Trial Outcomes & Findings for HFOV With Intermittent Sigh Breaths in Neonate: Carbon Dioxide Level (NCT NCT05682937)
NCT ID: NCT05682937
Last Updated: 2025-02-21
Results Overview
ABL800 BASIC (Radiometer Medical ApS™, Denmark) analyzed all blood gas samples within 1 min after collection. The blood gas machine was auto-calibrated every 4 h by trained specialists every day.
TERMINATED
NA
30 participants
before sigh (baseline) and after sigh (2 hours)
2025-02-21
Participant Flow
Ninety-four infants were assessed for eligibility; 64 were excluded because of previous or current pulmonary air leaks (n = 3), heterogeneous lung diseases (n = 7), suspected or confirmed grade III-IV intraventricular hemorrhage (n = 1), hemodynamic instability despite using an inotrope (n = 15), PaCO2 level \< 45 or \> 70 mm Hg before intervention (n = 30), moribund status (n = 7), and parents' decision not to participate (n = 1). Thirty participants were finally enrolled.
Participant milestones
| Measure |
HFOV-sigh Mode
HFOV-sigh setting both SLE6000 and Drager Babylog VN500: setting (Hz, MAP, delta pressure) same as HFOV, set sigh RR 3 breath/min, Sigh Ti = 1 sec, Sigh PIP = (MAP+5, maximum 30) cm H2O, Slope sigh 0.5.
|
|---|---|
|
Overall Study
STARTED
|
30
|
|
Overall Study
COMPLETED
|
30
|
|
Overall Study
NOT COMPLETED
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
HFOV With Intermittent Sigh Breaths in Neonate: Carbon Dioxide Level
Baseline characteristics by cohort
| Measure |
HFOV-sigh Mode
n=30 Participants
HFOV-sigh setting both SLE6000 and Drager Babylog VN500: setting (Hz, MAP, delta pressure) same as HFOV, set sigh RR 3 breath/min, Sigh Ti = 1 sec, Sigh PIP = (MAP+5, maximum 30) cm H2O, Slope sigh 0.5.
|
|---|---|
|
Age, Continuous
|
1.88 day
n=5 Participants
|
|
Sex: Female, Male
Female
|
13 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
17 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
30 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Gestational age
|
33.6 weeks
STANDARD_DEVIATION 4.1 • n=5 Participants
|
|
Birth weight
|
2305 grams
STANDARD_DEVIATION 853 • n=5 Participants
|
PRIMARY outcome
Timeframe: before sigh (baseline) and after sigh (2 hours)ABL800 BASIC (Radiometer Medical ApS™, Denmark) analyzed all blood gas samples within 1 min after collection. The blood gas machine was auto-calibrated every 4 h by trained specialists every day.
Outcome measures
| Measure |
HFOV-sigh Mode
n=30 Participants
HFOV-sigh setting both SLE6000 and Drager Babylog VN500: setting (Hz, MAP, delta pressure) same as HFOV, set sigh RR 3 breath/min, Sigh Ti = 1 sec, Sigh PIP = (MAP+5, maximum 30) cm H2O, Slope sigh 0.5.
|
|---|---|
|
Arterial pCO2 Level
HFOV before sigh
|
48.8 mm Hg
Standard Deviation 3.1
|
|
Arterial pCO2 Level
HFOV after sigh
|
45.2 mm Hg
Standard Deviation 6.6
|
SECONDARY outcome
Timeframe: before sigh (baseline) and after sigh (2 hours)Population: oxygen index = mean airway pressure x FiO2 / PaO2
oxygen index (oxygen index = mean airway pressure x FiO2 / PaO2), higher scores mean a worse outcome, no unit of scale.
Outcome measures
| Measure |
HFOV-sigh Mode
n=30 Participants
HFOV-sigh setting both SLE6000 and Drager Babylog VN500: setting (Hz, MAP, delta pressure) same as HFOV, set sigh RR 3 breath/min, Sigh Ti = 1 sec, Sigh PIP = (MAP+5, maximum 30) cm H2O, Slope sigh 0.5.
|
|---|---|
|
Oxygenation
HFOV after sigh
|
2.95 no unit
Interval 2.37 to 3.83
|
|
Oxygenation
HFOV before sigh
|
3.06 no unit
Interval 2.48 to 4.26
|
SECONDARY outcome
Timeframe: 2 hours after sigh breathsPopulation: the frequency of each MAP level was presented by the count of participants
Mean Airway Pressure (MAP), cmH2O
Outcome measures
| Measure |
HFOV-sigh Mode
n=30 Participants
HFOV-sigh setting both SLE6000 and Drager Babylog VN500: setting (Hz, MAP, delta pressure) same as HFOV, set sigh RR 3 breath/min, Sigh Ti = 1 sec, Sigh PIP = (MAP+5, maximum 30) cm H2O, Slope sigh 0.5.
|
|---|---|
|
Mean Airway Pressure
MAP = 7 cmH2O
|
5 Participants
|
|
Mean Airway Pressure
MAP = 8 cmH2O
|
12 Participants
|
|
Mean Airway Pressure
MAP = 9 cmH2O
|
8 Participants
|
|
Mean Airway Pressure
MAP = 10 cmH2O
|
4 Participants
|
|
Mean Airway Pressure
MAP = 13 cmH2O
|
1 Participants
|
Adverse Events
HFOV-sigh Mode
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place