Duke Customized Aortic Aneurysm Repair With Endovascular Stent-grafts - Duke CARES Trial

NCT ID: NCT07064460

Last Updated: 2025-12-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2026-01-02

Study Completion Date

2031-12-11

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to see if physician modified endovascular grafts (PMEG) can be used safely for the treatment of aortic disorders. The surgeon will modify a commercially available graft tailored to the participant's anatomy for surgery. The researchers will follow participants for 5 years, which will require regular visits to the clinic for follow-up imaging and follow-up blood tests.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The primary objective of the clinical investigation Duke CARES Trial is to assess the use of physician-modification of commercially available, off-the-shelf, endovascular stent-grafts to treat juxtarenal, pararenal and paravisceral complex abdominal aneurysms or thoracoabdominal aneurysms in high-risk for open surgery subjects having appropriate anatomy. The primary intent of the study is to assess safety and efficacy of the device acutely (i.e., treatment success and technical success), at 30 days (i.e., the rate of major adverse events (MAE)) and at 6 months, 12 months and annually to 5 years (i.e., the proportion of treatment group subjects that achieve and maintain treatment success).

Additionally, the study will assess domains for improvement of patient selection criteria, device design, operative techniques, and follow-up regimens to benefit patients undergoing complex endovascular aneurysm repair

Main Study - Statistical Cohort Physician Modified Endovascular Grafts are indicated for endovascular repair of juxtarenal, pararenal, paravisceral and thoracoabdominal aneurysms, in high-risk for open surgery subjects having appropriate anatomy as defined in the eligibility section.

Non-statistical cohort Patients with life-threatening aortic disease who have no acceptable surgical or endovascular alternatives will be allowed to receive treatment under this IDE. Enrollment of these patients under the IDE permits systematic data collection and FDA oversight, while their separation from the primary study cohort preserves the integrity of the safety and effectiveness analyses. This approach provides a treatment option for critically ill patients by offering access to a potential therapeutic option within a regulated and monitored environment without compromising the scientific validity of the trial. The patients in this cohort will follow standard of care, which includes follow-up at 1 month, 6 months and then annually. Data collection and presentation in this cohort will be consistent with the primary study cohort; however, data from this cohort will not be included in the statistical analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Disorders

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

aortic disorders endovascular grafts

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Physician Modified Endovascular Graft

The participant's surgeon will modify a commercially available graft tailored to their anatomy for their surgery.

Group Type EXPERIMENTAL

Physician Modified Endovascular Graft

Intervention Type DEVICE

The participant's surgeon will modify a commercially available graft tailored to their anatomy for their surgery. All components used to create the final device (PMEG), made specifically for each participant and tailored to their individual anatomy, are FDA-approved, although the final graft itself (the PMEG) is considered investigational.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Physician Modified Endovascular Graft

The participant's surgeon will modify a commercially available graft tailored to their anatomy for their surgery. All components used to create the final device (PMEG), made specifically for each participant and tailored to their individual anatomy, are FDA-approved, although the final graft itself (the PMEG) is considered investigational.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* A participant may be entered into the study if the participant has at least one of the following: An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e, perpendicular to the centerline) measurements; Aneurysm with a history of growth \> 0.5 cm in 6 months; Saccular aneurysm deemed at significant risk for rupture; Symptomatic aneurysm; Ruptured aneurysm

AND

* Extent of aorta to be treated: juxtarenal, pararenal that include 1 or 2 renal and/or accessory renal arteries, paravisceral that includes celiac artery and/or superior mesenteric artery, and/or thoracoabdominal
* High risk of morbidity and mortality with open surgical repair as defined by:

a. Anatomic Criteria (Previous abdominal surgery; Previous thoracotomy; Previous aortic surgery) b. Physiologic Criteria (ASA Category III or higher; Age \>70 years; Previous myocardial infarction, coronary artery disease, or coronary artery stent; Coronary stress test with a reversible perfusion defect; Congestive heart failure (CHF); Chronic obstructive pulmonary disease (COPD))
* Iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Nonaneurysmal aortic segment proximal to the aneurysm (neck) with a minimum neck length of 25 mm (Diameter in the range of 18 mm - 42 mm; Angle less than 60o relative to the axis of the aneurysm; Angle less than 60o relative to the axis of the suprarenal aorta);

* Minimum branch vessel diameter greater than 5 mm
* Iliac artery distal fixation site greater than 20 mm in length and diameter in the range of 9 mm - 21 mm (for use of ZFEN)
* Contralateral iliac artery distal fixation site greater than 20 mm in length and diameter in the range of 7.5 mm - 20 mm.
* Age: ≥ 18 years old
* Life expectancy: \> 2 years


* Able to be treated in accordance with the instructions for use with a currently marketed endovascular prosthesis
* Subject prefers to receive treatment at another hospital with access to a custom-made endovascular prosthesis
* Refusal to give informed consent by the subject or legal representative. Note: Inability to consent prior to surgery will not be exclusionary if it is for life-saving measures.
* Known sensitivities or allergies to the materials of construction of the devices will be allowed in a life-threatening situation where the patient would not survive open surgery.

Exclusion Criteria

* Able to be treated in accordance with the instructions for use with a currently marketed endovascular prosthesis
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent by subject or legal representative
* Pregnant or breastfeeding
* Prefers to receive treatment at another hospital with access to a non-physician modified endovascular prosthesis
* Refusal of blood transfusions for religious or personal reasons
* Participation in another investigational clinical or device trial, with the exception of another investigational endovascular stent-graft protocol or percutaneous aortic valve protocol, not encompassed by the IDE protocol and performed remotely from the fenestrated procedure (\> 30 days). Examples include remote (\>30 days) participation in a thoracic, abdominal or iliac branch device trial, or participation in a percutaneous aortic valve trial.
* Mycotic aneurysm or evidence of active systemic infection


* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (nickel, titanium), polyester, polypropylene, gold, stainless steel, and/or solder (tin, silver).
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment

• Morbid obesity (BMI ≥ 40 or BMI 30-39.9 with comorbidities)
* Major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Baseline creatinine greater than 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
* Deemed a high risk due to significant comorbidities, adjudicated by severity according to the Society for Vascular Surgery reporting standards for endovascular aortic repair involving the renal-mesenteric arteries


* Thrombus or excessive calcification within the neck of the aneurysm
* Presence of significant thrombus and/or excessive calcification within the intended proximal or distal seal zone of the aneurysm.
* Branch stenosis \> 75% (if left untreated)
* Anatomy that would not allow maintenance of at least one patent hypogastric artery

* Inadequate femoral or iliac access to accommodate the required delivery systems.
* Requirement for iliac conduit in cases of inadequate femoral/iliac access
* Absence of a suitable non-aneurysmal segment of distal thoracic aorta and significant aortic tortuosity.
* Target vessel anatomy not compatible with fenestrated or branched stent graft incorporation, including vessels with severe stenosis, tortuosity and/or insufficient size to accommodate stent graft placement.
* Early target vessel bifurcation precluding safe or effective stent graft placement.
* Unsuitable iliac artery fixation site and/or anatomy for iliac limb extension or iliac branch device placement, as defined by the device instructions for use

Note: Patients with life-threatening aortic disease who have no acceptable surgical or endovascular alternatives will be allowed to receive treatment under this IDE in the non-statistical cohort

Non-statistical Cohort
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chandler Long, MD

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Chandler Long, MD

Associate Professor of Surgery

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Chandler Long, MD

Role: PRINCIPAL_INVESTIGATOR

Duke University

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ellen R Burkett, MSHS

Role: CONTACT

Phone: 9196811878

Email: [email protected]

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Pro00116274

Identifier Type: -

Identifier Source: org_study_id