Trial Outcomes & Findings for Examining Transcutaneous Vagal Nerve Stimulation as a Facilitator of Social Bonding (NCT NCT05899413)

NCT ID: NCT05899413

Last Updated: 2025-05-04

Results Overview

RSA was assessed continuously throughout the conversation.

Recruitment status

COMPLETED

Target enrollment

160 participants

Primary outcome timeframe

Continuously throughout conflict conversation

Results posted on

2025-05-04

Participant Flow

A total of 80 couples (i.e., 160 participants) were recruited from February 2024.

Couples were randomly assigned to either the active or sham stimulation condition after confirming their eligibility and completing a background questionnaire at home. Although all sessions were completed, technical issues (e.g., tVNS device malfunction) occurred in some cases. When this happened, the affected couple was excluded from the random assignment, and the next couple was reassigned to that condition.

Participant milestones

Participant milestones
Measure
Active tVNS
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal. In the sham stimulation condition, they will have the stimulation clip attached to their earlobe.
Sham tVNS
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Overall Study
STARTED
86
74
Overall Study
COMPLETED
86
74
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Examining Transcutaneous Vagal Nerve Stimulation as a Facilitator of Social Bonding

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Active tVNS
n=63 Participants
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal.
Sham tVNS
n=71 Participants
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Total
n=134 Participants
Total of all reporting groups
Age, Continuous
28.17 years
STANDARD_DEVIATION 4.33 • n=5 Participants
27.65 years
STANDARD_DEVIATION 4.26 • n=7 Participants
27.90 years
STANDARD_DEVIATION 4.29 • n=5 Participants
Sex/Gender, Customized
Female/Male/Other · Female
30 Participants
n=5 Participants
34 Participants
n=7 Participants
64 Participants
n=5 Participants
Sex/Gender, Customized
Female/Male/Other · Male
32 Participants
n=5 Participants
34 Participants
n=7 Participants
66 Participants
n=5 Participants
Sex/Gender, Customized
Female/Male/Other · Other
1 Participants
n=5 Participants
3 Participants
n=7 Participants
4 Participants
n=5 Participants
Race (NIH/OMB)
American Indian or Alaska Native
1 Participants
n=5 Participants
2 Participants
n=7 Participants
3 Participants
n=5 Participants
Race (NIH/OMB)
Asian
27 Participants
n=5 Participants
35 Participants
n=7 Participants
62 Participants
n=5 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Race (NIH/OMB)
Black or African American
0 Participants
n=5 Participants
3 Participants
n=7 Participants
3 Participants
n=5 Participants
Race (NIH/OMB)
White
33 Participants
n=5 Participants
23 Participants
n=7 Participants
56 Participants
n=5 Participants
Race (NIH/OMB)
More than one race
1 Participants
n=5 Participants
4 Participants
n=7 Participants
5 Participants
n=5 Participants
Race (NIH/OMB)
Unknown or Not Reported
1 Participants
n=5 Participants
4 Participants
n=7 Participants
5 Participants
n=5 Participants
Relationship duration
4.23 Years
STANDARD_DEVIATION 3.06 • n=5 Participants
4.41 Years
STANDARD_DEVIATION 2.41 • n=7 Participants
4.33 Years
STANDARD_DEVIATION 2.73 • n=5 Participants

PRIMARY outcome

Timeframe: Once, self-reported in a survey immediately following conflict interaction, up to 10 minutes

Population: Our analysis included 134 participants with complete physiological and self-report data. Missing data resulted from session failures (e.g., unstable or missing physiological measurements) or survey non-response

During the conversation, overall, I felt… (1: not at all positive, 7: extremely positive)

Outcome measures

Outcome measures
Measure
Active tVNS
n=63 Participants
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal.
Sham tVNS
n=71 Participants
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Self-reported Positive Affect
5.89 units on a scale
Standard Deviation 0.92
5.69 units on a scale
Standard Deviation 1.15

PRIMARY outcome

Timeframe: Once, self-reported in a survey immediately following conflict interaction, up to 10 minutes

Population: Our analysis included 134 participants with complete physiological and self-report data. Missing data resulted from session failures (e.g., unstable or missing physiological measurements) or survey non-response

During the conversation, overall, I felt… (1: not at all negative, 7: extremely negative)

Outcome measures

Outcome measures
Measure
Active tVNS
n=63 Participants
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal.
Sham tVNS
n=71 Participants
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Self-reported Negative Affect
5.79 units on a scale
Standard Deviation 1.18
5.62 units on a scale
Standard Deviation 1.32

PRIMARY outcome

Timeframe: Continuously throughout conflict conversation

Population: Our analysis included 134 participants with complete physiological and self-report data. Missing data resulted from session failures (e.g., unstable or missing physiological measurements) or survey non-response

RSA was assessed continuously throughout the conversation.

Outcome measures

Outcome measures
Measure
Active tVNS
n=63 Participants
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal.
Sham tVNS
n=71 Participants
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Respiratory Sinus Arrhythmia
6.47 ms
Standard Error 0.74
6.54 ms
Standard Error 0.89

PRIMARY outcome

Timeframe: Continuously throughout the conflict conversation

Population: Our analysis included 134 participants with complete physiological and self-report data. Missing data resulted from session failures (e.g., unstable or missing physiological measurements) or survey non-response

IBI was assessed continuously throughout the conversation.

Outcome measures

Outcome measures
Measure
Active tVNS
n=63 Participants
We delivered stimulation at the individually calibrated intensity continuously during the interactions, and the default device settings we adopted were as follows: frequency = 30Hz, phase duration = 250μs, interphase interval = 50μs, and max voltage = 65V. In the active stimulation condition, both partners will have the stimulation clip attached to the outer auditory canal.
Sham tVNS
n=71 Participants
In the sham condition, both partners will have electrodes attached to the center of the left ear lobe. They will still receive stimulation but at a placement that should not activate the vagus nerve.
Interbeat Interval
793.71 ms
Standard Deviation 101.74
808.20 ms
Standard Deviation 100.63

Adverse Events

Active tVNS

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Sham tVNS

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. Yoobin Park

University of California, San Francisco

Phone: 6289461325

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place