Towards a More Standardized Bicuspid Aortic Valve Repair: Rationale and Design of CONTOUR Trial - a Randomized Trial
NCT ID: NCT06869954
Last Updated: 2025-10-07
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
100 participants
INTERVENTIONAL
2025-05-21
2027-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods: CONTOUR is a multicenter, randomized controlled trial designed to enroll 100 consecutive BAV patients with AR across four sites in Germany. BAV AR patients with an asymmetric configuration and without concomitant root aneurysm will be randomized 1:1 to undergo aortic valve repair using an internal HAART 200 annuloplasty device (i.e., INTERNAL group) (n=50) or external annuloplasty (i.e., double external ring annuloplasty) in the EXTERNAL group (n=50). 4D flow MRI will be performed preoperatively (t1), postoperatively at discharge (t2), and at 1-year follow-up (t3) for rater-blinded assessment of hemodynamic profiles (i.e., flow eccentricity) and regurgitation fraction at the MRI core-lab. Two hierarchically ordered primary endpoints will be considered: (1) postoperative reduction of flow eccentricity at hospital discharge and (2) regurgitation fraction (%) at 1-year follow-up.
Discussion: The CONTOUR trial is designed to test the hypothesis that an internal annuloplasty device, creating a completely symmetric post-repair BAV geometry, achieves superior aortic valve repair outcomes compared to external annuloplasty. If our hypothesis is confirmed, our study will significantly influence aortic valve repair practice and contribute to the refinement of guideline recommendations in the management of BAV patients with AR.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
HAART 200 Aortic Valve Annuloplasty Trial
NCT02071849
HAART Model 300 Annuloplasty Ring
NCT01400841
HAART Annuloplasty Device Valve Repair Registry
NCT04035356
Contour 3D®/TriAd® Tricuspid Annuloplasty Ring Post-Market Clinical Trial
NCT01585779
The preDIlatation in tRanscathEter aortiC Valve implanTation Trial
NCT02448927
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
INTERNAL Group
For the INTERNAL group, the HAART 200 internal annuloplasty ring (CorCym, London, UK), specifically designed for BAV morphology, will be used for all patients. Intraoperative sizing for the internal ring is based on the geometric orientation and size of the non-fused cusp. A standard ball sizer is used for the measurement of the non-fused cusp to assess commissural orientation and surface area of the non-fused cusp. Sizing typically results in values of 23mm or 25mm, with other sizes being very rare. Both commissural posts of the internal annuloplasty ring are fixed using two subcommissural sutures \[10\]. A modified technique for placement of transannular looping sutures will be used to secure the internal ring in the subannular position, as recently published \[21\]. Cusp maneuvers (i.e., shaving, thinning of the raphe, central plication sutures) will be performed to achieve an effective height of 8-10 mm. When indicated (i.e., for ascending aortic diameter \> 45mm or aiming to achieve t
Internal HAART 200 annuloplasty device
For the INTERNAL group, the HAART 200 internal annuloplasty ring (CorCym, London, UK), specifically designed for BAV morphology, will be used for all patients. Intraoperative sizing for the internal ring is based on the geometric orientation and size of the non-fused cusp. A standard ball sizer is used for the measurement of the non-fused cusp to assess commissural orientation and surface area of the non-fused cusp. Sizing typically results in values of 23mm or 25mm, with other sizes being very rare. Both commissural posts of the internal annuloplasty ring are fixed using two subcommissural sutures \[10\]. A modified technique for placement of transannular looping sutures will be used to secure the internal ring in the subannular position, as recently published \[21\]. Cusp maneuvers (i.e., shaving, thinning of the raphe, central plication sutures) will be performed to achieve an effective height of 8-10 mm. When indicated (i.e., for ascending aortic diameter \> 45mm or aiming to achieve th
EXTERNAL group
For the EXTERNAL group, all study patients will undergo double external Dacron ring annuloplasty by simultaneous stabilization of the basal virtual ring and the STJ \[22\]. The surgical technique of double external annuloplasty, detailed by the Lansac group \[22\], involves aortic annulus sizing with a Hegar dilator to select the sizes of the external subannular annuloplasty ring and STJ ring (same size). After deep dissection of the aortic root, 6-7 2-0 pledgeted U sutures are placed circumferentially at the level of the virtual basal ring for external subannular ring implantation. Cusp maneuvers are performed similar to those in the INTERNAL group. STJ stabilization is achieved using an external STJ ring or ascending aortic replacement with a vascular tube graft (e.g., in cases with a high offspring of the right coronary artery). Treatment of the tubular ascending aorta is identical to the INTERNAL group.
double external ring annuloplasty
For the EXTERNAL group, all study patients will undergo double external Dacron ring annuloplasty by simultaneous stabilization of the basal virtual ring and the STJ \[22\]. The surgical technique of double external annuloplasty, detailed by the Lansac group \[22\], involves aortic annulus sizing with a Hegar dilator to select the sizes of the external subannular annuloplasty ring and STJ ring (same size). After deep dissection of the aortic root, 6-7 2-0 pledgeted U sutures are placed circumferentially at the level of the virtual basal ring for external subannular ring implantation. Cusp maneuvers are performed similar to those in the INTERNAL group. STJ stabilization is achieved using an external STJ ring or ascending aortic replacement with a vascular tube graft (e.g., in cases with a high offspring of the right coronary artery). Treatment of the tubular ascending aorta is identical to the INTERNAL group.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Internal HAART 200 annuloplasty device
For the INTERNAL group, the HAART 200 internal annuloplasty ring (CorCym, London, UK), specifically designed for BAV morphology, will be used for all patients. Intraoperative sizing for the internal ring is based on the geometric orientation and size of the non-fused cusp. A standard ball sizer is used for the measurement of the non-fused cusp to assess commissural orientation and surface area of the non-fused cusp. Sizing typically results in values of 23mm or 25mm, with other sizes being very rare. Both commissural posts of the internal annuloplasty ring are fixed using two subcommissural sutures \[10\]. A modified technique for placement of transannular looping sutures will be used to secure the internal ring in the subannular position, as recently published \[21\]. Cusp maneuvers (i.e., shaving, thinning of the raphe, central plication sutures) will be performed to achieve an effective height of 8-10 mm. When indicated (i.e., for ascending aortic diameter \> 45mm or aiming to achieve th
double external ring annuloplasty
For the EXTERNAL group, all study patients will undergo double external Dacron ring annuloplasty by simultaneous stabilization of the basal virtual ring and the STJ \[22\]. The surgical technique of double external annuloplasty, detailed by the Lansac group \[22\], involves aortic annulus sizing with a Hegar dilator to select the sizes of the external subannular annuloplasty ring and STJ ring (same size). After deep dissection of the aortic root, 6-7 2-0 pledgeted U sutures are placed circumferentially at the level of the virtual basal ring for external subannular ring implantation. Cusp maneuvers are performed similar to those in the INTERNAL group. STJ stabilization is achieved using an external STJ ring or ascending aortic replacement with a vascular tube graft (e.g., in cases with a high offspring of the right coronary artery). Treatment of the tubular ascending aorta is identical to the INTERNAL group.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Severe aortic regurgitation (vena contracta (vc) \> 6mm and/or pressure half-time (PHT) \< 200 ms and/or effective regurgitant orifice area (EROA) \> 30 mm2 and/or regurgitant volume (RV) \> 60 ml/beat and/or left ventricular end-systolic diameter (LVESD) \> 50mm (or indexed LVESD \> 20mm/m2 BSA) and/or regurgitation fraction (RF) in cardiothoracic MRI \> 40%) (at least one parameter is required) \[15\]
3. Isolated aortic valve surgery or concomitant procedure (including CABG and/or mitral/tricuspid valve surgery and/or ascending aortic surgery)
4. Willingness to participate and written informed consent
5. Age at surgery \> 18 years
Exclusion Criteria
2. Moderate/severe BAV cusp calcifications extending beyond the raphe region and/or necessitating patch implantation (deemed irreparable based on preoperative TOE (as by decision of the operating surgeon)
3. Concomitant aortic root aneurysm \> 45mm requiring simultaneous aortic root surgery \[16\]
4. Acute/subacute BAV endocarditis
5. Contraindication to MRI
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universitätsklinikum Hamburg-Eppendorf
OTHER
University Clinic Frankfurt
OTHER
Heart Center Leipzig - University Hospital
OTHER
University Hospital Augsburg
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Augsburg
Augsburg, Bavaria, Germany
University Heart and Vascular Center Frankfurt
Frankfurt am Main, Hesse, Germany
Heart Center Leipzig
Leipzig, Saxony, Germany
Medical Center Hamburg-Eppendorf
Hamburg, , Germany
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Thomas Walther, Prof.
Role: primary
Michael Borger, Prof.
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Girdauskas E, Stock S, Hofbauer D, Petersen J, Reichenspurner H, Holubec T, Walther T, Vogl T, Borger M, Gutberlet M, Kroncke T, Decker J, Zapf A, Lezius S, Lenz A, Lansac E, Bannas P. Towards a more standardized bicuspid aortic valve repair: rationale and design of the CONTOUR trial. Eur J Cardiothorac Surg. 2025 Oct 22:ezaf360. doi: 10.1093/ejcts/ezaf360. Online ahead of print.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
23-0625
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.