Trial Outcomes & Findings for Measuring Hydrogen Peroxide in Exhaled Breath Condensate in HV (NCT NCT05844553)

NCT ID: NCT05844553

Last Updated: 2024-06-06

Results Overview

Volunteer holds the device and breathes through the mouthpiece normally for a maximum of 5 minutes.

Recruitment status

COMPLETED

Target enrollment

20 participants

Primary outcome timeframe

6 months circa

Results posted on

2024-06-06

Participant Flow

Participant milestones

Participant milestones
Measure
Exhaled Breath Measurement
Patient Exhales into the device Measurement of inhaled measuring hydrogen peroxide in exhaled breath: Participant exhales from device
Overall Study
STARTED
20
Overall Study
COMPLETED
20
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Exhaled Breath Measurement
n=20 Participants
Patient inhales from device Measurement of inhaled measuring hydrogen peroxide in exhaled breath: Participant exhales from device
Age, Categorical
<=18 years
0 Participants
n=20 Participants
Age, Categorical
Between 18 and 65 years
20 Participants
n=20 Participants
Age, Categorical
>=65 years
0 Participants
n=20 Participants
Age, Continuous
34.5 years
STANDARD_DEVIATION 12.2 • n=20 Participants
Sex: Female, Male
Female
12 Participants
n=20 Participants
Sex: Female, Male
Male
8 Participants
n=20 Participants
Region of Enrollment
United Kingdom
20 participants
n=20 Participants

PRIMARY outcome

Timeframe: 6 months circa

Volunteer holds the device and breathes through the mouthpiece normally for a maximum of 5 minutes.

Outcome measures

Outcome measures
Measure
Exhaled Breath Measurement
n=20 Participants
Patient Exhales into the device Measurement of inhaled measuring hydrogen peroxide in exhaled breath: Participant exhales from device
Hydrogen Peroxide in Exhaled Breath Condensate
0.101 µM
Standard Deviation 0.110

Adverse Events

Healthy Volunteers

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Prof. Omar Usmani

Imperial College London, National Heart & Lung Institute and RBH

Phone: 02073518053

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place