Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
15 participants
INTERVENTIONAL
2025-11-06
2031-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The Cytex device offers an alternative treatment option for this patient population - those suffering from hip osteoarthritis (OA), unresponsive to conservative care, yet considered too young or active for total joint replacement. Notably, the Cytex implant preserves all pre-existing healthy bone stock, unlike traditional total hip resurfacing or arthroplasty procedures, allowing for future revision to conventional resurfacing or arthroplasty if needed.
The investigational device for this study, the ReNew Hip Implant, is a bioabsorbable, highly porous implant designed with mechanical properties that closely mimic those of healthy articular cartilage. The implant features a bicomponent structure, combining a biomimetic 3D woven textile with a porous 3D-printed framework.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Investigational Arm
The investigation device for this study will be the ReNew Hip Implant.
ReNew Hip Implant
Surgical Intervention
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ReNew Hip Implant
Surgical Intervention
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. BMI \< 35
3. Failed at least 6 weeks of conservative treatment (e.g., anti-inflammatory pain medications, physical therapy, injections)
4. Duration of symptoms consistent with intra-articular disease (i.e., groin, lateral and/or posterior hip pain) that have persisted for at least 3 months)
5. Loss of articular cartilage integrity (\~1 - 6 cm\^2 in area) on the femoral head (confirmed by MRI), without an opposing lesion, that can be treated with a single ReNew Hip Implant
6. Radiographic assessment with joint space width \> 2 mm (verified by x-ray)
7. Meets an acceptable preoperative medical clearance and is free of conditions that would pose excessive operative risk, in the opinion of the investigator
8. Given consent to participate in the study
9. Able to understand the purpose of the study, his/her role, and is available for follow-up for the duration of the study:
1. Subject has signed an IRB (Institutional Review Board) approved Informed Consent Form agreeing to participate in the extension study after the nature, scope, and possible consequences of the study have been explained in an understandable form
2. Subject is able to fully understand the purpose of the study, his/her role as a participant in the study, and plans to be available through five years post-operative follow-up
Exclusion Criteria
2. Type 1 or Type 2 Diabetes
3. Systemic steroid use in the 3 months prior to screening
4. Coxa plana, coxa magna, or proximal femoral focal deficiency on the femoral head that would result in implant mismatch of the femoral head contour
5. Any acute or chronic condition that would limit the ability of the patient to participate in the study (e.g., COPD, congestive heart failure),
6. Bleeding disorders
7. Current cancer (with the exception of non-melanoma skin cancer)
8. Pregnancy or planning to become pregnant during the study period
9. Active infection or sepsis
10. History of local hip infection
11. Known metastatic or neoplastic disease
12. Conditions that may interfere with implant survival or outcomes (e.g., severe dysplasia)
13. Life expectancy less than 2 years
14. Intra-articular therapy within 3 months of enrollment
15. Inadequate bone stock (as determined by SCORE or MORES assessment) to support the device
16. Femoral head is:
1. outside of the 46 - 56 mm range in either anteroposterior diameter or lateral diameters or
2. an aspherical head deformity that results in contour mismatch of 16a
17. Moderate to severe renal insufficiency
18. Emotional or neurological condition that would preempt ability or willingness to participate in the study
19. Above the knee amputation of the contralateral or ipsilateral leg
20. Known allergies to the components of the device (polycaprolactone)
21. Is a prisoner
14 Years
64 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
MCRA
INDUSTRY
Cytex Therapeutics, Inc.
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Washington University School of Medicine
St Louis, Missouri, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Zak Robben
Role: primary
Caroline Drain
Role: backup
References
Explore related publications, articles, or registry entries linked to this study.
Roemer FW, Hunter DJ, Winterstein A, Li L, Kim YJ, Cibere J, Mamisch TC, Guermazi A. Hip Osteoarthritis MRI Scoring System (HOAMS): reliability and associations with radiographic and clinical findings. Osteoarthritis Cartilage. 2011 Aug;19(8):946-62. doi: 10.1016/j.joca.2011.04.003. Epub 2011 Apr 20.
Gold SL, Burge AJ, Potter HG. MRI of hip cartilage: joint morphology, structure, and composition. Clin Orthop Relat Res. 2012 Dec;470(12):3321-31. doi: 10.1007/s11999-012-2403-7.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CIP-0001
Identifier Type: -