Efficacy and Safety of Pulmonary Function Analysis With Dynamic Digital Radiography Total Respiratory Cycle Photography
NCT ID: NCT05565027
Last Updated: 2022-10-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
20 participants
INTERVENTIONAL
2022-10-20
2023-10-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Exploring the Diagnostic Performance of Dynamic Chest Radiology in Chronic Obstructive Pulmonary Disease
NCT06653413
Pulmonary Ventilation/Perfusion Imaging for the Prediction of Postoperative Residual Pulmonary Function
NCT03357094
Early Stage Lung Cancer Screening With Low-dose Computed Tomographic
NCT02898441
Decoding the Association of Imaging and Tumor Microenvironment in Lung Cancer Using Radiogenomic Approach(Radiogenomics-Lung)
NCT06500312
Using Imaging and Molecular Markers to Predict Tumor Response and Lung Toxicity in Lung Cancer
NCT00603057
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
However, pulmonary function test is not well performed to assess the functional status in patients with poor cooperation (e.g., poor lung function, inability to understand cooperation). Dynamic digital X-ray whole respiratory cycle photography uses advanced dynamic radiography and acquisition technology to obtain high-definition dynamic lung images during the whole respiratory cycle of the patient, and uses the industry's first rotating foot pedal to rotate the patient to obtain weighted 3D scan data and single-angle or multi-angle lung data. The patient's lung function is analyzed by algorithmically extracting the patient's full respiratory cycle airway nodes and branches and data statistics. For patients who cannot cooperate with the lung function, it can provid information on the dynamic function of the patient's chest and lungs for doctors to further improve clinical diagnosis and treatment.
At present, the digital X-ray system (DTP580B-3) and the patient position fixation frame MRW-P1 manufactured by Shenzhen Angell Technology Co., Ltd. have passed the inspection by the inspection agency certified by the State Drug Administration of China (NMPA). Clinical trials were conducted to further evaluate the clinical effectiveness and safety of the products.
The lung volume was measured using a pneumotachograph (with a physiological signal recorder) and a digital X-ray system (UC dynamic DR) in the same healthy subject, and the lung volume values measured by each of the reference device were analyzed for consistency to evaluate the validity of the lung volume measurement by the test device. And To evaluate the safety of the lung volume measurement function of the test device in clinical use based on the occurrence of device malfunctions, adverse events and serious adverse events in the trial.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pneumotachograph
The subject stood on the turntable of the instrument and grasped the postural fixator with both hands up. The subjects pinched their nose and breathed through the disposable filter mouthpiece connected to the pneumotachograph, taking care not to leak air at the corners of the mouth. The subjects were instructed to perform tidal breathing, deep inhalation, deep exhalation, etc., and to monitor lung volume by pneumotachograph.
Pneumotachograph
The pneumotachograph monitors the flow rate, and the lung volume is calculated by integrating.
Dynamic digital radiography
The subject stood on the turntable of the instrument and grasped the postural fixator with both hands up. The subjects pinched their nose and breathed through the disposable filter mouthpiece connected to the pneumotachograph, taking care not to leak air at the corners of the mouth. The subjects were instructed to perform tidal breathing, deep inhalation, deep exhalation, etc., and to monitor lung volume by dynamic digital radiography analysis.
Dynamic digital radiography
The use of advanced dynamic X-ray photography and acquisition technology can obtain high-definition dynamic lung images of patients throughout the respiratory cycle for analysis.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Dynamic digital radiography
The use of advanced dynamic X-ray photography and acquisition technology can obtain high-definition dynamic lung images of patients throughout the respiratory cycle for analysis.
Pneumotachograph
The pneumotachograph monitors the flow rate, and the lung volume is calculated by integrating.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shenzhen People's Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Rongchang Chen, PhD
Role: STUDY_CHAIR
Shenzhen People's Hospital
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
202101-02
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.