Diagnostic Accuracy of Placental Thickness in Lower Uterine Segment Measured By Ultrasound in Prediction of Placenta Accreta Spectrum in Patients With Placenta Previa. A Diagnostic Test Accuracy Study

NCT ID: NCT05500404

Last Updated: 2022-11-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

40 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-12-01

Study Completion Date

2022-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Current prenatal diagnosis of placenta accrete spectrum disorders relies on subjective individual interpretations of visual sonographic findings on grayscale and color Doppler imaging. When blinded to clinical data, there is significant interobserver variability in the diagnosis of invasive placentation.

This study will evaluate placental thickness among pregnant women with placenta previa and determine if increased placenta thickness correlates with the risk for placenta accreta spectrum (PAS) disorders.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Placenta accreta spectrum is one of the most dangerous conditions associated with pregnancy, because hemorrhage may result in multisystem organ failure, disseminated intravascular coagulation, need for admission to an intensive care unit, hysterectomy, and even death. The reported incidence of placenta accrete spectrum disorder has increased over time and is currently between 1 in 533 to 1 in 300 pregnancies. Prior cesarean delivery and especially multiple cesarean deliveries are major risk factors. The spectrum includes placenta accreta (attachment of the placenta to myometrium without intervening decidua), placenta increta (invasion of the trophoblast into the myometrium), and placenta percreta (invasion through the myometrium, serosa, and into surrounding structures). PAS is linked to placenta previa, and there is a lot of overlap in imaging findings between the two processes. PAS problems affect approximately 11% of people with placenta previa. Differentiating between placenta previa with and without PAS problems is crucial in clinical practice. A finding of placenta previa together with a history of cesarean delivery has long been an indication for counseling patients on their risk of PAS in a current pregnancy, as the risk for placenta accreta in the presence of placenta previa increases with each subsequent cesarean delivery. Aside from cesarean deliveries and placenta previa, other risk factors have been identified for PAS, including past uterine surgeries, in vitro fertilization (IVF), multiparity, maternal age, and even female sex of the infant. Prenatal diagnosis of AIP has been shown to reduce maternal morbidity associated with this condition, most likely due to the opportunity to plan management in advance. Ultrasound is the primary investigation for prenatal diagnosis of morbidly adherent placenta, and the diagnostic accuracy is good both in retrospective, as well as prospective case series. Placental localization with transabdominal sonography (TAS) has been a standard practice for a long time. Despite its availability and noninvasive nature, accuracy of TAS may be limited by many factors, such as the posterior implantation of placenta, being obscured by the fetal head, an under-filled or over-distended bladder, and presence of blood clots, fibroids, uterine contractions, and obesity. These limitations are overcome by transvaginal sonography (TVS), which provides a better resolution by using a higher frequency transducer, shorter distance from the transducer to the internal os, and is not affected by the over- or under-filling of the bladder. Although ultrasonography's sensitivity and specificity for detecting accreta have been reported to be excellent, ranging from 80 to 90%, there was considerable difference among "experts" in predicting whether PAS was present. With placental implantation into the cesarean section scar, the center of the placental disc would be in the vicinity of the lower uterine scar. If placental implantation was near the scar but not in it, only the thinner placental margin might encroach into the lower uterine segment. The investigators therefore hypothesized that the placenta is thicker with AIP in women with a low-lying placenta or placenta previa. So, the investigators hypothesize that placental thickness will be directly related to placental invasion in cases of placenta accrete spectrum.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Placenta Accreta Spectrum

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Ultrasound measurment of placental thickness

The maximum placental thickness in the lower uterine segment will obtained using trans-abdominal ultrasound scan. For the image to be deemed suitable, a midline sagittal section of the lower uterine segment (with the implanted placenta) and the cervical canal, with the intervening urinary bladder will be required (Bhide et al., 2019). The measurement will be performed by a researcher who will be blinded to the final diagnosis.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Pregnant women with ultrasound diagnosis of placenta previa or low lying placenta
* Gestational age above 26 weeks
* singleton pregnancy
* fetal life positive
* Past history of cesarean section regardless of the number

Exclusion Criteria

* Hemodynamically unstable women.
* Patients with pregestational or gestational DM.
* Multiple gestation.
* Medical disorders which can lead to uteroplacental insufficiency (preeclampsia - SLE - antiphospholipid antibody syndrome).
* Any condition which can lead to enlarged placenta such as fetal hydrops
Minimum Eligible Age

20 Years

Maximum Eligible Age

40 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ain Shams Maternity Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ahmed Mohammed Elmaraghy

Lecturer

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ahmed M Mamdouh, MD

Role: STUDY_DIRECTOR

Ainshams university maternity hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

AinShams university maternity hospital

Cairo, , Egypt

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Egypt

References

Explore related publications, articles, or registry entries linked to this study.

Silver RM, Branch DW. Placenta Accreta Spectrum. N Engl J Med. 2018 Apr 19;378(16):1529-1536. doi: 10.1056/NEJMcp1709324. No abstract available.

Reference Type BACKGROUND
PMID: 29669225 (View on PubMed)

Li Y, Choi HH, Goldstein R, Poder L, Jha P. Placental thickness correlates with placenta accreta spectrum (PAS) disorder in women with placenta previa. Abdom Radiol (NY). 2021 Jun;46(6):2722-2728. doi: 10.1007/s00261-020-02894-9. Epub 2021 Jan 2.

Reference Type BACKGROUND
PMID: 33388802 (View on PubMed)

Jauniaux E, Collins S, Burton GJ. Placenta accreta spectrum: pathophysiology and evidence-based anatomy for prenatal ultrasound imaging. Am J Obstet Gynecol. 2018 Jan;218(1):75-87. doi: 10.1016/j.ajog.2017.05.067. Epub 2017 Jun 24.

Reference Type BACKGROUND
PMID: 28599899 (View on PubMed)

Morgan EA, Sidebottom A, Vacquier M, Wunderlich W, Loichinger M. The effect of placental location in cases of placenta accreta spectrum. Am J Obstet Gynecol. 2019 Oct;221(4):357.e1-357.e5. doi: 10.1016/j.ajog.2019.07.028. Epub 2019 Jul 22.

Reference Type BACKGROUND
PMID: 31344349 (View on PubMed)

Bhide A, Laoreti A, Kaelin Agten A, Papageorghiou A, Khalil A, Uprichard J, Thilaganathan B, Chandraharan E. Lower uterine segment placental thickness in women with abnormally invasive placenta. Acta Obstet Gynecol Scand. 2019 Jan;98(1):95-100. doi: 10.1111/aogs.13422. Epub 2018 Aug 2.

Reference Type BACKGROUND
PMID: 29978457 (View on PubMed)

Petpichetchian C, Pranpanus S, Suntharasaj T, Kor-Anantakul O, Hanprasertpong T. Comparison of transabdominal and transvaginal sonography in the diagnosis of placenta previa. J Clin Ultrasound. 2018 Jul;46(6):386-390. doi: 10.1002/jcu.22600. Epub 2018 Apr 25.

Reference Type BACKGROUND
PMID: 29693718 (View on PubMed)

Elmaraghy AM, Taha Fayed S, Abd ElHamid Ali M, Ali Hassanien M, Mohamed Mamdouh A. Diagnostic Accuracy of Placental Thickness in Lower Uterine Segment Measured by Ultrasound in Prediction of Placenta Accreta Spectrum in Patients with Placenta Previa. A Diagnostic Test Accuracy Study. Int J Womens Health. 2023 Feb 16;15:311-320. doi: 10.2147/IJWH.S399520. eCollection 2023.

Reference Type DERIVED
PMID: 36814526 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

5

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Accuracy of Rail Sign at Detection of PAS
NCT07159997 NOT_YET_RECRUITING NA