Comparison of the Removal of Uremic Toxins With Medium Cut-off and Super High-flux Vitamin E-coated Dialyzers
NCT ID: NCT05610683
Last Updated: 2024-04-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
41 participants
INTERVENTIONAL
2023-06-14
2024-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Specific complications have been associated with the accumulation of middle-size toxins, including beta2-microglobulin (12 kDa), myoglobin (17 kDa), prolactin (23 kDa), alpha1-microglobulin (33 kDa), alpha1-glycoprotein (44 kDa), kappa (22 kDa) and lambda (45 kDa) free light chains (FLC). Moreover, mediators of oxidative stress such as asymmetric dimethylarginine, malondialdehyde, oxidative-LDL and inflammatory cytokines such as Interleukin-6 (IL)-6, IL1-β, TNF-α have been involved in atherosclerosis, malnutrition, cardiovascular events and mortality.
Hemodialysis (HD) remains the main standard modality of renal replacement therapy in ESRD. In the past decade, low-flux hemodialysis was most commonly used, providing effective clearance of small solutes through diffusion, but negligible clearance of middle molecules. This limitation was insufficiently improved by the development of high-flux (HF) dialyzers due to their cut-off pores size values of approximately 15-20 kDa. In fact, most of middle molecules cannot be efficiently removed by HF-HD because of their molecular radii larger than that of membrane pores. Thus, HF dialyzers were used in post dilution on-line hemodiafiltration (OL-HDF) mode with high convection volumes and achieved greatest clearance of middle molecules. However, OL-HDF is generally not available in most HD centers and needs additional hardware technology. Therefore, several super high-flux (SHF) dialyzers integrating higher cut-off size pore value and achieving Beta2-microglobulin clearance \> 70 ml/min were developed for HD mode. These SHF dialyzers used in HD (SHF-HD) provides similar middle molecules depuration compared to OL-HDF.
The recently developed medium cut-off (MCO) dialyzer (Theranova 500™, Baxter healthcare Corporation Deerfield, USA; surface area 2 m², ultrafiltration coefficient: 59 ml/h/mmHg) differs from conventional HF membranes by higher and controlled porosity resulting in a steep sieving curve with a cut-off value approaching that of albumin. MCO-HD has demonstrated efficient depuration of middle uremic toxins as compared to HF-HD, similar to that of OL-HDF. MCO-HD and SHF-HD are two new large pore size dialyzers currently used nowadays in HD.
In addition, the interaction between blood and membrane surface play a key role in generating oxidative stress and inflammation. Antioxidants such as vitamin E work by inhibiting LDL oxidation and by limiting cellular response to oxidized LDL. In HD patients, vitamin E may be integrated as a part of the HD procedure in the form of bioreactive dialysis membranes, in which the blood surface has been modified with alpha-tocopherol. Dialysis with vitamin E-coated membranes has been associated with an improvement in biocompatibility including circulating lipid peroxidation biomarkers and cytokine induction. In small studies, vitamin E coated dialyzers have been associated with reduced red blood count fragility and improvements in erythropoietin resistance index and erythropoietin requirements in HD.
VieX (Polysulfone, surface area: 2.1 m², sterilization gamma, ultrafiltration coefficient: 104.3 ml/h/mmHg, Asahi Kasei Medical, Japan), a novel SHF vitamin E-coated (SHVE) dialyzer, which has larger pore size than HF dialyzer, might provide higher middle molecules removal and biocompatibility improvement.
The aim of the present study was to compare the efficiency of the SHFVE dialyzer (VieX™) versus the MCO dialyzer (Theranova 500™) on the removal of beta2-microglobulin and other middle molecules in a non-inferiority fashion, and their respective effects on inflammation, oxidative stress and biocompatibility parameters.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Comparison of Protein-bound and Large Molecular Weight Uremic Toxin Removals With Novel Super High-flux Dialyzer Between Hemodialysis and High Volume Online HDF Modalities
NCT06567483
Expanded Hemodialysis Versus High-Volume Online Hemodiafiltration for Uremic Toxin Removal
NCT07348536
DIALysis With EXpanded Solute Removal
NCT06660277
Influence of the Vitamine E Coated Dialyzer on Inflammation and Anemia
NCT03218865
Evaluation of Biocompatibility and Performances of 4 Dialyzers in Different Mode Treatments
NCT03262272
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
VieX (Polysulfone, surface area: 2.1 m², sterilization gamma, ultrafiltration coefficient: 104.3 ml/h/mmHg, Asahi Kasei Medical, Japan), a novel SHF vitamin E-coated dialyzer, which has larger pore size than HF dialyzer, might provide also higher middle molecules removal and more biocompatibility improvement.
Preliminary data demonstrate similar reduction ration of beta2-microglobulin, which is the most studied middle molecule, between MCO-HD and Super High Flux Vitamin E (SHFVE)-HD.
The aim of the present study was to compare the efficiency of the SHFVE dialyzer versus the MCO dialyzer on the removal of beta2-microglobulin and other middle molecules in a non-inferiority fashion, and their respective effects on inflammation, oxidative stress and biocompatibility parameters.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
SHFVE-HD group
Hemodialysis sessions using the VieX™ (Polysulfone, surface area: 2.1 m², sterilization gamma, ultrafiltration coefficient: 104.3 ml/h/mmHg, Asahi Kasei Medical, Japan).
Hemodialysis sessions using SHFVE dialyzer (VieX™) or the MCO (Theranova 500™) dialyzer
Patients will receive thrice weekly 4 hours hemodialysis sessions during 3 months
MCO-HD group
Hemodialysis sessions using the Theranova 500™ (Baxter healthcare Corporation Deerfield, USA; surface area 2 m², ultrafiltration coefficient: 59 ml/h/mmHg).
Hemodialysis sessions using SHFVE dialyzer (VieX™) or the MCO (Theranova 500™) dialyzer
Patients will receive thrice weekly 4 hours hemodialysis sessions during 3 months
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hemodialysis sessions using SHFVE dialyzer (VieX™) or the MCO (Theranova 500™) dialyzer
Patients will receive thrice weekly 4 hours hemodialysis sessions during 3 months
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age ≥ 18 years
* Patients established on HF-HD trice weekly four hour-sessions for at least 3 months
Exclusion Criteria
* Pregnant or breast feeding women
* Any uncontrolled medical condition, psychiatric disorder or biological abnormality that might interfere with subject's participation or ability to sign an informed consent.
* Significant residual kidney function as defined by an urine output \> 500 mL.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hemotech
INDUSTRY
Poitiers University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
CHU de Poitiers
Poitiers, , France
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Belmouaz M, Cogne E, Joly F, Duthe F, Desport E, Martin C, Hauet T, Giraud S, Lemarie E, Durocher L, Bridoux F. Effects of super high-flux vitamin E-coated and medium cut-off dialyzers on uremic toxins removal and biocompatibility: the E-FLUX randomized controlled study. Clin Kidney J. 2025 Apr 11;18(5):sfaf106. doi: 10.1093/ckj/sfaf106. eCollection 2025 May.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
E-FLUX
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.