Characterisation of Biofilm Growth on Coated vs. Uncoated Urinary Catheter Surfaces in Normal Clinical Use
NCT ID: NCT05513677
Last Updated: 2022-08-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
35 participants
INTERVENTIONAL
2018-08-14
2021-12-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Selection follows documented hospital protocols for routine catheterisation
2. Measured Patients: 30 patients (Convenience sample: non-blinded and non-randomised)
* 20 who receive the M4D coated catheter.
* 10 who receive the standard uncoated catheters used in routine patient care.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Selection follows documented hospital protocols for routine catheterisation
2. Measured Patients: 30 patients (Convenience sample: non-blinded and non-randomised)
* 20 who receive the M4D coated catheter.
* 10 who receive the standard uncoated catheters used in routine patient care.
1\) Evaluation (5 patients, coated catheter)
A convenience sample of patients will be selected to receive the Camstent coated catheter for their routine care. These enrolments are drawn from among those recommended for routine catheterisation, for up to 28 days and in accordance to existing hospital protocols. There is no change to the routine protocols for insertion, maintenance, withdrawal, or documentation of the patient's catheterisation. Following use, the catheter is discarded according to the hospital's procedures.
Staff questionnaires will be completed to capture general use information. These will document the opinions of the nurse inserting and withdrawing the catheter, and may include questions for the patient, to record their experience. There will be no collection of patient information, and no analysis of the discarded catheter.
2\) Measurement (10 patients receiving uncoated catheters, 20 patients receiving coated catheters)
The data collection will include 10 patients who have received the standard hospital issued uncoated catheter and 20 patients who have received the Camstent coated catheter. There will be no randomisation and no blinding.
The first 10 patients needing routine urinary catheterisation to drain their bladder for up to 28 days whilst in hospital will receive the routine hospital issued catheter and will looked after by hospital and staff as standard practice.
The next 20 patients needing routine urinary catheterisation to drain their bladder whilst in hospital will receive a coated catheter. There will be no change to the intended use of the catheter for patients where it is deemed medically necessary to drain urine from the urinary bladder via the urethra using the catheter device for up to 28 days. There will be no change to any patient care or catheterisation procedures.
All 30 catheters will be sent to a laboratory for surface examination rather than immediately disposed of as medical waste. Harvested catheters will be bagged in an airtight plastic bag and tagged with a record identifier. A record identifier will be used to establish catheter traceability and duration, and will not compromise patient anonymity. The catheter will be kept refrigerated and transported to the analysis laboratory at Nottingham University within two days.
At the Nottingham Laboratory, the catheters will be subjected to qualitative and quantitative analysis to determine the percentage of biofilm coverage on the surface. This will initially be achieved using staining followed by microscopic visual examination of the catheter surface, and images taken of any surface encrustation.
For Fluorescence Microscopy, the procedure will be:
1. Cut the catheter into segments then wash three times in \~15 ml of PBS with gentle agitation.
2. Transfer the washed catheter segments into the wells of a sterile 24 well plate and stain with SYTO17 Red Fluorescent Nucleic Acid Stain.
3. Segments will be imaged using a laser scanning confocal microscope using a 10 X objective lens over a 1024 μm x 1024 μm area.
4. A z-section will be imaged (each section is 4μm apart with 36 images taken over 140μm) such that the entire curved surface is imaged. The coverage data will then be taken from a maximum intensity z-projection.
5. Data analysis will be carried out in ImageJ using the maximum intensity z-projection images.
6. Images will be converted to 8-bit greyscale images, a threshold applied to select the data correctly and the biofilm coverage measured.
7. The percentage of coverage for each sample will be computed as (Light) / (Light + Dark) \* 100%.
Aggregate descriptive statistics will be calculated, and biofilm coverage will be plotted against the duration of catheterisation as a scattergram. The study is not powered to permit statistical analysis.
Prior laboratory experiments predict that the difference in biofilm coverage could exceed 80%. If larger differences are seen in harvested catheters, then a Total Cell Count assay, in which the biofilm is sonicated free of the surface and then assessed through serial dilution, may be substituted for Fluorescence Microscopy.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
SINGLE_GROUP
Selection follows documented hospital protocols for routine catheterisation
2. Measured Patients: 30 patients (Convenience sample: non-blinded and non-randomised)
* 20 who receive the M4D coated catheter.
* 10 who receive the standard uncoated catheters used in routine patient care.
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Standard of Care
Standard of Care
Standard of Care
Standard of Care
M4D coated catheter
Experimental
M4D
Coated catheter
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
M4D
Coated catheter
Standard of Care
Standard of Care
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Patients that have or recently (within 3 weeks) had a urinary catheter, or those with signs of current urinary tract infection.
* Patients who they have had previous radiation therapy in lower pelvis.
* Patients who are cognitively impaired, or are unwilling to give consent
* Patients with a potentially immunocompromised condition
* Patients that require further antibiotics after initial dose, or those that are administered antibiotics following an infection whilst the trial urinary catheter is in situ
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Camstent Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
The James Cook University Hospital,
Middlesbrough, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PRO30CSP
Identifier Type: -
Identifier Source: org_study_id