Conventional Versus Automated Bag-based Mechanical Ventilator to Support ARDS Patients

NCT ID: NCT06667375

Last Updated: 2024-10-31

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

87 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-01-19

Study Completion Date

2022-12-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study evaluates the extubation success and compares the survival rate in patients with signs of Covid-19 intubated with Masi, a novel type of mechanical ventilator, or with other conventional ventilators admitted in the ICU of a reference hospital in Lima, Peru between January and August 2021. The Masi mechanical ventilator works by automating a resuscitation bag with promising preclinical results. The key features of Masi are its low manufacturing cost, low dependence on a supply of high volumes of oxygen, low oxygen consumption, flexibility between non-invasive and invasive ventilation, and extended range of working environmental altitudes compared to commercially available ventilators. A retrospective study of variables and outcomes was done. The main goal of this study is to compare the survival rate of respiratory failure patients supported either with Masi or conventional ventilators at Hospital Vitarte II in Lima between January and August 2021.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The translation of novel technologies for Intensive Care Units (ICU) including mechanical ventilators has been mostly about incremental improvements through increasing features assuming the presence of highly trained personnel and dedicated infrastructure such as permanent power supply and high oxygen flow. Despite the long history of use of mechanical ventilators, the Covid-19 pandemic demanded innovation to meet worldwide demands for this type of life support equipment. The inadequacy of the commercially available ventilators has been mostly attributed to weak fabrication and supply chains and inconsistencies between the required sanitary infrastructure and human resources available for which most commercial ventilators have been designed. Diverse approaches addressed the design and development of low-cost and more available mechanical ventilators worldwide achieving various levels of clinical implementation.

In Peru, the Masi (companion in Quechua) ventilator was developed based on concepts of the MIT Emergency Ventilator (MIT E-Vent) by automating a resuscitation bag. The Masi initiative showed promising pre-clinical results that allowed the production of more than 250 units under an exceptional permit to be used clinically in Peru only when no other ventilators were available. The key features of this technology are its low manufacturing cost, low oxygen consumption, flexibility between non-invasive and invasive ventilation, and extended range of working environmental altitudes compared to commercially available ventilators. Clinical characteristics, blood chemistry information, respiratory parameters, and survival rates were analyzed for 77 patients (42 ventilated by Masi, 35 ventilated by commercial ventilators).

This is an observational retrospective cohort study. The study protocol was approved by the Research Ethics Committee for Life Sciences and Technology of the PUCP (002-2021-CEICVyTech/PUCP) on September 23, 2021. A total of one hundred and three (103) patients were admitted to the ICU between January 19, 2021 until August 27, 2021, which coincides with the second Peruvian wave of the Covid-19 pandemic in the Hospital Vitarte II in Lima, Peru. Data from patients who were diagnosed with Covid-19, with signs of Acute Respiratory Distress Syndrome (ARDS), intubated, and connected to a mechanical ventilator in the ICU were de-identified for this study. From the 132 variables collected into the Electronic Health Records, only 120 selected variables were transcribed into an electronic database (Microsoft Excel V). The data was standardized and entered by a physician trained in Good Clinical Practice (Data Entry Investigator) following a Data Dictionary.

After data cleanup, this study retrospectively analyzed data from eighty-seven (87) patients who had a positive Covid-19 diagnosis and used a mechanical ventilator machine. According to the Peruvian regulatory agency, DIGEMID, Masi was indicated only when no conventional ventilator was available, and a patient needed one as determined by the ICU physician. The physicians used their criteria to prescribe Masi or other available ventilator brands.

During the described period, the ICU of the Hospital Vitarte II had seven beds and four conventional ventilators: Evolution (EVL100001-T-NF), Vela (16532-07), Newport (e360) and Dragger (Savina 300). Eight new individually validated ventilators known as Masi were provided to the ICU, and the medical personnel were trained regarding its clinical use. This device was approved to be used in Peru during the sanitary emergency by the local competent authority: Dirección General de Medicamentos, Insumos y Dispositivos Médicos (DIGEMID, Spanish acronym) based on preclinical evidence of safety.

To avoid bias derived from the convenience sampling of a single-site study, the Data Entry Investigator reviewed the medical charts corresponding to every patient (n=103) admitted into ICU at the site during the study range across Masi before selecting the charts to be included. A selection was made from the initial 132 variables recorded based on relevance for the present study. Variables from the initial database were uploaded into R studio. The variables and values were reviewed by two independent data analysts and queried to the data entry assistant when necessary. The dataset was cleaned up, and variables were normalized and categorized. Each variable was evaluated with a univariate analysis followed by a bivariate analysis comparing different results between pre- and post-intubation, and post and last-intubation measurements. The main factors used for comparison were the respiratory parameters before and after the intubation between the mechanical ventilators Masi versus conventional. An additional analysis was done to compare survival rates by using the Kaplan-Meier estimator and COX analysis. A sensitivity analysis was done to each model to evaluate suitability for a non- parametric and semi-parametric test.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Acute Respiratory Distress Syndrome (ARDS)

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Ventilators Medical devices, Data analysis Technological innovation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Masi

Patients who were diagnosed with Covid-19, with signs of Acute Respiratory Distress Syndrome (ARDS), intubated, and connected to an automated-bag mechanical ventilator in the ICU

No interventions assigned to this group

Conventional

Patients who were diagnosed with Covid-19, with signs of Acute Respiratory Distress Syndrome (ARDS), intubated, and connected to a commercial mechanical ventilator in the ICU

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients hospitalized to ICU requiring mechanical ventilation during COVID-19 pandemic
* Over 18 years old

Exclusion Criteria

\- None
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

EsSalud Hospital Vitarte (HOSPITAL II VITARTE ESSALUD)

UNKNOWN

Sponsor Role collaborator

Fanny Lys Casado Pena

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Fanny Lys Casado Pena

Full Professor

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Fanny L Casado Peña, PhD

Role: PRINCIPAL_INVESTIGATOR

Pontificia Universidad Catolica del Peru

Sergio Sánchez-Gambetta, MD, MSc

Role: PRINCIPAL_INVESTIGATOR

Pontificia Universidad Catolica del Peru

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Pontificia Universidad Católica del Perú

Lima, , Peru

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Peru

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

002-2021-CEICVyTech/PUCP

Identifier Type: -

Identifier Source: org_study_id