Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Rapid Panel Professional Use Device and the Panbio™ COVID-19/Flu A&B Rapid Panel Self-Test Device
NCT ID: NCT05715515
Last Updated: 2023-11-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
903 participants
INTERVENTIONAL
2023-01-06
2023-05-29
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This study is part of the performance evaluation to support the CE conformity assessment procedures.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Evaluation of the Panbio™ COVID-19/Flu A&B Panel
NCT06127108
Evaluation of a COVID-19 Rapid Diagnostic Test in ER Departments in Mexico: a Multi-center Study
NCT04894760
Performance Evaluation of the LumiraDX SARS-CoV-2 Ag Ultra and LumiraDX SARS-CoV-2 & Flu A/B Tests at Point of Care (POC) Sites
NCT05728970
Clinical Feasibility of the BinaxNOW™ COVID-19/Flu A&B Combo in the Southern Hemisphere
NCT06928129
Prospective Clinical Evaluation of the FilmArray Respiratory Panel 2
NCT03012217
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
After obtaining written informed consent, a study-specific subject identification number (ID) will be assigned to the subject. All eligible subjects will be assigned to both Professional Use arm and the Self-Test arm of the study. Subject demographics and a brief medical history will be collected.
Lay users (self-tester or caregiver) will first collect one mid-turbinate nasal swab from both nostrils, and perform and interpret the Panbio™ Rapid Panel ST device, under the observation of a trained observer. All procedures for testing and result interpretation, including sample collection and extraction, will be conducted following the IFU provided in the kit. Each Panbio™ Rapid Panel ST result will be interpreted firstly by the lay user and followed immediately by the observer who will also photograph the test at the time of interpretation. Each lay user will fill out a user evaluation questionnaire, and a study staff member will complete an observer questionnaire for each lay user. A minimum of 100 lay users will also read mock device tests presented by a study staff member. Mock devices (simulated to represent testing results) will be used for usability testing (result interpretation).
A study staff member will then collect two NP swabs (one swab from each nostril) from all subjects. The first NP swab sample will be used to conduct a Panbio™ Rapid Panel PU test, following the IFU. The test result will be photographed at the time of result interpretation. Each study staff member who performs a Panbio™ Rapid Panel PU test will fill out a user evaluation questionnaire once, to assess the usability of the device.
The second NP swab sample will be eluted in Universal Transport Medium (UTM) provided by Abbott/the Core Laboratory, labelled and stored, according to the laboratory manual. UTM samples will be shipped to the Core Laboratory for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2, according to the laboratory manual.
Each subject's demographic information, education, symptomology data, test results and questionnaires, where relevant, will be recorded on source documentation and transferred to an Electronic Data Capture system.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Nasal sampling/Testing (Self-Test) + Nasopharyngeal sampling/Testing (Professional Use)
Lay users (self-tester or caregiver) will be provided with a Panbio™ COVID-19/Flu A\&B Rapid Panel Self-Test kit. Each lay user will collect one mid-turbinate nasal swab from both nostrils, perform and interpret the Panbio™ COVID-19/Flu A\&B Rapid Panel Self-Test. All procedures for testing and result interpretation, including sample collection and extraction will be conducted by the lay user following the Instructions for Use provided in the kit.
The first NP swab sample will be used to conduct a Panbio™ COVID- 19/FluA\&B Rapid Panel Professional Use test.
The second NP swab sample will be eluted in Universal Transport Medium (UTM) provided by Abbott/the Core Laboratory, labelled and stored, according to the laboratory manual. UTM samples will be shipped to the Core Laboratory for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2, according to the laboratory manual.
Panbio™
The Panbio™ COVID-19/Flu A\&B Rapid Panel Professional use device is a visual lateral flow assay, for rapid immunochromatographic qualitative detection of COVID-19 antigen, Influenza A antigen and Influenza B antigen in nasopharyngeal swabs, collected by a trained health worker.
The Panbio™ COVID-19/Flu A\&B Rapid Panel Self-Test device is a visual lateral flow assay, for rapid immunochromatographic qualitative detection of COVID-19 antigen, Influenza A antigen and Influenza B antigen in self-collected mid-turbinate nasal swabs. The test is designed to be used by lay users
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Panbio™
The Panbio™ COVID-19/Flu A\&B Rapid Panel Professional use device is a visual lateral flow assay, for rapid immunochromatographic qualitative detection of COVID-19 antigen, Influenza A antigen and Influenza B antigen in nasopharyngeal swabs, collected by a trained health worker.
The Panbio™ COVID-19/Flu A\&B Rapid Panel Self-Test device is a visual lateral flow assay, for rapid immunochromatographic qualitative detection of COVID-19 antigen, Influenza A antigen and Influenza B antigen in self-collected mid-turbinate nasal swabs. The test is designed to be used by lay users
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Subject has active nose bleeds or acute facial injuries/trauma.
* Subject has received a nasal vaccine (i.e., FluMist®) within the previous fourteen (14) days.
* Subject is currently taking or has taken an antiviral medication- e.g., Amantadine, Rimantadine, Relenza® (Zanamivir), Tamiflu® (Oseltamivir Phosphate), and Flumadine®-for influenza or COVID-19 within the previous thirty (30) days.
* Subject is currently enrolled in a study to evaluate an investigational drug.
* Self-tester or caregiver has prior medical or laboratory training.
* Self-tester or caregiver has a visual impairment that cannot be restored using glasses or contact lenses or lay user is unable to read the Instructions for Use.
* Subject has a condition deemed unfit to safely perform the test.
* Subject is unwilling or unable to provide informed consent.
* Vulnerable populations as deemed inappropriate for the study by the site's PI.
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Abbott Rapid Dx
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UCCT @ AFC Urgent Care- Easley
Easley, South Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SDRD-H-029-P
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.