Email: [email protected]

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Ayten Saracoglu, Prof. MD

Role: primary

References

Explore related publications, articles, or registry entries linked to this study.

Vartun A, Flo K, Acharya G. Effect of passive leg raising on systemic hemodynamics of pregnant women: a dynamic assessment of maternal cardiovascular function at 22-24 weeks of gestation. PLoS One. 2014 Apr 14;9(4):e94629. doi: 10.1371/journal.pone.0094629. eCollection 2014.

Reference Type BACKGROUND
PMID: 24732308 (View on PubMed)

Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA; Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr. 2002 Feb;15(2):167-84. doi: 10.1067/mje.2002.120202. No abstract available.

Reference Type BACKGROUND
PMID: 11836492 (View on PubMed)

Duclos G, Granier S, Hili A, Blanc J, Einav S, Leone M, Zieleskiewicz L. Performance of non-invasive stroke volume variation during passive leg raising as a predictor of hypotension following induction of spinal anesthesia for elective cesarean delivery: a single cohort study. Int J Obstet Anesth. 2022 May;50:103251. doi: 10.1016/j.ijoa.2021.103251. Epub 2021 Dec 30.

Reference Type BACKGROUND
PMID: 35074676 (View on PubMed)

Duclos G, Hili A, Resseguier N, Kelway C, Haddam M, Bourgoin A, Carcopino X, Zieleskiewicz L, Leone M. Clearsight use for haemodynamic monitoring during the third trimester of pregnancy - a validation study. Int J Obstet Anesth. 2018 Nov;36:85-95. doi: 10.1016/j.ijoa.2018.04.009. Epub 2018 May 8.

Reference Type BACKGROUND
PMID: 30392653 (View on PubMed)

Marques NR, Martinello C, Kramer GC, Costantine MM, Vadhera RB, Saade GR, Hankins GD, Pacheco LD. Passive leg raising during pregnancy. Am J Perinatol. 2015 Mar;32(4):393-8. doi: 10.1055/s-0034-1389089. Epub 2014 Sep 21.

Reference Type BACKGROUND
PMID: 25241109 (View on PubMed)

Herrera S, Kuhlmann-Capek MJ, Rogan SC, Saad AF, Saade GR, Hankins GDV, Pacheco LD. Stroke Volume Recruitability during the Third Trimester of Pregnancy. Am J Perinatol. 2018 Jul;35(8):737-740. doi: 10.1055/s-0037-1615788. Epub 2017 Dec 26.

Reference Type BACKGROUND
PMID: 29278864 (View on PubMed)

Vartun A, Flo K, Wilsgaard T, Acharya G. Maternal functional hemodynamics in the second half of pregnancy: a longitudinal study. PLoS One. 2015 Aug 10;10(8):e0135300. doi: 10.1371/journal.pone.0135300. eCollection 2015.

Reference Type BACKGROUND
PMID: 26258418 (View on PubMed)

Monnet X, Teboul JL. Prediction of fluid responsiveness in spontaneously breathing patients. Ann Transl Med. 2020 Jun;8(12):790. doi: 10.21037/atm-2020-hdm-18.

Reference Type BACKGROUND
PMID: 32647715 (View on PubMed)

Helmer P, Helf D, Sammeth M, Winkler B, Hottenrott S, Meybohm P, Kranke P. The Use of Non-Invasive Continuous Blood Pressure Measuring (ClearSight(R)) during Central Neuraxial Anaesthesia for Caesarean Section-A Retrospective Validation Study. J Clin Med. 2022 Aug 2;11(15):4498. doi: 10.3390/jcm11154498.

Reference Type BACKGROUND
PMID: 35956113 (View on PubMed)

Akkermans J, Diepeveen M, Ganzevoort W, van Montfrans GA, Westerhof BE, Wolf H. Continuous non-invasive blood pressure monitoring, a validation study of Nexfin in a pregnant population. Hypertens Pregnancy. 2009 May;28(2):230-42. doi: 10.1080/10641950802601260.

Reference Type BACKGROUND
PMID: 19437233 (View on PubMed)

Lihme F, Basit S, Persson LG, Larsen MO, Lauridsen KH, Lykke JA, Andersen AS, Halse K, Thorsen-Meyer A, Melbye M, Wohlfahrt J, Boyd HA. Reference ranges for third-trimester maternal cardiovascular function parameters measured in normotensive pregnant women using a non-invasive cardiac output monitor: A study based on data from the prospective PEACH cohort study. BJOG. 2024 Mar;131(4):463-471. doi: 10.1111/1471-0528.17667. Epub 2023 Sep 21.

Reference Type BACKGROUND
PMID: 37735094 (View on PubMed)

McLaughlin K, Wright SP, Kingdom JCP, Parker JD. Clinical Validation of Non-Invasive Cardiac Output Monitoring in Healthy Pregnant Women. J Obstet Gynaecol Can. 2017 Nov;39(11):1008-1014. doi: 10.1016/j.jogc.2017.02.015. Epub 2017 Jul 18.

Reference Type BACKGROUND
PMID: 28733057 (View on PubMed)

Ling HZ, Gallardo-Arozena M, Company-Calabuig AM, Nicolaides KH, Kametas NA. Clinical validation of bioreactance for the measurement of cardiac output in pregnancy. Anaesthesia. 2020 Oct;75(10):1307-1313. doi: 10.1111/anae.15110. Epub 2020 May 29.

Reference Type BACKGROUND
PMID: 32469423 (View on PubMed)

Kinsella SM, Carvalho B, Dyer RA, Fernando R, McDonnell N, Mercier FJ, Palanisamy A, Sia ATH, Van de Velde M, Vercueil A; Consensus Statement Collaborators. International consensus statement on the management of hypotension with vasopressors during caesarean section under spinal anaesthesia. Anaesthesia. 2018 Jan;73(1):71-92. doi: 10.1111/anae.14080. Epub 2017 Nov 1. No abstract available.

Reference Type BACKGROUND
PMID: 29090733 (View on PubMed)

Cornette J, Laker S, Jeffery B, Lombaard H, Alberts A, Rizopoulos D, Roos-Hesselink JW, Pattinson RC. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review. Ultrasound Obstet Gynecol. 2017 Jan;49(1):25-31. doi: 10.1002/uog.16015. Epub 2016 Nov 28.

Reference Type BACKGROUND
PMID: 27404397 (View on PubMed)

Bijl RC, Valensise H, Novelli GP, Vasapollo B, Wilkinson I, Thilaganathan B, Stohr EJ, Lees C, van der Marel CD, Cornette JMJ; International Working Group on Maternal Hemodynamics. Methods and considerations concerning cardiac output measurement in pregnant women: recommendations of the International Working Group on Maternal Hemodynamics. Ultrasound Obstet Gynecol. 2019 Jul;54(1):35-50. doi: 10.1002/uog.20231.

Reference Type BACKGROUND
PMID: 30737852 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

AS-01-OBS

Identifier Type: -

Identifier Source: org_study_id