Efficacy and Safety of Pulmonary Function Analysis With Dynamic Digital Radiography Total Respiratory Cycle Photography

NCT ID: NCT05565027

Last Updated: 2022-10-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-10-20

Study Completion Date

2023-10-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The digital X-ray system produced by Shenzhen Angell Technology Co., Ltd was selected as the tested equipment, and the powerlab biological signal acquisition and analysis system equipped with a pneumotachograph by ADInstruments was selected as the reference equipment. During the study, the lung volume measurements obtained by the lung function analysis method based on the dynamic digital radiography full respiratory cycle photography of the tested equipment was compared with the lung volume measurements obtained by the reference device pneumotachograph. The consistency of the lung volume measurements was used as the main validity evaluation index to observe the distribution of the differences between the measured values of the test device and the reference device, and to verify the validity of the declared product according to the main validity evaluation index.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Pulmonary function test is a test to explore the functional status of human respiratory system with the knowledge of exercise respiratory physiology and modern examination technology. It is an important test content for clinical diagnosis, severity assessment, treatment and prognosis assessment of chest and lung diseases, which has been widely used in the fields of respiratory medicine, surgery and anesthesiology. Compared with chest X-rays and CT examinations, which reflect the static function of the chest and lungs, pulmonary function tests can better reflect the dynamic functional changes of the body.

However, pulmonary function test is not well performed to assess the functional status in patients with poor cooperation (e.g., poor lung function, inability to understand cooperation). Dynamic digital X-ray whole respiratory cycle photography uses advanced dynamic radiography and acquisition technology to obtain high-definition dynamic lung images during the whole respiratory cycle of the patient, and uses the industry's first rotating foot pedal to rotate the patient to obtain weighted 3D scan data and single-angle or multi-angle lung data. The patient's lung function is analyzed by algorithmically extracting the patient's full respiratory cycle airway nodes and branches and data statistics. For patients who cannot cooperate with the lung function, it can provid information on the dynamic function of the patient's chest and lungs for doctors to further improve clinical diagnosis and treatment.

At present, the digital X-ray system (DTP580B-3) and the patient position fixation frame MRW-P1 manufactured by Shenzhen Angell Technology Co., Ltd. have passed the inspection by the inspection agency certified by the State Drug Administration of China (NMPA). Clinical trials were conducted to further evaluate the clinical effectiveness and safety of the products.

The lung volume was measured using a pneumotachograph (with a physiological signal recorder) and a digital X-ray system (UC dynamic DR) in the same healthy subject, and the lung volume values measured by each of the reference device were analyzed for consistency to evaluate the validity of the lung volume measurement by the test device. And To evaluate the safety of the lung volume measurement function of the test device in clinical use based on the occurrence of device malfunctions, adverse events and serious adverse events in the trial.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy Volunteers

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

The subject stood on the turntable of the instrument and grasped the postural fixator with both hands up. The subjects pinched their nose and breathed through the disposable filter mouthpiece connected to the pneumotachograph, taking care not to leak air at the corners of the mouth. The subjects were instructed to perform tidal breathing, deep inhalation, deep exhalation, etc., and to perform dynamic DR photography and pneumotachograph monitoring simultaneously. At the end of the examination, assist the subjects to leave the examination equipment and re-measure their vital signs.
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Lung volume measurements using the test and reference devices were clearly different and could not be blinded to subjects and investigators, so an open trial design was used.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pneumotachograph

The subject stood on the turntable of the instrument and grasped the postural fixator with both hands up. The subjects pinched their nose and breathed through the disposable filter mouthpiece connected to the pneumotachograph, taking care not to leak air at the corners of the mouth. The subjects were instructed to perform tidal breathing, deep inhalation, deep exhalation, etc., and to monitor lung volume by pneumotachograph.

Group Type ACTIVE_COMPARATOR

Pneumotachograph

Intervention Type DEVICE

The pneumotachograph monitors the flow rate, and the lung volume is calculated by integrating.

Dynamic digital radiography

The subject stood on the turntable of the instrument and grasped the postural fixator with both hands up. The subjects pinched their nose and breathed through the disposable filter mouthpiece connected to the pneumotachograph, taking care not to leak air at the corners of the mouth. The subjects were instructed to perform tidal breathing, deep inhalation, deep exhalation, etc., and to monitor lung volume by dynamic digital radiography analysis.

Group Type EXPERIMENTAL

Dynamic digital radiography

Intervention Type DEVICE

The use of advanced dynamic X-ray photography and acquisition technology can obtain high-definition dynamic lung images of patients throughout the respiratory cycle for analysis.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Dynamic digital radiography

The use of advanced dynamic X-ray photography and acquisition technology can obtain high-definition dynamic lung images of patients throughout the respiratory cycle for analysis.

Intervention Type DEVICE

Pneumotachograph

The pneumotachograph monitors the flow rate, and the lung volume is calculated by integrating.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

① age ≥ 18 years; ② subjects willing to undergo chest radiography; ③ normal pulmonary ventilation function (forced vital capacity (FVC) ≥ 80% of the expected value; forced expiratory volume in first second (FEV1) ≥ 80% of the expected value; 1 second rate (FEV1/FVC) ≥ 70%); ④ can perform tidal breathing, deep inspiration and deep expiration; ⑤ no history of smoking; ⑥ no history of chronic respiratory disease; ⑦ no acute respiratory disease within 4 weeks; ⑧ subjects willing to provide written informed consent

Exclusion Criteria

① Pregnant and lactating women; ② Inability to stand alone; ③ Severe vertigo and other adverse reactions to rotation in place.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Shenzhen People's Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Rongchang Chen, PhD

Role: STUDY_CHAIR

Shenzhen People's Hospital

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Jianyi Niu, MD

Role: CONTACT

+8617825846046

Lili Guan, PhD

Role: CONTACT

+8617825846046

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

202101-02

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

LDCT Screening in Non-smokers in Taiwan
NCT02611570 ACTIVE_NOT_RECRUITING