Reliability of a Portable Audiometric Device Based on Active Noise-Canceling Headphones for Clinical Hearing Assessment
NCT ID: NCT06811610
Last Updated: 2025-02-06
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
120 participants
OBSERVATIONAL
2024-03-29
2026-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Part Two: Research Objectives To verify the reliability of a novel portable hearing testing device in assessing hearing conditions.
Part Three: Research Design Paired design
Part Four: Inclusion and Exclusion Criteria
Inclusion Criteria:
Age: ≥6 years old, no gender restriction Able to cooperate in completing pure tone audiometry
Exclusion Criteria:
Patients with acute otitis media or unremovable secretions blocking the external auditory canal Patients with mental or psychological disorders or unable to cooperate with the examination for other reasons
Part Five: Research Process This study will recruit volunteers from the outpatient and inpatient departments of Xijing Hospital. Each volunteer will undergo two audiological tests, with at least a 10-minute interval between the two tests to prevent intolerance to the hearing tests. Each audiological test will take approximately 6-8 minutes per subject.
Consultation and Physical Examination:
Researchers will collect general information, including name, gender, age, hearing status, and ear disease history; Conduct a physical examination of the ears; If a volunteer meets the inclusion criteria and voluntarily sign the informed consent form, researchers will determine the testing order using a random number method based on your enrollment sequence.
Conventional pure-tone audiometry:Patients undergo conventional pure tone audiometry using the interacoustics AC40 (Denmark) with TDH39 headphones (Telephonics; Farmingdale, NY, USA). We conducte audiometric testing in a sound-proof booth (background noise\<30dBA) and evaluate the frequency range of 125-8000 Hz. Before the audiometry, patients will be asked to identify which ear have better hearing, and the ear with better hearing was tested first. This study employ the Hughson-Westlake approach, known as the " up-5 down-10 technique." The pure tone sound level was initially introduced at an estimated higher threshold and reduced by 10 dB HL after a correct response from the patient. If the patient did not respond correctly or at all, the sound level was increased by 5 dB HL. When there was a difference of 40 dB HL or more in air conduction thresholds between the ears, contralateral masking was applied to correct the cross-hearing.
E200 Audiometry: Noise-canceling headphones (RAN-3500) are used for all patients during the E200 audiometry. This is conducted in a regular room (ambient noise: 42.6-58.7 dBA, measured using a standard sound level meter: AWA6292 Multi-function Sound Level Meter) adjacent to a busy hallway without a sound-proof booth to simulate an ordinary environment. The Hughson-Westlake approach and contralateral masking are applied when conducting the E200 audiometry.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
NCT05533840
Longitudinal Outcomes of Hearing Aids
NCT04030299
Normal Values in Hearing and Balance Testing
NCT01629108
Hearing Aids Use in Elderly: Efficacy in Speech Perception and in Health-related Quality of Life
NCT04333043
Early Detection of Noise-Induced Hearing Loss
NCT01022710
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Randomization: The sequence in which the patient undergoes the hearing tests is randomly determined using a random number table, ensuring an interval of at least 10 min between the two tests to avoid errors caused by fatigue or discomfort from consecutive testing.
Two individuals were responsible for entering the data, after which they verified each other's entries for accuracy.
Risks and Discomforts:
This study is a paired study utilizing a crossover trial method. All participants will undergo non-invasive procedures including basic information collection, medical history inquiry, physical examination, and pure tone audiometry. Pure tone audiometry, a standard outpatient clinical test, is conducted in a soundproof room. While this is a commonly used clinical examination method, an extremely small number of subjects may experience discomfort such as nervousness and anxiety due to不适应 to the enclosed environment. These symptoms can quickly subside once the subject leaves the environment and generally do not require special treatment. During the hearing test, pure tones are used. A minority of subjects with acoustic sensitivity may experience intolerance, ear pain, or other discomfort when exposed to louder sound stimuli. To mitigate this, the sound is gradually increased from a low volume during the examination. The researcher will closely monitor the subject's reactions, and if discomfort arises, the examination will be immediately halted. In most cases, symptoms will spontaneously resolve without special treatment after the examination is stopped. This study does not pose any additional risks to participants. For any adverse reactions that occur during the study, the researcher must accurately record them, promptly handle them according to medical protocols, and increase the frequency of follow-up visits or conduct additional laboratory tests based on the subject's condition. Follow-up should continue until the issue is properly resolved, the subject's condition stabilizes or returns to normal, or the researcher deems it appropriate to terminate follow-up.
Personal Information Confidentiality:
The information collected in this study will be kept confidential within the hospital as confidential material. To protect the identity of the subjects, any information related to the subjects in the research documents will be identified using a uniformly formatted number rather than names. Among all the collected and combined information of the subjects, any information that could help identify you will be removed to ensure that the relevant information cannot be linked to a specific research subject.
Sample Size Calculation: Based on the 69 data groups obtained in the pre-experiment, the Kappa coefficients were calculated as follows: left ear: 0.764, right ear: 0.743. A confidence level of 0.9 (α= 0.1) was used, and the confidence interval width was set to 0.2. The sample sizes computed using the PASS 2021 were determined to be 89 for the left ear and 107 for the right ear (eFigure 2 in Supplement 1). Ultimately, 114 patients were enrolled to validate the reliability of the E200.
Ethics: All patients provided written informed consent, and the study was approved by the Medical Ethics Committee of the First Affiliated Hospital of the Air Force Medical University(Ethics Committee FILE No: KY20242145-F-1). This study was conducted in accordance with the Declaration of Helsinki and Good Clinical Practice guidelines .
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Participants were tested for hearing using a new type of hearing detection device
Participants' hearing was tested using a portable audiometry device (E200) based on active noise-cancelling headphones, manufactured by Wuhan Doulisten Technology Co., LTD
Participants' hearing was tested using a new portable pure tone audiometry device
Participants' hearing was tested using a portable audiometry device (E200) based on active noise-cancelling headphones, manufactured by Wuhan Doulisten Technology Co., LTD
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Must be able to cooperate in completing pure tone audiometry
Exclusion Criteria
* Those suffering from mental illness or other reasons unable to cooperate with the completion of the examination Remarks: Each participant was examined by a specialist using otoscope. Those with ceruminous external auditory canal embolism or secretion blockage were cleared before audiological examination
6 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Wuhan Douting Technology Co., Ltd
UNKNOWN
Xijing Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
dingjun zha, Doctor of Medicine
Role: STUDY_DIRECTOR
Department of Otolaryngology, the First Affiliated Hospital of Air Force Medical University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
The First Affiliated Hospital of the Air Force Medical University
Xi’an, Shanxi, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Lee SY, Seo HW, Jung SM, Lee SH, Chung JH. Assessing the accuracy and reliability of application-based audiometry for hearing evaluation. Sci Rep. 2024 Mar 28;14(1):7359. doi: 10.1038/s41598-024-57944-9.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
KY20242145zhadingjun
Identifier Type: -
Identifier Source: org_study_id
More Related Trials