Evaluation of Gastric Content of Volunteers Fasting and Using Semaglutide: an Observational and Cross-sectional Study
NCT ID: NCT06154486
Last Updated: 2023-12-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
30 participants
OBSERVATIONAL
2023-06-19
2023-08-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Obesity and type 2 diabetes mellitus constitute a global public health problem. Medications with glucagon-like peptide-1(GLP-1) receptor agonist action are a modern therapeutic option for both diseases. Liraglutide, semaglutide and dulaglutide are some representatives of this drug class, whose mechanism of action results in slowing gastric emptying, reduced gastric motility, and increased gastric volume These effects are implicated in both weight loss and the occurrence of adverse events such as nausea, vomiting, acute gastroparesis and gastroesophageal reflux disease (GERD) The presence of gastric contents during the anesthetic procedure can lead to pulmonary aspiration and the development of chemical pneumonitis, a potentially fatal complication. To avoid this risk, in healthy patients, an 8-hour fast for solids and 2 hours for clear liquids. However, when there is a risk factor for slow gastric emptying, despite adequate fasting, the stomach may present residues and bedside ultrasound is an effective, non-invasive and quickly to measure this content and stratify the risk of aspiration Due to the lack of studies demonstrating that the use of GLP-1 analogue can increase the risk of aspiration in individuals who are fasting adequately to receive anesthesia, there is no formal recommendation for performing gastric ultrasound in the preoperative period, nor for the suspension of these medications. Some institutions empirically recommend suspension preoperatively.
Given the severity of the occurrence of bronchoaspiration, the biological action of GLP-1 analogues on gastric function and the incremental use of these medications, it is necessary to better understand the gastric contents of individuals fasting and using a GLP-1 analogue. GLP-1. Thus, through ultrasound, we will aim to evaluate the gastric contents of volunteers who do not have risk factors for bronchoaspiration, who will not undergo anesthesia, but are fasting recommended for this purpose and are using semaglutide, a GLP-1 analogue.
Our hypothesis is that the majority of individuals using these medications have a full stomach even with the fasting times recommended in the literature. In view of this, for this population we must adapt safety criteria during the anesthetic procedure.
Objectives Primary objective The primary objective is to evaluate the prevalence of a full stomach through gastric ultrasound examination in volunteers who use semaglutide and are fasting for at least 8 hours for solids and 2 hours for clear liquids. As a control group, we will use volunteers who do not use semaglutide.
Secondary objectives The secondary objectives consist of evaluating whether the demographic characteristics of the volunteers, the time of medication use, the time elapsed since the last dose of semaglutide received, the dose and regimen of medication use, the reason for using the medication, the presence Symptoms such as nausea, vomiting, loss of appetite and sensation of gastric fullness can influence gastric emptying when these individuals are evaluated by ultrasound.
Study Design Observational, cross-sectional, non-interventional study
study population
30 volunteers will be included in the study, of which 15 must be currently using semaglutide and 15 must not be using the medication. The gastric ultrasonography will be performed at Hospital Israelita Albert Einstein, in the radiologist medicine sector, by an anesthesiologist with experience in gastric ultrasonography. The images will be registered in the picture archiving and communication system and reviewed by a radiologist.
Sample size calculation Based on the literature, individuals in the control group presented an area of residual liquid in the stomach ranging from 3cm² to 7cm² with a median area of 5.1cm², which respectively provide 32.4ml, 90.8ml and 63.1ml of liquid volume. residual after 8 hours of fasting, assuming an average increase of at least 20ml of fluid in patients using semaglutide, with 95% confidence and 80% power, the sample required to carry out the study is 14 patients in each group. To compensate for any losses, we will increase the sample by 10%, leaving 15 volunteers in each group.
METHODS Study outcomes Primary outcome Compare the prevalence of a full stomach, after fasting for at least 8 hours for solids and 2 hours for clear liquids, through gastric ultrasound in volunteers using semaglutide with those who do not use the medication. The outcome will be binary: a full stomach includes the visualization of solids on gastric ultrasonography or a volume of clear liquids greater than 1.5ml/kg It will be considered an empty stomach when no content or clear liquids are visible inferior to 1.5ml/kg
Secondary outcomes
* Assess the demographic characteristics of the volunteers.
* Describe the dose and regimen of medication use.
* Describe the reason for using the medication.
* Describe the presence of symptoms such as nausea, vomiting and sensation of gastric fullness, loss of appetite, early satiety and abdominal pain.
* Describe the use of other medications.
Risk factors for bronchoaspiration
* Diabetes Mellitus with peripheral neuropathy or history of gastroparesis.
* Obesity. Defined as body mass index (BMI) inferior to 30 kg/m2.
* Active cancer.
* Gastroesophageal Reflux Disease.
* Use of opioids.
* History of surgery for obesity.
* Neurological disease.
* Chronic or acute kidney disease.
* Symptomatic hypothyroidism.
Technical limitation for evaluation of gastric contents by ultrasonography
* Previous gastric surgery such as partial gastrectomy or gastric bypass.
* Massive hiatus hernia.
Proper fasting
Fasting will be considered adequate:
* general diet: 8 hours
* Clear liquids (water, juices without lumps): 2 hours
Types of GLP-1 analogue
The following drugs will be considered:
• Semaglutide: Ozempic®️, Wegovy®️
Protocol for performing gastric ultrasonography
It consists of scanning the abdomen in the sagittal plane in the dorsal decubitus position at 45 degrees in the supine position and in the right lateral decubitus position with a curvilinear, low-frequency ultrasound probe(2 to 5 mHz) and locating the gastric antrum, through the identification of the main points of reference - left lobe of the liver and a main vessel, aorta or inferior vena cava. Gastric emptying will be assessed quantitatively and qualitatively, through assessment of the composition of its contents and measurement of gastric volume, respectively.
The qualitative assessment will assess whether the stomach is empty, with clear liquid or with solids. The stomach is considered empty when the antrum presents itself with the anterior and posterior walls juxtaposed, denoting a "buffalo eye" or "target" pattern, a characteristic attributed by the identification of a hypoechoic, thick external ring. The antrum may appear empty in the supine position and fluid-filled in the right lateral decubitus position. The volume of liquid must be measured in this position and if it is less than 1.5 ml/kg (average of 100ml in adults) it is considered normal in fasting individuals and the risk of bronchoaspiration is considered low. On the other hand, the visualization of liquid both in the supine position and in the right lateral decubitus position is suggestive of a large gastric volume. When the liquid measurement is greater than 1.5 ml/kg, the patient is at high risk for bronchoaspiration.
Whenever clear liquids are visualized, gastric volume is measured using the cross-sectional area of the gastric antrum(AA) using the external wall of the stomach, which has a linear correlation with gastric volume. This is performed in the right lateral decubitus position with two perpendicular diameters of the antrum, from serosa to serosa, the longitudinal or craniocaudal diameter(CC) and the anteroposterior diameter (AP) or using the ellipse formula developed by Bolondi where AA=(CC× AP × π) /4. With the value of π = 3.14. After calculating the AA, the total stomach volume ("predicted volume") will be evaluated in each volunteer with a previously tested and validated mathematical model, in which the stomach volume(ml) = 27 + 14.6 x AA (cm2) - 1.28 age (in years).
Collected variables Demographic data will be collected. Ultrasound images will be registered in the radiology picture archiving and communication system. Data will be collected in printed clinical records and/or an electronic form specifically developed for the study, using the REDCap@ (Research Electronic Data Capture) electronic form. The authors will be responsible for monitoring the data.
Demographic and baseline data.
* Verification of inclusion and exclusion criteria.
* Applicability and date of application of the informed consent form
* Date of birth.
* Age (in years).
* Gender.
* Ethnicity.
* Weight (in kg).
* Height (in cm).
* BMI (in kg/m2).
* Date of inclusion in the study.
Data regarding the GLP-1 analogue
* Semaglutide
* Ozempic®️
* Wegovy®️
* Administration dosage:
* Time of medication use in months or weeks, when time of use is less than 1 month.
* Previous use of semaglutide?
* Previous use of another medication from the GLP-1 analogue class?
* Reason for using the medication:
Clinical symptoms of gastroparesis
* Nausea
* Vomiting
* Abdominal pain
* Sensation of gastric fullness
* Early satiety
* Loss of appetite
Use of other medications
Data regarding gastric ultrasound examination
• Qualitative check
* Full stomach - solid residue or clear liquid volume\> 1.5 ml/kg
* Empty stomach - no content or volume of clear liquid Volume ≤ 1.5 ml/kg
STATISTICAL ANALYSIS Included patients will be divided into two groups according to the use or not of Semaglutide and the gastric residue found: a full stomach or an empty stomach. Differences between groups in relation to continuous numerical variables will be analyzed using the Student t test (normal distribution) or Mann-Whitney U test (variables not normally distributed). Proportions will be compared using the Chi-square test or Fisher's Exact Test, All significance probabilities (p values) presented will be two-tailed. p-values will be considered statistically significant when less than 0.05. All analyzes will be performed using the software R 3.4.1 (R Foundation for Statistical Computing, Vienna, Austria)
SAFETY AND ETHICAL CONSIDERATIONS Risks and benefits Abdominal ultrasound is a non-invasive exam that does not emit radiation. There is no evidence to support that the use of ultrasound can cause any harm to health. The research participant may experience some discomfort related to fasting for 8 hours for solids and 2 hours for liquids.
There are risks related to the loss of data confidentiality and the research team is responsible for taking all precautions to ensure data confidentiality.
This study may benefit individuals who use this medication when undergoing anesthesia. According to the results of this study, suspension of this medication preoperatively or other safety measures may be recommended.
Approval from ethical and regulatory authorities The study was approved by the Institutional review Board (IRB) and written consent from the patient will be requested.
Data confidentiality The patient will be identified by the corresponding number on the electronic data collection form. The data obtained must be kept confidential by the researchers and will be stored on the REDCAP Platform, which allows restricted access to information, according to security levels and individualized logins.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
CROSS_SECTIONAL
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
semaglutide group
patients without risk factors for gastroparesis, fasting for at least 8 hours, BMI less than 30 and currently using semaglutide
semaglutide use
patient using semaglutide for at least 7 days
control group
patients without risk factors for gastroparesis, fasting for at least 8 hours, BMI less than 30 and who have never used semaglutide or another GLP-1 analogue
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
semaglutide use
patient using semaglutide for at least 7 days
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Individuals currently using semaglutide.
* Individuals fasting for at least 8 hours for solids and 2 hours for clear liquids without residue.
Exclusion Criteria
* Individuals with technical limitations to perform gastric content assessment using ultrasonography
* Presence of risk factors for gastroparesis.
* Use of drugs from the prokinetic class, which accelerate gastric emptying, such as bromopride, metoclopramide and domperidone.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hospital Israelita Albert Einstein
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
veronica fialho
Role: PRINCIPAL_INVESTIGATOR
Hospital Israelita Albert Einstein
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hospital Israelita Albert Einstein
São Paulo, , Brazil
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Kalra S, Bhattacharya S, Kapoor N. Contemporary Classification of Glucagon-Like Peptide 1 Receptor Agonists (GLP1RAs). Diabetes Ther. 2021 Aug;12(8):2133-2147. doi: 10.1007/s13300-021-01113-y. Epub 2021 Jul 15.
Halawi H, Khemani D, Eckert D, O'Neill J, Kadouh H, Grothe K, Clark MM, Burton DD, Vella A, Acosta A, Zinsmeister AR, Camilleri M. Effects of liraglutide on weight, satiation, and gastric functions in obesity: a randomised, placebo-controlled pilot trial. Lancet Gastroenterol Hepatol. 2017 Dec;2(12):890-899. doi: 10.1016/S2468-1253(17)30285-6. Epub 2017 Sep 27.
Almustanyir S, Alhabeeb H, AlHusseini N, Al Thow M. Gastroparesis With the Initiation of Liraglutide: A Case Report. Cureus. 2020 Nov 28;12(11):e11735. doi: 10.7759/cureus.11735.
Warner MA, Meyerhoff KL, Warner ME, Posner KL, Stephens L, Domino KB. Pulmonary Aspiration of Gastric Contents: A Closed Claims Analysis. Anesthesiology. 2021 Aug 1;135(2):284-291. doi: 10.1097/ALN.0000000000003831.
Practice Guidelines for Preoperative Fasting and the Use of Pharmacologic Agents to Reduce the Risk of Pulmonary Aspiration: Application to Healthy Patients Undergoing Elective Procedures: An Updated Report by the American Society of Anesthesiologists Task Force on Preoperative Fasting and the Use of Pharmacologic Agents to Reduce the Risk of Pulmonary Aspiration. Anesthesiology. 2017 Mar;126(3):376-393. doi: 10.1097/ALN.0000000000001452. No abstract available.
Kruisselbrink R, Gharapetian A, Chaparro LE, Ami N, Richler D, Chan VWS, Perlas A. Diagnostic Accuracy of Point-of-Care Gastric Ultrasound. Anesth Analg. 2019 Jan;128(1):89-95. doi: 10.1213/ANE.0000000000003372.
Perlas A, Chan VW, Lupu CM, Mitsakakis N, Hanbidge A. Ultrasound assessment of gastric content and volume. Anesthesiology. 2009 Jul;111(1):82-9. doi: 10.1097/ALN.0b013e3181a97250.
Perlas A, Van de Putte P, Van Houwe P, Chan VW. I-AIM framework for point-of-care gastric ultrasound. Br J Anaesth. 2016 Jan;116(1):7-11. doi: 10.1093/bja/aev113. Epub 2015 May 7. No abstract available.
Bolondi L, Bortolotti M, Santi V, Calletti T, Gaiani S, Labo G. Measurement of gastric emptying time by real-time ultrasonography. Gastroenterology. 1985 Oct;89(4):752-9. doi: 10.1016/0016-5085(85)90569-4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
69273023.7.0000.0071
Identifier Type: -
Identifier Source: org_study_id