SpO2 Comparison Between Commercial Smartwatch and Medical-grade Pulse Oximeter During Hypoxia
NCT ID: NCT05657288
Last Updated: 2023-03-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
40 participants
INTERVENTIONAL
2022-12-28
2023-12-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
SpO2 Difference Between Fingers of the Hand During Sequential Desaturation and Step Resaturation
NCT05681637
Comparison of Perfusion Index Monitoring Using a Smartwatch and a Pulse Oximeter
NCT06626217
Variability of SpO2 Measurements Depending on the Choice of Finger for Sensor Placement
NCT04771663
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT02571686
Pulse Oximeter Hypoxia
NCT04562584
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Hypoxia
Volunteers sequentially inhale three hypoxic gas mixtures each for 2.5 minute. Every measurement will begin with a two-minute stabilization phase, during which the physiological values of the volunteer will be checked. During the whole experiment, non-invasive SpO2 measurements will be performed on the middle finger and on the wrist of left hand.
Breathing mixtures of O2 and N2 and monitoring SpO2 on finger and left wrist
Volunteers sequentially inhale three hypoxic gas mixtures each for 2.5 minute. Every measurement will begin with a two-minute stabilization phase, during which the physiological values of the volunteer will be checked. During the whole experiment, non-invasive SpO2 measurements will be performed on the middle finger and on the wrist of left hand.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Breathing mixtures of O2 and N2 and monitoring SpO2 on finger and left wrist
Volunteers sequentially inhale three hypoxic gas mixtures each for 2.5 minute. Every measurement will begin with a two-minute stabilization phase, during which the physiological values of the volunteer will be checked. During the whole experiment, non-invasive SpO2 measurements will be performed on the middle finger and on the wrist of left hand.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* severe cardiovascular conditions
* severe asthma or other severe respiratory conditions
* injury to the upper limbs or hands that could affect the peripheral perfusion
* diabetes
* hypotension or hypertension
18 Years
60 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Czech Technical University in Prague
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Simon Walzel, MSc.
Role: PRINCIPAL_INVESTIGATOR
Czech Technical University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Czech Technical University in Prague
Kladno, , Czechia
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Rafl J, Bachman TE, Rafl-Huttova V, Walzel S, Rozanek M. Commercial smartwatch with pulse oximeter detects short-time hypoxemia as well as standard medical-grade device: Validation study. Digit Health. 2022 Oct 11;8:20552076221132127. doi: 10.1177/20552076221132127. eCollection 2022 Jan-Dec.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
NVT02/2022
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.