Effect of High-Flow Nasal Cannula on IVC Measurements Using Point of Care Ultrasound

NCT ID: NCT05264454

Last Updated: 2024-08-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Clinical Phase

NA

Study Classification

INTERVENTIONAL

Study Start Date

2022-07-01

Study Completion Date

2023-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The size of the inferior vena cava (IVC) using point of care ultrasound is used in resuscitation of patients who are critically ill and is now being used as a standard part of resuscitation in many clinical situations. Multiple factors can effect the size of the IVC including the type of oxygen devices the patient is currently on. In the ICU setting, the use of High Flow Nasal Cannula (HFNC) is often used to help in patients who are critically ill. There is some evidence to suggest that the use of HFNC can effect the size of the IVC measurement but the extent of the effect has not been well characterized. The purpose of this study is to determine the effect HFNC has on the size of the IVC measured using a point of care ultrasound.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Shock is a state of decreased perfusion and inadequate oxygen delivery to tissues. This results in end organ damage and is associated with high morbidity and mortality, regardless of etiology. Shock associated with an infection is known as septic shock. In the intensive care unit (ICU) population, septic shock is the most common admission to the ICU and, with a mortality rate approaching 30%, is one of the leading causes of death. Early antibiotics and early intravenous fluid administration are a key component of resuscitation, but over-resuscitation with fluids is associated with adverse outcomes, including death. Therefore, methods to determine the ideal amount of fluid to administer are required.

Increasingly, the use of a bedside ultrasound, known as point of care ultrasound (PoCUS), can be used to determine the cause of shock and to help guide the ideal amount of fluid administration. One method for determining the appropriate amount of fluid to administer is the measurement of the size of the inferior vena cava (IVC). The IVC is a large vein that travels through the abdomen and delivers blood back to the heart. In a breathing patient, the size of the IVC varies with the breathing cycle. During inspiration the contraction of the diaphragm results in the generation of a negative pressure inside the chest cavity. This pressure change results in a decrease in size of the IVC during inspiration; contrary, during expiration, the IVC will be maximally distended. One of the best methods for determining fluid responsiveness using IVC is known as the IVC collapsibility index, which is defined as the \[(Maximum diameter IVC-Minimum diameter) / Maximum diameter IVC\] x 100. If the index is greater than 41% (range, 40%-42%), the LR ranged from 3.5 (95% CI, 1.1-15) to 9.3 (95% CI, 0.88-51) that the patient would respond to fluid.

One limitation to the use of PoCUS to assess the IVC is that the size of the vessel is affected by pressure inside the chest cavity. For example, patients who have obstructive sleep apnea (OSA) are often treated using a device called a continuous positive airway pressure (CPAP) machine. CPAP works by applying a constant amount of air pressure to prevent the soft tissues in the neck from collapsing and obstructing the airway. This constant pressure results in an increase of the chest cavity pressure which has been shown to increase the IVC diameter and a decreased IVC collapsibility index. This could result in an error in not administering fluid when the patient would benefit from it.

A patient population where this error may occur are those admitted to hospital with pneumonia. Pneumonia is the most common presentation of septic shock in critical care. Often times these patients present with septic shock as well as respiratory failure, which is treated with supplemental oxygen. Increasingly, high flow nasal cannulas (HFNC) have been used in the initial management of respiratory failure. Studies in the critically ill populations have demonstrated that, compared to conventional oxygen therapy, HFNC provides superior oxygenation and decreases the need for intubation. HFNC is a device that is able to generate very high flows (up to 60 L/min) at an adjustable FiO2 such that even at very high peak inspiratory flows (i.e. breathing in quickly), FiO2 remains consistent. These high flows generate a CPAP effect, with an approximately linear relationship of 1 cmH2O for every 10 L/min of flow. Therefore, it is possible that patients who are placed on HFNC may have an artificially enlarged IVC measurement by ultrasound.

Considering the increasing scope and utilization of PoCUS as well as HFNC in the treatment of respiratory failure, it is important to establish what effect HFNC has on POCUS IVC measurements. To date, only one study has examined the effect of HFNC on the size of IVC. This study was conducted in heart failure patients where the patients were all volume overloaded (distended IVC). The study placed patients in heart failure on HFNC on flows of 20 and 40L/min which resulted in a decrease in the IVC collapsibility index. However, no study has examined the effect of HFNC non-volume overloaded patients at 60L /min.

Our hypothesis is that the application of HFNC will increase in the size of the IVC and decrease the IVC collapsibility index in healthy patients.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Fluid Overload

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

SINGLE

Outcome Assessors
intervention will be blinded to those assessing the size of the IVC

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

0 L

This will be the arm where the baseline IVC assessment size is conducted at

Group Type PLACEBO_COMPARATOR

high flow nasal cannulae

Intervention Type DEVICE

The plan is to examine the effects of the size of the IVC size based upon varrying levels of high flow nasal cannulae flow

30 L

The HFNC flow will be set at 30 L / min. The IVC size will then be assessed using a POCUS

Group Type ACTIVE_COMPARATOR

high flow nasal cannulae

Intervention Type DEVICE

The plan is to examine the effects of the size of the IVC size based upon varrying levels of high flow nasal cannulae flow

60 L

The HFNC flow will be set at 60 L / min. The IVC size will then be assessed using a POCUS

Group Type ACTIVE_COMPARATOR

high flow nasal cannulae

Intervention Type DEVICE

The plan is to examine the effects of the size of the IVC size based upon varrying levels of high flow nasal cannulae flow

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

high flow nasal cannulae

The plan is to examine the effects of the size of the IVC size based upon varrying levels of high flow nasal cannulae flow

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

point of care ultrasound

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Ambulatory
* 18-40 years old

Exclusion Criteria

* Severe lung disease (e.g. poorly controlled asthma, COPD with FEV1 \<40%)
* Congestive heart failure (diastolic dysfunction, ejection fraction \< 50%, severe valvular disorders)
* Renal failure
* Complete nasal obstruction or facial deformities
* BMI \> 30
* Pregnancy
Minimum Eligible Age

18 Years

Maximum Eligible Age

40 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nova Scotia Health Authority

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

QEII Health Sciences Centre

Halifax, Nova Scotia, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2014 Feb 6;370(6):583. doi: 10.1056/NEJMc1314999. No abstract available.

Reference Type BACKGROUND
PMID: 24499231 (View on PubMed)

Angus DC, van der Poll T. Severe sepsis and septic shock. N Engl J Med. 2013 Aug 29;369(9):840-51. doi: 10.1056/NEJMra1208623. No abstract available.

Reference Type BACKGROUND
PMID: 23984731 (View on PubMed)

Angus DC, Linde-Zwirble WT, Lidicker J, Clermont G, Carcillo J, Pinsky MR. Epidemiology of severe sepsis in the United States: analysis of incidence, outcome, and associated costs of care. Crit Care Med. 2001 Jul;29(7):1303-10. doi: 10.1097/00003246-200107000-00002.

Reference Type BACKGROUND
PMID: 11445675 (View on PubMed)

Navaneelan T. Deaths involving sepsis in Canada. Health at a Glance. 2016;(82):11.

Reference Type BACKGROUND

Mayr FB, Yende S, Angus DC. Epidemiology of severe sepsis. Virulence. 2014 Jan 1;5(1):4-11. doi: 10.4161/viru.27372. Epub 2013 Dec 11.

Reference Type BACKGROUND
PMID: 24335434 (View on PubMed)

Marik PE, Linde-Zwirble WT, Bittner EA, Sahatjian J, Hansell D. Fluid administration in severe sepsis and septic shock, patterns and outcomes: an analysis of a large national database. Intensive Care Med. 2017 May;43(5):625-632. doi: 10.1007/s00134-016-4675-y. Epub 2017 Jan 27.

Reference Type BACKGROUND
PMID: 28130687 (View on PubMed)

Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, Kumar A, Sevransky JE, Sprung CL, Nunnally ME, Rochwerg B, Rubenfeld GD, Angus DC, Annane D, Beale RJ, Bellinghan GJ, Bernard GR, Chiche JD, Coopersmith C, De Backer DP, French CJ, Fujishima S, Gerlach H, Hidalgo JL, Hollenberg SM, Jones AE, Karnad DR, Kleinpell RM, Koh Y, Lisboa TC, Machado FR, Marini JJ, Marshall JC, Mazuski JE, McIntyre LA, McLean AS, Mehta S, Moreno RP, Myburgh J, Navalesi P, Nishida O, Osborn TM, Perner A, Plunkett CM, Ranieri M, Schorr CA, Seckel MA, Seymour CW, Shieh L, Shukri KA, Simpson SQ, Singer M, Thompson BT, Townsend SR, Van der Poll T, Vincent JL, Wiersinga WJ, Zimmerman JL, Dellinger RP. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Intensive Care Med. 2017 Mar;43(3):304-377. doi: 10.1007/s00134-017-4683-6. Epub 2017 Jan 18.

Reference Type BACKGROUND
PMID: 28101605 (View on PubMed)

National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network; Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006 Jun 15;354(24):2564-75. doi: 10.1056/NEJMoa062200. Epub 2006 May 21.

Reference Type BACKGROUND
PMID: 16714767 (View on PubMed)

Chaves RCF, Correa TD, Neto AS, Bravim BA, Cordioli RL, Moreira FT, Timenetsky KT, de Assuncao MSC. Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature. Ann Intensive Care. 2018 Feb 9;8(1):21. doi: 10.1186/s13613-018-0365-y.

Reference Type BACKGROUND
PMID: 29427013 (View on PubMed)

Perera P, Mailhot T, Riley D, Mandavia D. The RUSH exam: Rapid Ultrasound in SHock in the evaluation of the critically lll. Emerg Med Clin North Am. 2010 Feb;28(1):29-56, vii. doi: 10.1016/j.emc.2009.09.010.

Reference Type BACKGROUND
PMID: 19945597 (View on PubMed)

Bentzer P, Griesdale DE, Boyd J, MacLean K, Sirounis D, Ayas NT. Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids? JAMA. 2016 Sep 27;316(12):1298-309. doi: 10.1001/jama.2016.12310.

Reference Type BACKGROUND
PMID: 27673307 (View on PubMed)

Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, Quintard H, Leone M, Zoric L, Lefrant JY; AzuRea group. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012 Oct 8;16(5):R188. doi: 10.1186/cc11672.

Reference Type BACKGROUND
PMID: 23043910 (View on PubMed)

Airapetian N, Maizel J, Alyamani O, Mahjoub Y, Lorne E, Levrard M, Ammenouche N, Seydi A, Tinturier F, Lobjoie E, Dupont H, Slama M. Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients? Crit Care. 2015 Nov 13;19:400. doi: 10.1186/s13054-015-1100-9.

Reference Type BACKGROUND
PMID: 26563768 (View on PubMed)

Rudski LG, Lai WW, Afilalo J, Hua L, Handschumacher MD, Chandrasekaran K, Solomon SD, Louie EK, Schiller NB. Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2010 Jul;23(7):685-713; quiz 786-8. doi: 10.1016/j.echo.2010.05.010. No abstract available.

Reference Type BACKGROUND
PMID: 20620859 (View on PubMed)

Jenkinson C, Davies RJ, Mullins R, Stradling JR. Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial. Lancet. 1999 Jun 19;353(9170):2100-5. doi: 10.1016/S0140-6736(98)10532-9.

Reference Type BACKGROUND
PMID: 10382693 (View on PubMed)

Au SY, Lau CL, Chen KK, Cheong AP, Tong YT, Chan LK. Hemodynamic Effects of Noninvasive Positive-Pressure Ventilation Assessed Using Transthoracic Echocardiography. J Cardiovasc Echogr. 2018 Apr-Jun;28(2):114-119. doi: 10.4103/jcecho.jcecho_53_17.

Reference Type BACKGROUND
PMID: 29911008 (View on PubMed)

Lee CC, Mankodi D, Shaharyar S, Ravindranathan S, Danckers M, Herscovici P, Moor M, Ferrer G. High flow nasal cannula versus conventional oxygen therapy and non-invasive ventilation in adults with acute hypoxemic respiratory failure: A systematic review. Respir Med. 2016 Dec;121:100-108. doi: 10.1016/j.rmed.2016.11.004. Epub 2016 Nov 3.

Reference Type BACKGROUND
PMID: 27888983 (View on PubMed)

Parke RL, Bloch A, McGuinness SP. Effect of Very-High-Flow Nasal Therapy on Airway Pressure and End-Expiratory Lung Impedance in Healthy Volunteers. Respir Care. 2015 Oct;60(10):1397-403. doi: 10.4187/respcare.04028. Epub 2015 Sep 1.

Reference Type BACKGROUND
PMID: 26329355 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HFNCIVC1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Ultrasound-Guided BCV and IJV in ICU Patients
NCT07062068 NOT_YET_RECRUITING NA