Accuracy Evaluation of EarlySense With Modified Sensor (Smaller Shape Sensor With BLE) at Home Setting Monitoring a Subject While Partner in Bed

NCT ID: NCT05237518

Last Updated: 2022-07-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

36 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-04-30

Study Completion Date

2024-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Accuracy evaluation of EarlySense device, a smaller shape sensor with BLE connection to processing unit (HUB)) for use while two people are in bed ("Home Use" scenario) The EarlySense device is intended for continuous contact-free monitoring of heart rate and respiration rate at home, or in professional healthcare settings. The system is intended for remote monitoring of patients by healthcare professionals and is indicated mainly for elderly population monitoring.

The modified version of this product which is the subject of this validation study allows monitoring of subjects when there is a second person in the same bed ("Home scenario" environment). The objective of this study is to evaluate the accuracy of the device in determining Respiration Rate (Br./min) and Heart Rate (BPM) at home environment, while two people are in the same double bed. The study aims to demonstrate that partner presence doesn't affect the monitoring accuracy of the subject that is being measured.

The continuous monitoring will last for duration of 90 minutes for each subject, unless the participant requests termination of the experiment or as per the physician's instructions. Subjects admitted to the study will be monitored using both Capnography and ECG- as reference devices. The EarlySense revised sensor will be placed under one of the two-mattress types incorporated into the study. Both mattresses are typical double bed mattresses of 160 X 200 cm with two different internal structure composition. The sensor will be placed directly below the subject's thorax area on one of the mattress sides. The signals collected by the sensor will be communicated via BLE to the processing unit (HUB).

Following connecting the subject to the reference devices, both the subject and the partner will be instructed on the actions they should perform through the stages of the experiment.

The subject will lie on the mattress side where the EarlySense sensor is located, while the partner will be instructed to enter the other side of the mattress. At this time, the experiment will start, and the clock will start running.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Sleep Disorder

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

36 adults

The test group should include both men and women subjects. Two equal sizes (18) sub-groups will be enrolled such that each sub-group will be monitored while lying on a different mattress type.

Group Type OTHER

EarlySense Noomi system

Intervention Type DEVICE

The EarlySense device is intended for continuous contact-free monitoring of heart rate and respiration rate at home, or in professional healthcare settings. The system is intended for remote monitoring of patients by healthcare professionals and is indicated mainly for elderly population monitoring.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

EarlySense Noomi system

The EarlySense device is intended for continuous contact-free monitoring of heart rate and respiration rate at home, or in professional healthcare settings. The system is intended for remote monitoring of patients by healthcare professionals and is indicated mainly for elderly population monitoring.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

EarlySense™ device

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age above 18 years
* Sleeping with a partner in bed
* Willing to sign the consent form

Exclusion Criteria

* Subjects with arrhythmia will be excluded from the study
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

EarlySense Ltd.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ES-CLC-2022-001

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Sleep Health in Pregnant Women in ENRICH
NCT07216287 NOT_YET_RECRUITING
Nyx3 Data Collection Study
NCT07099183 NOT_YET_RECRUITING