Validity and Reliability of a Clinical Method for Assessment of Cardiorespiratory Fitness Using Seismocardiography
NCT ID: NCT05356871
Last Updated: 2024-02-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
20 participants
OBSERVATIONAL
2020-06-29
2020-11-02
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Biological age is a concept trying to relate the age to the health status rather than the date of birth. Biological age assesses the heterogeneity in functional metabolic status and vulnerability to disease. A Biological age model has previously been designed for health promotion interventions. However, reliability assessment of the model is needed.
The purpose of the current study was therefore to:
1. investigate the validity and reliability of a new clinical method for estimation of maximal oxygen consumption (VO2max) using seismocardiography.
2. investigate the reliability of the biological age model.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Validity of Measuring Preoperative Fitness Using Seismofit
NCT05943730
Estimating Peak Oxygen Uptake in People Living With Coronary Heart Disease
NCT05505344
Verification Protocol for the Cloud DX Vitaliti Continuous Vital Signs Monitor (VERDICT-2)
NCT05886153
Study on Cardiac Output Evaluation Based on Wearable Monitoring Data
NCT06938893
Observational, Non-Interventional Study Supporting Validation of VO2Max Estimation Methods Using Results in Patients Receiving Standard of Care Cardiopulmonary Exercise Tests (CPET)
NCT05678530
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The participants received both written and oral information about the study and the possible risks associated hereof, before volunteering and signing a written informed consent form.
The participants arrived at the laboratory after an overnight fast from latest 10pm the day before (water excepted). Furthermore, the participants were asked to avoid strenuous exercise 48 hours prior to the test day and eat a habitual diet, which had to be replicated before the second and third visit.
Testing at each visit to the laboratory included:
Completion of a short version of the International Physical Activity Questionaire, about leisure time physical activities.
Measurements of height, weight and waist and hip circumference.
Measurement of body composition using a Dual-energy X-ray absorptiometry (DXA) scan on day 1.
Measurement of body composition using a bioelectrical impedance analysis scale on day 1, 2 and 3.
Measurement of blood pressure in the supine position. 3 measures with 2 minute resting in between.
Measurement of VO2max using a non-exercise testing method based on seismocardiography.
Collection of a 15 ml resting venous blood sample for measurements of resting levels of hormones, metabolites and lipids in the blood plasma.
Measurement of lung function in terms of FEV1 and FVC (Vyntus SPIRO spirometer, Vyaire Medical).
Determination of VO2max applying a graded exercise test on a bicycle ergometry until voluntary exhaustion with continuous pulmonary gas exchange measurements.
Procedure and analysis:
Bioelectrical impedance analysis scale (Tanita MC-780MA, Tanita Corporation of America Inc): The participants was analysed on the scale after voiding and wearing minimal clothing.
DXA scanning (Lunar iDXA, GE Healthcare): The participants was placed in the supine position in the DXA scanner after voiding and while wearing minimal clothing.
Blood samples: The blood samples was collected from the vein cubiti medialis in the forearm. The blood was sampled in iced BD vacutainers (5 mL Aprotinin, 4 mL EDTA and 2 mL Lithium Heparin) and immediately centrifuged at 4000 g for 10 minutes at 4⁰C (Rotina 380R, Hettich). The plasma was collected and stored at -80⁰C for later analyzes of resting levels of metabolites, lipids and hormones.
The concentrations of hemoglobin, hematocrit, glucose and lactate was immediately analyzed though sampling of 2 mL blood in a specialized syringe (safePICO Aspirator, Radiometer) and using an automatic analyzer (ABL800 Flex, Radiometer).
SCG VO2max prediction:
The SCG VO2max prediction was performed as previously described with the same type of equipment. Brief, the SCG recording was performed using an iWorx IX-228/s (IWORX, Dover, New Hampshire) connected to a PC. LabScribe was used as recording software (version 3. Dover, New Hampshire). The accelerometer (Silicon Design 1521-002) had a resolution of ± 2 g, a low noise at 7 μg / √ Hz and a frequency 70 response of 0-300 Hz and was placed on sternum 2 cm proximal of processus xiphoideus. The recording lasted 5 minutes and was performed in the supine position. VentriJect Aps later performed the signal processing and VO2max estimation. VentriJect Aps was informed of the age, height and weight of the participants for inclusion in the prediction model, but was blinded of the measured VO2max.
Hereafter a new devolved wireless device (Seismofit, VentriJect Aps) was used to determine SCG VO2max. The Seismofit contains a 3v battery and a three-axis digital output accelerometer (LIS3DHH, ST Microelectronics). The Seismofit device is connected to a phone application where the participants demographic data (age, height and weight) was entered before performing the recording. For the recording, the participants was lying in the supine position and the Seismofit device was placed on sternum 2 cm proximal of processus Xiphoideus with double adhesive tape. The predicted SCG VO2max value appeared on the phone screen within 5 minutes.
The Seismofit VO2max prediction was performed twice with 5 minutes rest in between. This was done to assess the test-retest reliability of the device.
The iWorx VO2max was done to compare the previous equipment with the new wireless equipment with automatic signal processing.
The gold standard VO2max determination:
A graded exercise test (GET) until voluntary exhaustion on a bicycle ergometer was performed. The protocol consisted of a five-minute warm-up at 80 W for women and 100 W for men and increased hereafter with 20 W for women and 25 W for men every minute until exhaustion.
Participants was wearing a chest strapped heart rate monitor (Polar Vantage XL, Polar) with continuous heart rate measures during the test. Furthermore the participants, was asked about perceived exhaustion on the 6-20 Borg scale directly following exhaustion.
Statistical analysis:
All data was checked for normal distribution (Shapiro-Wilk test) and equal variance (Brown- Forsythe test). The significant level is p\<0.05.
A Mixed-effect model, Bland-Altman analysis with 95% limits of agreement, Pearson correlations and Mean Absolute Percentage Error was used for assessment of validity between the Seismofit VO2max and GET VO2max, Seismofit VO2max measure 1 and 2 and between Seismofit VO2max and iWorx VO2max.
Coefficient of Variation (CV), Standard Error of Estimate (SEE) and Intraclass Correlation Coefficient (ICC) was used to assess reliability of VO2max measurements.
The project was approved by the Science Ethical commitee of the greater region of Copenhagen (H-19081375) the 3rd of February 2020. The protocol of the study adhered to the principles of the Helsinki declaration.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Healthy participants
Healthy men and women within the age of 18 and 75 yrs.
VO2max validity and reliability assesment
Reliability assessment of VO2max determination with three repeated measures for two methods.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
VO2max validity and reliability assesment
Reliability assessment of VO2max determination with three repeated measures for two methods.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Pregnancy
* Conditions that prevent maximal cycling exercise
18 Years
75 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
VentriJect ApS
INDUSTRY
University of Copenhagen
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Jørn Wulff Helge
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jørn W Helge, Professor
Role: PRINCIPAL_INVESTIGATOR
Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Xlab, Faculty of Health and Medical Sciences, University of Copenhagen
Copenhagen, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Sorensen K, Schmidt SE, Jensen AS, Sogaard P, Struijk JJ. Definition of Fiducial Points in the Normal Seismocardiogram. Sci Rep. 2018 Oct 18;8(1):15455. doi: 10.1038/s41598-018-33675-6.
Sorensen K, Poulsen MK, Karbing DS, Sogaard P, Struijk JJ, Schmidt SE. A Clinical Method for Estimation of VO2max Using Seismocardiography. Int J Sports Med. 2020 Sep;41(10):661-668. doi: 10.1055/a-1144-3369. Epub 2020 May 26.
Hansen MT, Grønfeldt BM, Rømer T, Fogelstrøm M, Sørensen K, Schmidt SE, et al. Determination of Maximal Oxygen Uptake Using Seismocardiography at Rest. In: Computing in Cardiology 2021. IEEE. 2021;48(1):48-51 DOI: 10.22489/CinC.2021.165
Husted KLS, Fogelstrom M, Hulst P, Brink-Kjaer A, Henneberg KA, Sorensen HBD, Dela F, Helge JW. A Biological Age Model Designed for Health Promotion Interventions: Protocol for an Interdisciplinary Study for Model Development. JMIR Res Protoc. 2020 Oct 26;9(10):e19209. doi: 10.2196/19209.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
VentriJect Validation Study
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.