Comparison of Two Different Pupillometer

NCT ID: NCT05717244

Last Updated: 2024-06-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

100 participants

Study Classification

OBSERVATIONAL

Study Start Date

2023-09-01

Study Completion Date

2024-02-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

With the development of refractive surgery, the size of scotopic pupil has been widely concerned by clinicians. Historically, the measurement of pupil size included the use of a pupil ruler, which is known for its drawback of being very subjective and lacking precision. While infrared pupillometry devices such as OPD-Scan III and Sirius are available for accurately and reliably measuring pupil size. Nevertheless, the aforementioned equipments are costly and cumbersome to move in terms of screening and field trial logistics settings. And 2WIN-S is a portable refractor, it can in a short period of diopter and scotopic pupil size and other data obtained at the same time. Therefore, the aim of this study was to compare the agreement between 2WIN-S and OPD-Scan III in measuring scotopic pupil size and the repeatability of 2WIN-S.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Pupil diameter is a parameter of great interest in understanding brain systems and modern refractive surgery. Pupillometry, the measurement of variations in pupil dilation, has offered encouraging evidence for the involvement of disturbed reactivity in depression risk, according to studies. According to research, the pupil dilates in reaction to stimuli requiring a larger cognitive load or a greater emotional intensity. Importantly, studies have related pupil size variations to brain activity in regions associated with emotion regulation, including the dorsolateral prefrontal cortex (DPFC) and the agenesis of the corpus callosum (ACC) . Thus, pupillometry is proposed as a viable peripheral gauge for a variety of brain systems involved in the processing of emotional information.

Some of the postoperative complaints of patients having refractive corneal or lens surgery are related to visual quality and are associated with large pupils since optical aberrations become more dominant when the pupil dilates . If the pupil size exceeds the optical zone size, a marked increase in higher-order aberrations could be observed. Patients might complain about poor contrast sensitivity, increased glare disability, or halos. Precise measurement of scotopic pupil diameter has therefore become an essential step in the preoperative evaluation of patients suitable for refractive surgery and is an important inclusion or exclusion criterion.

This study aimed to assess the agreement and reproducibility of scotopic pupil size measurements using 2WIN-S compared with OPD-Scan III in Chinese adults.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Measurement of Pupil Diameter

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

2WIN-S

Determining pupil diameter by 2WIN-S

Intervention Type DEVICE

OPD

Determining pupil diameter by OPD

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* \>18 years old
* signed informed consent
* willing to participate in the study
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

He Eye Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Emmanuel E Pazo, MD, PhD

Role: STUDY_CHAIR

He Eye Hospital, Shenyang, China

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

He Eye Hospital

Shenyang, Liaoning, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

References

Explore related publications, articles, or registry entries linked to this study.

Jones NP, Siegle GJ, Mandell D. Motivational and emotional influences on cognitive control in depression: A pupillometry study. Cogn Affect Behav Neurosci. 2015 Jun;15(2):263-75. doi: 10.3758/s13415-014-0323-6.

Reference Type BACKGROUND
PMID: 25280561 (View on PubMed)

Siegle GJ, Steinhauer SR, Friedman ES, Thompson WS, Thase ME. Remission prognosis for cognitive therapy for recurrent depression using the pupil: utility and neural correlates. Biol Psychiatry. 2011 Apr 15;69(8):726-33. doi: 10.1016/j.biopsych.2010.12.041.

Reference Type BACKGROUND
PMID: 21447417 (View on PubMed)

Siegle GJ, Granholm E, Ingram RE, Matt GE. Pupillary and reaction time measures of sustained processing of negative information in depression. Biol Psychiatry. 2001 Apr 1;49(7):624-36. doi: 10.1016/s0006-3223(00)01024-6.

Reference Type BACKGROUND
PMID: 11297720 (View on PubMed)

Siegle GJ, Steinhauer SR, Stenger VA, Konecky R, Carter CS. Use of concurrent pupil dilation assessment to inform interpretation and analysis of fMRI data. Neuroimage. 2003 Sep;20(1):114-24. doi: 10.1016/s1053-8119(03)00298-2.

Reference Type BACKGROUND
PMID: 14527574 (View on PubMed)

Critchley HD, Tang J, Glaser D, Butterworth B, Dolan RJ. Anterior cingulate activity during error and autonomic response. Neuroimage. 2005 Oct 1;27(4):885-95. doi: 10.1016/j.neuroimage.2005.05.047.

Reference Type BACKGROUND
PMID: 15996878 (View on PubMed)

Urry HL, van Reekum CM, Johnstone T, Kalin NH, Thurow ME, Schaefer HS, Jackson CA, Frye CJ, Greischar LL, Alexander AL, Davidson RJ. Amygdala and ventromedial prefrontal cortex are inversely coupled during regulation of negative affect and predict the diurnal pattern of cortisol secretion among older adults. J Neurosci. 2006 Apr 19;26(16):4415-25. doi: 10.1523/JNEUROSCI.3215-05.2006.

Reference Type BACKGROUND
PMID: 16624961 (View on PubMed)

Fardell J. Poverty and infant deaths. Nurs Times. 1989 Jan 11-17;85(2):18. No abstract available.

Reference Type BACKGROUND
PMID: 2922323 (View on PubMed)

Martinez CE, Applegate RA, Klyce SD, McDonald MB, Medina JP, Howland HC. Effect of pupillary dilation on corneal optical aberrations after photorefractive keratectomy. Arch Ophthalmol. 1998 Aug;116(8):1053-62. doi: 10.1001/archopht.116.8.1053.

Reference Type BACKGROUND
PMID: 9715686 (View on PubMed)

Rosen ES, Gore CL, Taylor D, Chitkara D, Howes F, Kowalewski E. Use of a digital infrared pupillometer to assess patient suitability for refractive surgery. J Cataract Refract Surg. 2002 Aug;28(8):1433-8. doi: 10.1016/s0886-3350(01)01350-5.

Reference Type BACKGROUND
PMID: 12160815 (View on PubMed)

Liu Q, Yang X, Lin L, Liu M, Lin H, Liu F, Xie Y, Lam DSC. Review on Centration, Astigmatic Axis Alignment, Pupil Size and Optical Zone in SMILE. Asia Pac J Ophthalmol (Phila). 2019 Sep-Oct;8(5):385-390. doi: 10.1097/01.APO.0000580144.22353.46.

Reference Type BACKGROUND
PMID: 31567265 (View on PubMed)

Couret D, Boumaza D, Grisotto C, Triglia T, Pellegrini L, Ocquidant P, Bruder NJ, Velly LJ. Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study. Crit Care. 2016 Mar 13;20:99. doi: 10.1186/s13054-016-1239-z.

Reference Type BACKGROUND
PMID: 27072310 (View on PubMed)

Nyholm B, Obling L, Hassager C, Grand J, Moller J, Othman M, Kondziella D, Kjaergaard J. Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients. PLoS One. 2022 Jul 28;17(7):e0272303. doi: 10.1371/journal.pone.0272303. eCollection 2022.

Reference Type BACKGROUND
PMID: 35901103 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2WIN2023

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.