Refractix DSP and TS Meter-DSP Measurement Comparison

NCT ID: NCT05717036

Last Updated: 2023-02-08

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

36 participants

Study Classification

OBSERVATIONAL

Study Start Date

2023-02-13

Study Completion Date

2023-02-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this clinical trial is to compare the serum plasma measurement results between the FDA cleared TS Meter-DSP and investigational Refractix DSP. Study participants will be individuals being screened for plasma donation in a plasmaphereris center. The main question the study aims to answer is whether the measurement taken on the investigational Refractix DSP device is equivalent, defined as within +/- 0.3g/100ml, of the measurement taken on the TS Meter-DSP. Participants will be asked to provide a second capillary tube of blood (\<0.085ml) from the fingerstick that is part of their routine pre-screening for plasma donation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The TS Meter-DSP and investigational Refractix DSP are digital refractometers intended for the quantitative measurement of total protein in human serum or plasma. The devices are intended for use in plasma collection centers and are not for diagnostic purposes. Serum/plasma samples are taken from a successful microhematocrit assay and dispensed via pipette on to the instruments. The instruments measure the temperature compensated refractive index of the serum or plasma sample and digitally convert refractive index to an accurate total protein value. Potential donors with a total protein level of between 6.0 g/100ml and 9.0 g/100ml and that meet other pre-screening requirements are permitted to donate plasma.

These devices are FDA Class I in vitro diagnostic devices; FDA Regulation Number 862.2800 Refractometer for clinical use; with Product Code PSM, Refractometer for Donor Testing.

Participants will be those presenting for plasma donation. Ordinary pre-screening for plasma donation includes a fingerstick and the collection of one small capillary tube (\<0.085ml) of blood. Participants who have consented to this study will be asked to supply a second capillary tube (\<0.085ml) of blood for the clinical trial. The two samples will be centrifuged and hematocrit measured per the plasma center's standard operating procedures. One sample will be dispensed onto the TS Meter-DSP for total protein measurement. This measurement will be used to determine the individual's eligibility to donate plasma. The second sample will be dispensed on to the investigational Refractix DSP for total protein measurement. The measurements from both devices will be recorded on the Case Report Form. The study requires (36) participants with total protein measurements between 6.0 g/100ml and 9.0 g/100ml.

The primary analysis of data will include:

1. a Grubb's test for outlying paired difference values will be performed. If outliers are detected and a plausible non-device failure mechanism can be identified (eg, operator or data entry error), the values will be excluded from the acceptance criterion calculations;
2. an alpha=0.05 level equivalence test with an equivalence interval of +/- 0.3 g/100ml will be performed using the TOST (Two One Sample Test) procedure. A paired t-test 90% confidence interval for the difference in paired sample measurements will be constructed and reported; and
3. calculate the percentage of measurement pairs falling outside of the +/-0.3 tolerance.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

TS Meter-DSP Measurement and Refractix DSP Measurement

The study will involve blood serum samples from (36) participants. Participants will be those presenting at a plasma collection center for routine plasma donation. Ordinary pre-screening for plasma donation includes a fingerstick and the collection of one small capillary tube (\<0.085ml) of blood. Participants will be asked to provide a second capillary tube (\<0.085ml) of blood from this fingerstick.

Serum Total Protein Measurement with TS Meter-DSP and Refractix DSP

Intervention Type DEVICE

The two blood samples will be centrifuged and hematocrit measured per the plasma center's standard operating procedures. One participant sample will be dispensed onto the cleared TS Meter-DSP for a serum total protein measurement. This measurement will be used, along with other pre-screening information, to determine if the participant can donate plasma. The second participant sample will be dispensed onto the investigational Refractix DSP for a serum total protein measurement. It will be compared to the sample measurement taken on the cleared TS Meter-DSP.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Serum Total Protein Measurement with TS Meter-DSP and Refractix DSP

The two blood samples will be centrifuged and hematocrit measured per the plasma center's standard operating procedures. One participant sample will be dispensed onto the cleared TS Meter-DSP for a serum total protein measurement. This measurement will be used, along with other pre-screening information, to determine if the participant can donate plasma. The second participant sample will be dispensed onto the investigational Refractix DSP for a serum total protein measurement. It will be compared to the sample measurement taken on the cleared TS Meter-DSP.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subjects must be between the ages of 18 and 90 years old
* Subjects must be able and willing to provide signed informed consent
* Subjects must be able to follow study instructions

Exclusion Criteria

* Insufficient amount of plasma sample for use on either device in the study.
* Plasma samples of with total protein measurements outside of the 6.0 g/100ml to 9.0 g/100ml range will be excluded from the data analysis.
Minimum Eligible Age

18 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Reichert, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hemarus Plasma

Lauderhill, Florida, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Linton Davis

Role: CONTACT

754-336-1503

Melvyn W Kramer, MD

Role: CONTACT

978-333-1997

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Linton W Davis

Role: primary

754-336-1503

Melvyn W Kramer, MD

Role: backup

9783331997

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

13910000-TPR-30

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

TRIP-Patch vs the Rigiscan
NCT05219071 COMPLETED
Wetness Sensing System
NCT05454813 COMPLETED NA