Bacterial Microleakage and Bone Loss in Internal Connection Dental Implants Based on the Type of Abutment Used in Zirconia Partial Fixed Prosthesis: in Vivo Study
NCT ID: NCT06156111
Last Updated: 2023-12-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
20 participants
INTERVENTIONAL
2020-02-26
2023-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Participants will:
* Receive two fixed partial monolithic zirconia CAD/CAM prothesis, one will be attached to an abutment (control group) and the other not (test group)
* Subsequently, control appointments of the fixed implant supported prosthesis treatment will be performed (1, 3,6, 12 and 24 months) and radiographies will be made with the parallelizing device attached by the silicone key.
Researchers will compare fixed partial monolithic zirconia CAD/CAM implant-supported prostheses with and without abutment to see:
* Differences in bacterial micro-leakage on interfaces.
* Occurrence of peri-implant diseases and bone loss
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Since the discovery of osseointegration by Branemark, dental implant treatment has been growing in importance for the replacement of missing teeth until it has become the treatment of choice in most cases of partial and total tooth absences. Although in the beginning, implants were used to hold mandibular prostheses, they had a smooth surface, and the connection they presented on their platform was an external hexagon. These characteristics were established empirically in the absence of previous experience. Currently, implants are one of the most widely used dental treatments and have evolved both in their indications and in their design. Regarding their indications, they are used for the treatment of all types of edentulism, from a unitary implant to the rehabilitation of a complete arch. On the other hand, in terms of design, the modifications and variables are so numerous that it is impossible to list them all, but fundamentally, it has progressed on the surface, macroscopically and microscopically, achieving a greater proportion of tooth-implant union, and in the connection, moving from the initial external hexagon to internal connections with different designs: hexagonal, octagonal, morse cone, and hexagon, with the aim of preventing the complications that can appear in this type of prosthesis, both mechanical (the most frequent being loosening of the screw) and biological (mainly bacterial microfiltration).
The mismatch at the level of the junction between implant-abutment or implant-prosthesis in the case of a prosthesis directly screwed to the implant(s) has been and is one of the workhorses in implantology due to the influence it has on bacterial microfiltration, and this is demonstrated by the large number of studies that exist on this subject. In an ideal situation, this mismatch should not exist and should be cero, so that the bacteria existing in the oral microflora could not filter and accumulate in that implant attachment or implant prosthesis junction. In reality, it is impossible to achieve that perfection goal even in the manufacture of prefabricated machined parts and for unit implants, since a dimensional margin is necessary to allow their correct settlement, especially when connected directly to the implant (without the intermediation of a prefabricated abutment) by individualized manufacturing processes. That is why, from this point of view, it would be advisable to use prefabricated abutments in all cases of partial prostheses in order to keep the possible misalignment of the prosthesis away from the implant-attachment joint. This mismatch, however, must be understood not only as evaluated by different studies as a linear discrepancy but also from a three-dimensional point of view, since once it is accepted that the perfect fit does not exist, microfiltration will occur to a greater or lesser extent depending on the design of the connection; for example, it will not be the same in an external hexagonal connection as in an internal octagonal one.
The importance of bacterial microfiltration at the level of the implant-abutment junction from a clinical point of view is of special relevance since the accumulation of bacteria at that level, in most cases subgingival, could be directly related to the colonization of anaerobic bacteria, more aggressive, in locations that are difficult to access for sanitization by the patient. in such a way that they could favor the beginning of pathological bone destruction and the development of a peri-implant disease, complications of relative frequency, and that can be defined as infectious processes that occur in the tissues around the implants. When the inflammation around the implants presents with bone loss, bleeding, and/or suppuration on probing, it is considered peri-implantitis. It is a complication that is complicated and difficult to treat since the surface of the implant is contaminated and non-surgical treatments are usually insufficient to clean it, while surgical treatments are not only more aggressive but are also not inflatable and can also lead to aesthetic complications due to retraction of the soft tissues and even the exposure of the implant itself (metallic in most cases).
On the other hand, as for the implant prosthesis itself, its evolution since its origins with respect to its design and materials has also been very important. Among the materials used today to make fixed prostheses on implants, one of the most important is zirconia. Its use has become widespread because it has qualities that improve the materials considered until recently the gold standard, which were made with a metal structure (Titanium, Cr-Co, Cr-Ni, Cr-Ni, Cr-Ni-Pa, Pa-Co, etc.) and the aesthetic coating of porcelain, added by a brushstroke process carried out by a laboratory technician and then fired in processing ovens. Among the advantages of zirconia are: its CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) manufacturing, i.e., computer design and manufacturing by milling process (as it can be milled in a softer, pre-synthesized phase, improves metal milling, makes it cheaper, and involves much less wear); its biocompatibility; and its aesthetics, as it is a white material. This quality allows the creation of prostheses without the need for aesthetic coating, known as monolithic zirconium. This modality, monolithic zirconium, is one of the most used treatment alternatives in fixed prostheses on implants because it also manages to solve one of the most frequent mechanical complications in fixed prostheses on implants, which is the porcelain jump or chipping. The term "chipping" is defined as "the detachment of one material attached to another when subjected to a load, separating the two".
When prostheses are rehabilitated on teeth with monolithic zirconia, the procedure is similar to the gold standard (metal-porcelain); however, when rehabilitating prostheses on implants, we must consider that the peculiarities of zirconia discourage its direct screwing to the implant since its lower resistance to compressive forces in thin thicknesses causes them to fracture at the moment of definitive tightening of the prosthesis (torques of 30-40 Ncm). In addition, in the event of loosening of the prosthesis, its great hardness means that the movements between the implant and prosthesis cause the internal surface of the connection to be worn, which can even lead to the need to remove the implant as it becomes unusable. For this reason, monolithic zirconium on implants is made on metal abutments or interfaces, to which it is joined by a cementing process. Within these attachments, when used in implants with internal connection, there are those with connection (they fit into the implant connection) or flat or without connection (they remain at the level of the implant platform but do not penetrate it). The latter are easier to use in all cases since the implant-abutment fit is easier and hardly complicated in cases of angled implants, but they leave an "unfilled" space within the internal surface of the implant, which could lead to greater bacterial microfiltration, with the possible influence on the development of peri-implant diseases that has been explained above.
Based on this background, the following in vivo study is carried out to assess whether the use of connected or unconnected abutments influences bacterial microfiltration, the development of peri-implant diseases, and bone loss at that level in partial prostheses on monolithic zirconia CAD/CAM implants.
HYPOTESIS
Taking into account the importance of microfiltration at the level of the implant-abutment junction and its relationship with the development of peri-implant diseases, and the increase in fixed implant rehabilitations performed by CAD/CAM in monolithic zirconia, its study is considered of great importance, proposing the following hypotheses and objectives:
* Null hypothesis 1: There are no differences in bacterial microfiltration in partial prostheses performed by CAD/CAM in monolithic zirconium with abutments and without abutments.
* Null hypothesis 2: there are no differences in the development of peri-implant diseases and bone loss in partial prostheses performed using CAD/CAM in monolithic zirconium with abutments and without abutments.
OBJECTIVES
1. To observe if there are differences in bacterial microfiltration in fixed partial implant-supported prostheses performed by CAD/CAM in monolithic zirconium with and without abutment.
2. Assess whether there are differences in the occurrence of peri-implant diseases and bone loss in partial prostheses performed by CAD/CAM in monolithic zirconium with abutment and without abutment.
These objectives are in line with those proposed by the State Research Agency in its call for R+D+i research projects "RESEARCH CHALLENGES", being identified within the challenge "Health, demographic change, and well-being", being considered relevant within oral prosthetic treatments, and also being highly topical objectives whose contribution, with the aim of being published in journals within the Journal of Citation Report, will have an impact on the treatment of implant prostheses and their incidence in the development of peri-implantitis and peri-implant diseases.
MATERIAL AND METHODS
Study design
Longitudinal parallel prospective double blinded clinical trial.
Study population
The study population will consist of patients seen at the School of Dentistry of the Complutense University of Madrid, of both sexes, over 18 years of age, who require as treatment the replacement of teeth with two fixed partial prostheses supported by implants and who meet all the inclusion criteria but none of the exclusion criteria. This way the study could be carried out "with a split mouth" design rehabilitating one of them with zirconia bridges with abutments connection and others with zirconia bridges with unconnected abutments.
Once the informed consent has been read and explained, and any possible doubts regarding the treatment and the study have been resolved, patients must give their written informed consent to participate in the study prior to any study-related procedure.
Study Sample and sample size
15 patients will be selected who come for treatment at the school of Dentistry of Complutense University of Madrid and who require as treatment the replacement of teeth with two fixed partial prostheses on implants, in such a way that the study will be carried out "with a split mouth".
Methodology: Clinical procedures, data colection and information sources
Patients will be given the patient information sheet and will be explained any questions that may arise, as well as informed consent. The patient may revoke his or her participation in the study at any time he or she deems appropriate and without the need to give explanations.
Implants will be placed where there is sufficient bone availability and at least 4 months have elapsed since the only extraction, excluding locations where there are infectious focus or where bone regeneration procedures have been needed.
The prosthetic phase will be shifted following the osseointegration period. Prior to that, a parallelization technique will be used to take an initialx-ray. A silicone key will be made to help reposition the parallelizer in the same position so that all subsequent X-rays will be obtained in the same perspective, allowing for the monitoring of bone resorption, if it occurs.
In order to submit the models to the laboratory for the creation of the monolithic zirconia bridges-one on the implant-abutment connection and the other on the implant-crown connection-the appropriate records will need to be taken. Randomization will be used to determine which bridge will have abutments.
The fixed implant-supported prosthesis will undergo control/follow-up appointments at the first month and then every 3, 6, 12, and 24 months. During each appointment, peri-apical X-rays will be taken using the parallelizing device, which is held in place by the silicone key.
Ultimately, the images will be exported to a computer program (Image J/Photoshop) in which the radiographic loss will be measured for each follow-up period.
It will be verified during the patient's follow-up that there have been no biological or mechanical issues.The implants will be probed to assess bleeding at probing (BOP), document the presence of plaque, and study the peri-implant tissues to ascertain if they are healthy or have mucositis or peri-implantitis.
Additionally, a microbiological examination will be conducted, involving the collection of a sample using paper tips from the adjacent teeth and the implant conection of all implants in both study groups. The samples will then undergo PCR analysis to detect the presence of periodontopathogenic bacteria. Only patients who have had their restorations placed on implants and had at least a year of follow-up will have this microbiological sample obtained.
In the same methodical manner as when the prosthesis was placed, the occlusion and contact points will be examined, and their thickness will be measured using thickness sheets. Furthermore, an intraoral scan using the 3Shape Trios scanner will be carried out in order to assess any volumetric changes generated at the soft tissue level and determine whether the restorations or antagonists have worn down.
A questionnaire will be carried out, evaluating patient satisfaction (Annex 2d.).
STATISTICAL ANALYSIS
Since there are fewer than twenty samples in each group (n \< 20), the Kolmogorov-Smirnov will be used to determine whether the samples meet normal criteria. The ANOVA test for independent samples will be used in this study to statistically assess the fracture resistance as well as the level of microfiltration, provided that the normality criteria are met. All the examining variables are quantitative and independent. The non-parametric Kruskal-Wallis test for independent samples will be used instead if this condition is not satisfied.
STUDUY LIMITATIONS
The study's main limitations is the recruitment of patients since they have to be patients with edentations that allow their treatment with both types of prostheses for controlled comparison, that is, split mouth. In addition, they must be in good health and have good bone availability, which makes them susceptible to inclusion in the study.
CHRONOGRAM / WORK PLAN
Since the approval of the research project:
* Year 1: Detailed review of the new bibliography, fabrication of the in vitro study samples, and beginning of methodology (estimated: application of cyclic loading and 1/2 thermocycling in all groups). Patient selection, in vivo study, and implant placement
* Year 2: Continuation with the thermocycling phase and completion of the in vitro phase (bacterial infiltration and obtaining results), continuing with patient selection and implant placement, and beginning of the prosthetic phases of the implants already placed.
* Year 3: In vitro study: obtaining results, statistical analysis, and writing them for publication in JCR journals; clinical phase: continuation of case selection, alternating placement of implants (if cases are still missing),
PROTOCOL AMENDMENTS Protocol changes will be kept to a minimum. Only those changes that are deemed essential to the successful completion of the protocol will be considered.
PUBLICATION RIGHTS
Analysis of data will be conducted by Data Management. The final manuscript will be prepared by the principal investigator in conjunction with sub-investigators and submitted for publication. Additionally, the results of the study will be entered on clinicaltrials.gov.
If it's decided on the future sharing of the IPD the following data will be shared and available:
* Participant's data that underlie the results reported in this article, after identification (text, tables, figures).
* The data and protocols may be only available to investigators and researchers who provide a methodologically sound proposal for individual participant data meta-analysis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Transepithelial abutment
The patients randomized to the transepithelial abutment group will receive a fixed screw implant-supported zirconia prosthesis which will be attached to the implants through an implant-abutment connection.
Transepithelial abutment group
Before completing the essential clinical data registration to produce an individual patient-oriented prosthesis, trans-epithelial abutments on the implants randomized to this group will be put at the torque the manufacturer recommends (30 Ncm typically), according to the appropriate gingival height and then the fixed implant-supported monolithic zirconia will be placed at the torque of 15 Ncm
Direct to implant
The patients randomized to the direct to implant group will receive a fixed screw implant-supported zirconia prosthesis which will be attached direct to the implants connection.
Direct to implant group
It will be registered the essential clinical data registration to produce an individual patient-oriented prosthesis, and then the fixed implant-supported monolithic zirconia will be placed at the torque of 30 Ncm.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Transepithelial abutment group
Before completing the essential clinical data registration to produce an individual patient-oriented prosthesis, trans-epithelial abutments on the implants randomized to this group will be put at the torque the manufacturer recommends (30 Ncm typically), according to the appropriate gingival height and then the fixed implant-supported monolithic zirconia will be placed at the torque of 15 Ncm
Direct to implant group
It will be registered the essential clinical data registration to produce an individual patient-oriented prosthesis, and then the fixed implant-supported monolithic zirconia will be placed at the torque of 30 Ncm.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Being over 18 years old.
* Not being severe smokers (\>20 cigarettes/day)
* Not having diseases that can affect bone metabolism, such as arthritis and osteoporosis, and not having uncontrolled systemic diseases.
Exclusion Criteria
* Conditions or circumstances that, in the opinion of the investigator, would preclude completion of participation in the study or interfere with the analysis of the study results.
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universidad Complutense de Madrid
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Miguel Gómez Polo
Associate Professor of Conservative Dentistry and Prosthodontics
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Miguel Gómez Polo, DDS, PhD
Role: PRINCIPAL_INVESTIGATOR
UComplutense de Madrid
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
School of Dentistry, Complutense University. Pza Ramón y Cajal s/n.
Madrid, , Spain
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Smith NA, Turkyilmaz I. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values. J Prosthet Dent. 2014 Sep;112(3):561-7. doi: 10.1016/j.prosdent.2013.11.010. Epub 2014 Mar 20.
Baldassarri M, Hjerppe J, Romeo D, Fickl S, Thompson VP, Stappert CF. Marginal accuracy of three implant-ceramic abutment configurations. Int J Oral Maxillofac Implants. 2012 May-Jun;27(3):537-43.
Larrucea C, Conrado A, Olivares D, Padilla C, Barrera A, Lobos O. Bacterial microleakage at the abutment-implant interface, in vitro study. Clin Implant Dent Relat Res. 2018 Jun;20(3):360-367. doi: 10.1111/cid.12589. Epub 2018 Feb 15.
Alves DCC, de Carvalho PSP, Elias CN, Vedovatto E, Martinez EF. In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling. Clin Oral Investig. 2016 Dec;20(9):2437-2445. doi: 10.1007/s00784-016-1744-0. Epub 2016 Feb 20.
Elshiyab SH, Nawafleh N, George R. Survival and testing parameters of zirconia-based crowns under cyclic loading in an aqueous environment: A systematic review. J Investig Clin Dent. 2017 Nov;8(4). doi: 10.1111/jicd.12261. Epub 2017 Mar 19.
Gehrke SA, Delgado-Ruiz RA, Prados Frutos JC, Prados-Privado M, Dedavid BA, Granero Marin JM, Calvo Guirado JL. Misfit of Three Different Implant-Abutment Connections Before and After Cyclic Load Application: An In Vitro Study. Int J Oral Maxillofac Implants. 2017 Jul/Aug;32(4):822-829. doi: 10.11607/jomi.5629.
Bressan E, Stocchero M, Jimbo R, Rosati C, Fanti E, Tomasi C, Lops D. Microbial Leakage at Morse Taper Conometric Prosthetic Connection: An In Vitro Investigation. Implant Dent. 2017 Oct;26(5):756-761. doi: 10.1097/ID.0000000000000657.
Guerra E, Pereira C, Faria R, Jorge AO, Bottino MA, de Melo RM. The Impact of Conical and Nonconical Abutments on Bacterial Infiltration at the Implant-Abutment Interface. Int J Periodontics Restorative Dent. 2016 Nov/Dec;36(6):825-831. doi: 10.11607/prd.2779.
Butignon LE, Basilio Mde A, Pereira Rde P, Arioli Filho JN. Influence of three types of abutments on preload values before and after cyclic loading with structural analysis by scanning electron microscopy. Int J Oral Maxillofac Implants. 2013 May-Jun;28(3):e161-70. doi: 10.11607/jomi.2481.
Butignon LE, de Almeida Basilio M, Santo JS, Arioli Filho JN. Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading. Int J Oral Maxillofac Implants. 2016 Sep-Oct;31(5):1017-22. doi: 10.11607/jomi.4477.
Larrucea Verdugo C, Jaramillo Nunez G, Acevedo Avila A, Larrucea San Martin C. Microleakage of the prosthetic abutment/implant interface with internal and external connection: in vitro study. Clin Oral Implants Res. 2014 Sep;25(9):1078-83. doi: 10.1111/clr.12217. Epub 2013 Jul 4.
Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater. 2013 Feb;29(2):174-80. doi: 10.1016/j.dental.2012.10.012. Epub 2012 Dec 4.
Kim KB, Kim JH, Kim WC, Kim JH. Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies. J Prosthet Dent. 2014 Dec;112(6):1432-6. doi: 10.1016/j.prosdent.2014.07.002. Epub 2014 Sep 11.
Fernandez M, Delgado L, Molmeneu M, Garcia D, Rodriguez D. Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes. J Prosthet Dent. 2014 Feb;111(2):116-23. doi: 10.1016/j.prosdent.2013.09.006. Epub 2013 Oct 28.
Tartaglia GM, Sidoti E, Sforza C. Seven-year prospective clinical study on zirconia-based single crowns and fixed dental prostheses. Clin Oral Investig. 2015 Jun;19(5):1137-45. doi: 10.1007/s00784-014-1330-2. Epub 2014 Oct 12.
Guess PC, Att W, Strub JR. Zirconia in fixed implant prosthodontics. Clin Implant Dent Relat Res. 2012 Oct;14(5):633-45. doi: 10.1111/j.1708-8208.2010.00317.x. Epub 2010 Dec 22.
Lang NP, Berglundh T; Working Group 4 of Seventh European Workshop on Periodontology. Periimplant diseases: where are we now?--Consensus of the Seventh European Workshop on Periodontology. J Clin Periodontol. 2011 Mar;38 Suppl 11:178-81. doi: 10.1111/j.1600-051X.2010.01674.x.
Zarone F, Russo S, Sorrentino R. From porcelain-fused-to-metal to zirconia: clinical and experimental considerations. Dent Mater. 2011 Jan;27(1):83-96. doi: 10.1016/j.dental.2010.10.024. Epub 2010 Nov 21.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
18/426-E
Identifier Type: -
Identifier Source: org_study_id