Biodegradable Stents in Liver Transplant RecipIents for Treatment of Biliary Anastomotic Strictures
NCT ID: NCT06716541
Last Updated: 2024-12-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
70 participants
INTERVENTIONAL
2024-11-01
2027-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Biodegradable stents (BDS) are a novel type of stents made from various synthetic polymers or their copolymers, which are now being used in a variety of medical fields, including the pancreatobiliary tract.The use of biodegradable stents has shown good potential in the treatment of benign biliary strictures. However, overall data on their endoscopic use in liver transplant recipients, particularly in the treatment of anastomotic biliary strictures, are scarce. Most studies have either been in animal models, using percutaneously implanted stents, or in non-transplanted patients. There are no randomised controlled trials investigating their use in LT patients. Based on the available evidence, the use of BDS in the treatment of anastomotic biliary strictures in liver transplant recipients appears to be a promising technique that may be as effective as the standard treatment with MPS, but may reduce the number of ERCP procedures and eliminate the risk of migration.
The aim of this randomised prospective study is to compare the difference in rates of anastomotic stricture resolution between the active (BDS) and control (MPS) groups to demonstrate non-inferiority of the biodegradable stents. Outcomes will be classified as complete resolution (no significant stricture at the anastomotic site on imaging and resolution of cholestasis), significant response (relative stricture and resolution of cholestasis) or failure (persistent stricture and/or persistent cholestasis). Secondary outcomes are technical feasibility, immediate and late complications.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Biliary complications (BCs) following liver transplantation are the leading source of morbidity and liver graft failure and are associated with up to 10% mortality rate. The incidence of BCs remains high, being reported in 10-25% in cadaveric donors (DDLT) and in more than 30% in living donor liver transplantations (LDLT), despite improved both preoperative and postoperative care and enhanced surgical technique. Anastomotic biliary strictures (ABS) are together with bile leaks the most common biliary complication occurring any time after LT, but being primarily found within the first year LT. The incidence ranges between 5-15% in DDLT and 13-36% in LDLT. Anastomotic strictures are typically present at the site of anastomosis, tend to be short, single and constitute up to 86% of all biliary strictures. The clinical presentation can differ from patients being asymptomatic to some presenting with symptoms of biliary obstruction (jaundice, fever, chills, nausea, abdominal pain). The clinical picture can resemble also other conditions and it is important to differentiate biliary complication (BC) from other similarly presenting entities such as acute rejection, hepatic artery thrombosis, recurrence of primary sclerosing cholangitis or acute hepatitis). The gold standard for diagnosis of BCs is MRCP with reported sensitivity and specificity of up to 95%.
The first line therapy of BCs is endoscopic retrograde cholangiopancreatography (ERCP), in case of failure or altered anatomy percutaneous approach may be indicated. If both methods fail surgery is required. ERCP is an invasive endoscopic technique used primarily for therapy of pancreatobiliary tract. It is associated with risk of complications such as acute pancreatitis, bleeding, acute cholangitis or in rare cases perforation.
There are two standard approaches in the treatment of anastomotic biliary strictures, similarly to the treatment of other benign strictures of the bile duct. First, the use of multiple plastic stents (MPS) requiring their repeated endoscopic exchanges may be employed. Alternatively, a single self-expandable metal stent is placed for a longer period of time.
The endoscopic therapy of anastomotic strictures using multiple plastic stents typically requires multiple stent exchanges, starting with placing a single stent and adding multiple stents during further sessions. The sessions are scheduled every 1 to 3 months. The resolution of the anastomotic stricture is usually achieved in 12months, exposing the patient typically to 3-4 ERCP procedures. MPS technique was firstly described and put in practice in a single center study by Costamagna et al. with clinical success rate in 89%. After that many other studies have been published regarding this topic, including a meta-analysis, where the resolution rate of strictures were reported in 94%-100%. Finally in 2017 by Koksa et al. was reported a review demonstrating that in patients with more than 12 months of stenting, with higher total number of stents and number of stents inserted per session, a higher resolution rate and a lower recurrence rate were showed. Alternative option for the endoscopic treatment of ABS is the use of a single fully covered self-expandable metal stent (FC-SEMS), in studies showing similar rates of ABS resolution compared to MPS method with the advantage of not repeating ERCP to place multiple stents, although with higher risk of migration.
The use of endoscopically inserted biodegradable stents is a novel technique with a potential to overcome some downsides of standard treatment with MPS and FC-SEMS. Biodegradable stents are made of different synthetic polymers or their co-polymers. First use of biodegradable stents in the GI tract was described in the setting of an esophageal stricture in 1996 and was later used in small intestine and colon for benign strictures. In the pancreatobiliary tract biodegradable stents have begun to be used in the recent years, mostly for benign biliary strictures such as those caused by chronic pancreatitis and in postoperative cystic duct leaks. Most of the reported experience comes from percutaneously inserted stents. The experience with endoscopic insertion of biodegradable stents is very limited and the data about use of biodegradable stents in liver transplant recipients are extremely scarce.
A systematic review on the use of biodegradable stents in biliary tract by Siiki at al. reviewed studies from 1997 to 2017. This review included 12 animal and 7 human studies. In human studies biodegradable stents were inserted in 4 studies percutaneously and in 3 studies endoscopically. The main indications were benign biliary strictures, postoperative cystic duct leaks, leaks from hepaticojejunal anastomosis, strictures of hepaticojejunal anastomosis, bilioenteric anastomosis strictures or chronic pancreatitis. In all studies stents made out of polydioxanone with time of degradation between 3-6 months were used. The studies proved good feasibility and safety of BDS in both animal and human setting and demonstrated their successful use in the treatment of benign biliary strictures and cystic bile duct leaks. In the first and biggest study with the endoscopic use of biodegradable stents in humans in treatment of cystic duct leaks and benign biliary strictures (BBS), the overall clinical success rate in treatment of BBS was noted in 83% with no secondary hyperplastic strictures. Surprisingly quite high rate of acute cholangitis occurred, in 23% after 90 days, although all cases were mild.
In another recent systematic review and metanalysis by Almeida et al. biodegradable stents were compared to multiples plastic stent implantation in benign biliary strictures. In total 9 studies met the inclusion criteria and were analyzed. Biodegradable stent group (BDBS) consisted of one retrospective and two prospective cohort studies, where stents were deployed both endoscopically and percutaneously with a minimal follow up of 20,8 months. In contrast the MPS group consisted of one randomized control trial comparing the use of multiple plastic stents to FCSEMS for different types of benign biliary strictures, and 5 cohort studies from which were 4 retrospective and one was prospective with a minimal follow up of 78,4 months. The overall success rate to achieve long-term stricture resolution was 83% for the BDBS group and 84% for the MPS group. The average number of interventions in the MPS group was 3 in contrast to 1 in the BDBS group (per case). In a majority of cases the stents were placed percutaneously and only one cohort study included endoscopically released BDBS (13 patients). The treatment-related complication rate was reported for acute cholangitis, acute pancreatitis, stent migration and abdominal pain and was 24,1%, 0,7 %, 1,5 %, 0, 8% for BDBS and 6,1%, 2,7%, 6,8% and 6,8 % for MPS.
An observational single center study by Dopazo et al. reported 20 adult and pediatric patients where BDS were used for benign biliary strictures after liver transplantation using a transhepatic approach. The overall feasibility was 100%, the overall clinical success including both anastomotic and nonastomotic strictures was 75%. The clinical success was higher in anastomotic strictures (81,25%). Only one case of acute pancreatitis was observed.
Based on the available evidence, BDS have shown promising results with good stent patency, feasibility, efficacy and safety profile. Therefore, BDS may represent a novel treatment modality and an alternative to current techniques in the management of biliary anastomotic strictures with a reduced number of ERCPs. However, prospective comparative data are needed.
The investigators aim to compare the use of biodegradable stents with the multiple stenting technique using plastic stents for the treatment of biliary anastomotic strictures and to demonstrate the non-inferiority of biodegradable stents, as well as the safety profile and technical feasibility.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Management of anastomotic biliary strictures with biodegradable stents
Initially, a single biodegradable stent is used for treatment of an anastomotic biliary stricture. If needed, this may be followed by usage of another biodegradable stent or plastic stents.
ERCP implantation of a biodegradable stent
Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a biodegradable stent to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).
ERCP implantation of plastic stents
Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent or multiple stents to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).
Management of anastomotic biliary strictures with multiple plastic stents in
Multiple plastic stents are used for treatment of an anastomotic biliary stricture.
ERCP implantation of plastic stents
Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent or multiple stents to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ERCP implantation of a biodegradable stent
Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a biodegradable stent to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).
ERCP implantation of plastic stents
Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent or multiple stents to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Liver transplant recipients
* Duct-to-duct biliary anastomosis
* Anastomotic biliary stricture (cholestasis unexplained by other causes and/or liver biopsy showing altered biliary drainage and/or anastomotic stricture on MRCP)
* Signed informed consent
Exclusion Criteria
* Physical and/or psychological inability to understand the aims of the research and to adequately cooperate
* Pregnancy
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Institute for Clinical and Experimental Medicine
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tomas Hucl
Chairman, Department of Gastroenterology and Hepatology
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Tomas Hucl, Prof
Role: PRINCIPAL_INVESTIGATOR
Institute for Clinical and Experimental Medicine
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Institute for Clinical and Experimental Medicine, Department of Gastroenterology and Hepatology
Prague, , Czechia
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Tomas Hucl, Prof
Role: primary
Iveta Matulova
Role: backup
Tomas Hucl, Prof
Role: backup
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IKEM BDS
Identifier Type: -
Identifier Source: org_study_id