Transcatheter Tricuspid Valve Replacement Using the Lux-Valve Plus System

NCT ID: NCT06714500

Last Updated: 2024-12-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ENROLLING_BY_INVITATION

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-09-18

Study Completion Date

2026-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Tricuspid regurgitation (TR) is a common disease, and the tricuspid valve (TV) is no longer a "forgotten valve". Open heart surgery for isolated TR is uncommonly performed due to high operative risk (8-10% mortality). However, TR is associated with increased morbidity and mortality. There exists an unmet clinical need for less invasive intervention to treat TR. Transcatheter edge to edge repair (TEER) is a technique that is shown to be safe and effective in TR reduction and is associated with significant symptom improvement. However, a significant portion of TV anatomy are not suitable to be treated with TEER (e.g. coaptation gap \>10mm). A wide variety of technologies has been developed in recent years. Transcatheter tricuspid valve replacement (TTVR) is one of the more promising option for tricuspid regurgitation (TR) patients at high risk for surgery. A previous study reported that transcatheter tricuspid devices, which were employed with the radial force between the device and tricuspid annulus, were radial force-dependent. However, this radial force for valve fixation may cause complications, such as conduction block and right coronary artery impingement. The LuX-Valve (Jenscare Biotechnology) is a radial force-independent orthotopic TTVR device. The feasibility and efficacy of this device have been reported by several studies. However, this valve was implanted through right atrial access, where a small incision of the right chest and right atrium is needed. The LuX-Valve Plus valve replacement system is the second-generation version of the LuX-Valve and can be implanted through the jugular vein. The first-in-human implantation was recently performed. The study aims to assess the feasibility, safety and efficacy outcome of the Lux Valve Plus system in a cohort of otherwise no surgical option patients with severe symptomatic tricuspid regurgitation despite optimal medical therapy.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Tricuspid Regurgitation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Intervention

Group Type EXPERIMENTAL

LuxValve PLlus

Intervention Type DEVICE

The LuX-Valve (Jenscare Biotechnology) is a radial force-independent orthotopic TTVR device. The feasibility and efficacy of this device have been reported by several studies (11-13). However, this valve was implanted through right atrial access, where a small incision of the right chest and right atrium is needed. The LuX-Valve Plus valve replacement system is the second-generation version of the LuX-Valve and can be implanted through the jugular vein.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

LuxValve PLlus

The LuX-Valve (Jenscare Biotechnology) is a radial force-independent orthotopic TTVR device. The feasibility and efficacy of this device have been reported by several studies (11-13). However, this valve was implanted through right atrial access, where a small incision of the right chest and right atrium is needed. The LuX-Valve Plus valve replacement system is the second-generation version of the LuX-Valve and can be implanted through the jugular vein.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients aged 50- to 90-year-old
* Severe symptomatic tricuspid regurgitation (NYHA III-IV) despite optimal medical therapy
* Deem high risk for tricuspid valve surgery determined by a multidisciplinary heart team (including cardiologists, cardiac surgeons and cardiac anesthetists)
* Anatomically not feasible with other transcatheter tricuspid valve therapy that is commercially available in Hong Kong (i.e. TriClip System)
* Capacity to provide informed consent

Exclusion Criteria

* Systolic pulmonary artery pressure (sPAP) \> 60 mmHg assessed by echocardiography
* Left Ventricular Ejection Fraction (LVEF) \<40%
* Evidence of intracardiac mass, thrombus or vegetation
* Anatomical structures precluding proper device deployment or device vascular access, evaluated by echo or CT
* Surgical correction is indicated for other concomitant valvular disease (e.g., severe aortic, mitral and/or pulmonic valve stenosis and/or regurgitation); Subjects with concomitant valvular disease may treat their respective valve first and wait 2 months before being reassessed for the trial.
* Sepsis or active endocarditis within 3 months, or infections requiring antibiotic therapy within 2 weeks prior to the planned procedure
* Active peptic ulcer or active gastrointestinal (GI) bleeding precluding anticoagulation or antiplatelet therapy
* Subjects currently participating in another clinical trial of an investigational drug or device that has not yet completed its primary endpoint.
Minimum Eligible Age

50 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Prince of Wales Hospital, Shatin, Hong Kong

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr So Chak Yu kent

Principle Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Kent So, PI

Role: PRINCIPAL_INVESTIGATOR

Chinese University of Hong Kong

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Prince of Wales Hospital

Hong Kong, Shatin, Hong Kong

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Hong Kong

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2023.029

Identifier Type: -

Identifier Source: org_study_id