Trial Outcomes & Findings for Validation of the Performance of the Electrocardiogram (ECG) Function in the Masimo INVSENSOR00057 (NCT NCT06071754)

NCT ID: NCT06071754

Last Updated: 2025-10-31

Results Overview

Single Lead ECG, similar to lead I, intended to be used for Heart Rate measurement and AFib detection

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

365 participants

Primary outcome timeframe

Approximately 30 minutes

Results posted on

2025-10-31

Participant Flow

Participant milestones

Participant milestones
Measure
INVSENSOR00057
All subjects are enrolled into this arm and will have ECG measurements obtained Masimo INVSENSOR00057: Masimo INVSENSOR00057 will be used to collect electrocardiogram measurements.
Overall Study
STARTED
365
Overall Study
COMPLETED
356
Overall Study
NOT COMPLETED
9

Reasons for withdrawal

Reasons for withdrawal
Measure
INVSENSOR00057
All subjects are enrolled into this arm and will have ECG measurements obtained Masimo INVSENSOR00057: Masimo INVSENSOR00057 will be used to collect electrocardiogram measurements.
Overall Study
Device rhythm classifications not obtained from subjects due to protocol not being completed
9

Baseline Characteristics

Validation of the Performance of the Electrocardiogram (ECG) Function in the Masimo INVSENSOR00057

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
INVSENSOR00057
n=365 Participants
All subjects are enrolled into this arm and will have ECG measurements obtained Masimo INVSENSOR00057: Masimo INVSENSOR00057 will be used to collect electrocardiogram measurements.
Age, Categorical
<=18 years
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
199 Participants
n=5 Participants
Age, Categorical
>=65 years
166 Participants
n=5 Participants
Sex: Female, Male
Female
140 Participants
n=5 Participants
Sex: Female, Male
Male
225 Participants
n=5 Participants
Race/Ethnicity, Customized
Hispanic, Latino or Spanish
55 Participants
n=5 Participants
Race/Ethnicity, Customized
Non-Hispanic, Latino or Spanish
259 Participants
n=5 Participants
Race/Ethnicity, Customized
Not Reported
39 Participants
n=5 Participants
Race/Ethnicity, Customized
Asian
58 Participants
n=5 Participants
Race/Ethnicity, Customized
Black or African American
26 Participants
n=5 Participants
Race/Ethnicity, Customized
Native Hawaiian or Other Pacific Islander
2 Participants
n=5 Participants
Race/Ethnicity, Customized
White
209 Participants
n=5 Participants
Race/Ethnicity, Customized
Other
31 Participants
n=5 Participants

PRIMARY outcome

Timeframe: Approximately 30 minutes

Population: Masimo W1 rhythm classifications were not obtained from 9 subjects (3 from the NSR group, 6 from AFib group) due to the subject not completing the protocol.

Single Lead ECG, similar to lead I, intended to be used for Heart Rate measurement and AFib detection

Outcome measures

Outcome measures
Measure
INVSENSOR00057
n=356 Participants
All subjects are enrolled into this arm and will have ECG measurements obtained Masimo INVSENSOR00057: Masimo INVSENSOR00057 will be used to collect electrocardiogram measurements.
Validation of the Performance of the Electrocardiogram (ECG) Function in the Masimo INVSENSOR00057
Sensitivity
99.3 percent
Validation of the Performance of the Electrocardiogram (ECG) Function in the Masimo INVSENSOR00057
Specificity
100.0 percent

Adverse Events

INVSENSOR00057

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Chelsea Frank

Masimo Corporation

Phone: 949-297-7000

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place